Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 18:506-511
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hanet, C
Right arrow Articles by Schroeder, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hanet, C
Right arrow Articles by Schroeder, E

Influence of balloon size and stenosis morphology on immediate and delayed elastic recoil after percutaneous transluminal coronary angioplasty

C Hanet, W Wijns, X Michel, and E Schroeder

Division of Cardiology, University of Louvain Medical School, Brussels, Belgium.

After successful coronary angioplasty, the minimal luminal diameter of the dilated coronary artery segment is generally smaller than the diameter of the largest balloon catheter at the maximal inflation pressure. The determinants of this phenomenon were studied in 28 patients. Biplane angiograms were obtained after intracoronary administration of isosorbide dinitrate (1 mg) before, immediately and 24 h after coronary angioplasty. Balloon and coronary luminal diameters were measured by automated contour detection. Immediately after the procedure, the difference between inflated balloon diameter and minimal luminal diameter averaged 0.93 +/- 0.43 mm for the entire group and was greater both in eccentric stenoses (1.13 +/- 0.39 vs. 0.70 +/- 0.36 mm; p less than 0.01) and after angioplasty with an oversized balloon (1.20 +/- 0.37 vs. 0.71 +/- 0.33 mm; p less than 0.005). At 24 h, the balloon - minimal luminal diameter difference was unchanged at the group level (0.86 +/- 0.38 mm, but the minimal luminal diameter increased significantly in the subgroup of coronary segments dilated with an oversized balloon (1.97 +/- 0.37 vs. 1.81 +/- 0.28 mm; p less than 0.05). Thus, the difference between the minimal diameter of a dilated coronary segment immediately after a successful coronary balloon angioplasty procedure and the maximal diameter of the inflated balloon catheter is dependent both on eccentricity of the stenosis and on the balloon/artery diameter ratio. Moreover, the increase in minimal luminal diameter 24 h after angioplasty performed with an oversized balloon suggest that in addition to elastic recoil partly reversible factors related to vessel barotrauma are involved.


This article has been cited by other articles:


Home page
CirculationHome page
G. W. Stone, J. M. Hodgson, F. G. St Goar, A. Frey, H. Mudra, H. Sheehan, and T. J. Linnemeier
Improved Procedural Results of Coronary Angioplasty With Intravascular Ultrasound Guided Balloon Sizing : The CLOUT Pilot Trial
Circulation, April 15, 1997; 95(8): 2044 - 2052.
[Abstract] [Full Text]


Home page
CirculationHome page
M. Haude, G. Caspari, D. Baumgart, R. Brennecke, J. Meyer, and R. Erbel
Comparison of Myocardial Perfusion Reserve Before and After Coronary Balloon Predilatation and After Stent Implantation in Patients With Postangioplasty Restenosis
Circulation, August 1, 1996; 94(3): 286 - 297.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement