Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 17:1357-1359
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wladimiroff, J.
Right arrow Articles by Stewart, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wladimiroff, J.
Right arrow Articles by Stewart, P.

Fetal cardiac flow velocities in the late 1st trimester of pregnancy: a transvaginal Doppler study

JW Wladimiroff, TW Huisman, and PA Stewart

Department of Obstetrics and Gynecology, Academic Hospital Dijkzigt, Rotterdam, The Netherlands.

In 30 normal women with a singleton pregnancy, transvaginal Doppler ultrasound was used to record flow velocity at the fetal atrioventricular (AV) valve and outflow tract levels (ascending aorta and pulmonary artery) at 11 to 13 weeks of gestation. Technically acceptable flow velocity waveforms were recorded at the AV valve level in 19 fetuses and in the ascending aorta and pulmonary artery in 15 and 17 fetuses, respectively. Successful documentation of both transmitral and transtricuspid flow velocity waveforms was achieved in six fetuses only. Peak velocities during atrial contraction (A wave) were nearly twice as high as those during early diastolic filling (E wave), reflecting low ventricular compliance. Peak and time-averaged flow velocities in the outflow tract were lower than those observed in 2nd and 3rd trimester pregnancies with mean values of 32.1 +/- 5.4 (+/- SD) and 11.2 +/- 2.2 cm/s, respectively, in the ascending aorta and 29.6 +/- 5.1 and 10.8 +/- 2.1 cm/s in the pulmonary artery.


This article has been cited by other articles:


Home page
HeartHome page
K Makikallio, P Jouppila, and J Rasanen
Human fetal cardiac function during the first trimester of pregnancy
Heart, March 1, 2005; 91(3): 334 - 338.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Srinivasan, H. S. Baldwin, O. Aristizabal, L. Kwee, M. Labow, M. Artman, and D. H. Turnbull
Noninvasive, In Utero Imaging of Mouse Embryonic Heart Development With 40-MHz Echocardiography
Circulation, September 1, 1998; 98(9): 912 - 918.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. van Splunder, T. Stijnen, and J. W. Wladimiroff
Fetal Atrioventricular Flow-Velocity Waveforms and Their Relation to Arterial and Venous Flow-Velocity Waveforms at 8 to 20 Weeks of Gestation
Circulation, September 15, 1996; 94(6): 1372 - 1378.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement