JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1991; 17:985-990
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hook, B.
Right arrow Articles by Marchlinski, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hook, B.
Right arrow Articles by Marchlinski, F.

Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapy

BG Hook and FE Marchlinski

Clinical Electrophysiology Laboratory, Hospital of the University of Pennsylvania, Philadelphia 19104.

An antitachycardia pacemaker-cardioverter-defibrillator that is capable of storing ventricular electrograms before and after delivery of device shock therapy was implanted in 16 patients. Three of the patients experienced out-of-hospital device shock therapy preceded by minimal symptoms. Although limitations of electrogram analysis exist and are discussed, careful analysis and registration of electrograms during all supraventricular and ventricular rhythms observed during in-hospital testing served as an important reference for subsequent arrhythmia diagnosis. By analyzing the electrogram rate and RR interval stability and configuration, a definitive diagnosis was established in all three patients (atrial fibrillation, polymorphic ventricular tachycardia and rate-sensing lead disruption, respectively). Thus, the ability to store ventricular electrograms before shock therapy represents a major advance in the management of patients who receive an electrical device to treat ventricular tachyarrhythmia.


This article has been cited by other articles:


Home page
EuropaceHome page
J. L. Rojo-Alvarez, A. Arenal, A. Garcia-Alberola, M. Ortiz, M. Valdes, and A. Artes-Rodriguez
A new algorithm for rhythm discrimination in cardioverter defibrillators based on the initial voltage changes of the ventricular electrogram
Europace, January 1, 2003; 5(1): 77 - 82.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
Committee Members, G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, et al.
ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices--Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
J. Am. Coll. Cardiol., November 6, 2002; 40(9): 1703 - 1719.
[Full Text] [PDF]


Home page
CirculationHome page
G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, M. J. Silka, et al.
ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
Circulation, October 15, 2002; 106(16): 2145 - 2161.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. Grimm, J.u. Hoffmann, H.-H. Muller, and B. Maisch
Implantable defibrillator event rates in patients with idiopathic dilated cardiomyopathy, nonsustained ventricular tachycardia on Holter and a left ventricular ejection fraction below 30%
J. Am. Coll. Cardiol., March 6, 2002; 39(5): 780 - 787.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T.-M. Lu, C.-T. Tai, M.-H. Hsieh, C.-F. Tsai, Y.-K. Lin, W.-C. Yu, H.-M. Tsao, S.-H. Lee, Y.-A. Ding, M.-S. Chang, et al.
Electrophysiologic characteristics in initiation of paroxysmal atrial fibrillation from a focal area
J. Am. Coll. Cardiol., May 1, 2001; 37(6): 1658 - 1664.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
D. S. Cannom and E. N. Prystowsky
Management of Ventricular Arrhythmias: Detection, Drugs, and Devices
JAMA, January 13, 1999; 281(2): 172 - 179.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Ruppel, C. A. Schluter, S. Boczor, T. Meinertz, M. Schluter, K.-H. Kuck, and R. Cappato
Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1724 - 1730.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. M. Grubman, B. B. Pavri, T. Shipman, N. Britton, and D. Z. Kocovic
Cardiac death and stored electrograms in patients with third-generation implantable cardioverter-defibrillators
J. Am. Coll. Cardiol., October 1, 1998; 32(4): 1056 - 1062.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. Grimm, J.u. Hoffmann, V. Menz, K. Luck, and B. Maisch
Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia
J. Am. Coll. Cardiol., September 1, 1998; 32(3): 739 - 745.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. D. Swerdlow, C. T. Peter, R. M. Kass, E. S. Gang, W. J. Mandel, C. Hwang, D. J. Martin, and P.-S. Chen
Programming of Implantable Cardioverter-Defibrillators on the Basis of the Upper Limit of Vulnerability
Circulation, March 18, 1997; 95(6): 1497 - 1504.
[Abstract] [Full Text]


Home page
CirculationHome page
M. Nair, N. Saoudi, D. Kroiss, and B. Letac
Automatic Arrhythmia Identification Using Analysis of the Atrioventricular Association: Application to a New Generation of Implantable Defibrillators
Circulation, February 18, 1997; 95(4): 967 - 973.
[Abstract] [Full Text]


Home page
CirculationHome page
A. E. Epstein, W. M. Miles, D. G. Benditt, A. J. Camm, E. J. Darling, P. L. Friedman, A. Garson, J. C. Harvey, G. A. Kidwell, G. J. Klein, et al.
Personal and Public Safety Issues Related to Arrhythmias That May Affect Consciousness: Implications for Regulation and Physician Recommendations: A Medical/Scientific Statement From the American Heart Association and the North American Society of Pacing and Electrophysiology
Circulation, September 1, 1996; 94(5): 1147 - 1166.
[Full Text]


Home page
CirculationHome page
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation, September 15, 1995; 92(6): 1651 - 1664.
[Abstract] [Full Text]


Home page
CirculationHome page
A. M. Gillis, R. S. Sheldon, D. G. Wyse, J. W. Leitch, R. Yee, G. J. Klein, H. J. Duff, and L. B. Mitchell
Long-term Reproducibility of Ventricular Tachycardia Induction in Patients With Implantable Cardioverter/Defibrillators : Serial Noninvasive Studies
Circulation, May 15, 1995; 91(10): 2605 - 2613.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1991 by the American College of Cardiology Foundation.