JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1991; 17:485-491
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McKay, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McKay, R.

The Mansfield Scientific Aortic Valvuloplasty Registry: overview of acute hemodynamic results and procedural complications

RG McKay

Cardiac Laboratory, Hartford Hospital, Connecticut 06115.

Between December 1, 1986 and October 30, 1987, balloon aortic valvuloplasty was performed in 492 patients with aortic stenosis (mean age 79 +/- 8.4 years) enrolled in the Mansfield Scientific Aortic Valvuloplasty Registry. All procedures were performed from a femoral approach (92%), brachial approach (6%) or transseptal approach (2%) and utilized either a single balloon technique (72%) or a double balloon technique (28%). Valvuloplasty resulted in a significant improvement in aortic valve area (0.50 +/- 0.18 cm2 to 0.82 +/- 0.30 cm2), mean aortic valve gradient (60 +/- 23 mm Hg to 30 +/- 13 mm Hg) and cardiac output (3.86 +/- 1.26 to 4.05 +/- 1.31 liters/min). Serial aortography demonstrated a moderate or severe increase in aortic insufficiency in only 2.1% of patients. Statistical analysis of the procedural factors affecting acute valvuloplasty results demonstrated significant correlations of single versus double balloon technique, total number of balloon inflations and total number of balloon exchanges with respect to the absolute change in mean aortic valve gradient occurring during the valvuloplasty procedure. In addition, there was a significant correlation between the maximal time of valvuloplasty balloon inflation with aortic valve area measured after valvuloplasty, and there were significant correlations of the total number of balloon inflations and total number of balloon exchanges with the aortic valve mean gradient measured after valvuloplasty. The overall complication rate for the procedure was 20.5%, including vascular injury in 11%, embolic phenomenon in 2.2%, ventricular perforation resulting in tamponade in 1.8%, massive aortic insufficiency in 1%, nonfatal arrhythmia in 0.8% and myocardial infarction in 0.2%.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
J. P. Dal-Bianco, B. K. Khandheria, F. Mookadam, F. Gentile, and P. P. Sengupta
Management of Asymptomatic Severe Aortic Stenosis
J. Am. Coll. Cardiol., October 14, 2008; 52(16): 1279 - 1292.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
P. T.L. Chiam and C. E. Ruiz
Percutaneous Transcatheter Aortic Valve Implantation: Assessing Results, Judging Outcomes, and Planning Trials: The Interventionalist Perspective
J. Am. Coll. Cardiol. Intv., August 1, 2008; 1(4): 341 - 350.
[Abstract] [Full Text] [PDF]


Home page
Arch NeurolHome page
P. Khatri and S. E. Kasner
Ischemic strokes after cardiac catheterization: opportune thrombolysis candidates?
Arch Neurol, June 1, 2006; 63(6): 817 - 821.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. A. Vassiliades Jr, P. C. Block, L. H. Cohn, D. H. Adams, J. S. Borer, T. Feldman, D. R. Holmes, W. K. Laskey, B. W. Lytle, M. J. Mack, et al.
The Clinical Development of Percutaneous Heart Valve Technology: A Position Statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA)
J. Am. Coll. Cardiol., May 3, 2005; 45(9): 1554 - 1560.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
American College of Cardiology Foundation (ACCF) a, T. A. Vassiliades Jr, P. C. Block, L. H. Cohn, D. H. Adams, J. S. Borer, T. Feldman, D. R. Holmes, W. K. Laskey, B. W. Lytle, et al.
The clinical development of percutaneous heart valve technology: A position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI)
J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 970 - 976.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. A. Vassiliades Jr, P. C. Block, L. H. Cohn, D. H. Adams, J. S. Borer, T. Feldman, D. R. Holmes, W. K. Laskey, B. W. Lytle, M. J. Mack, et al.
The Clinical Development of Percutaneous Heart Valve Technology: A Position Statement of The Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI)
Ann. Thorac. Surg., May 1, 2005; 79(5): 1812 - 1818.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
T.-M. Lee, S.-F. Su, M.-F. Chen, C.-S. Liau, and Y.-T. Lee
Percutaneous Transvenous Mitral Balloon Valvuloplasty Alone in Patients with Combined Aortic and Mitral Stenosis
Angiology, May 1, 1997; 48(5): 445 - 450.
[Abstract] [PDF]


Home page
NEJMHome page
J. B. Wong, D. N. Salem, and S. G. Pauker
You're Never Too Old
N. Engl. J. Med., April 1, 1993; 328(13): 971 - 975.
[Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1991 by the American College of Cardiology Foundation.