Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 17:94-99
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sanborn, T.
Right arrow Articles by Ambrose, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sanborn, T.
Right arrow Articles by Ambrose, J.

Percutaneous coronary excimer laser-assisted balloon angioplasty: initial clinical and quantitative angiographic results in 50 patients

TA Sanborn, Torre SR, SK Sharma, RA Hershman, M Cohen, W Sherman, and JA Ambrose

Department of Medicine, Mount Sinai Medical Center, New York, New York 10029.

The initial clinical experience and quantitative angiographic results of percutaneous coronary excimer laser-assisted balloon angioplasty are described for 55 lesions in 50 patients. With use of a xenon chloride (308 nm) excimer laser generator and 1.5 to 1.75 mm catheters, excimer laser angioplasty was attempted at 135 ns pulse width, 25 to 40 Hz repetition rate, 2 to 5 s laser delivery time and 30 to 60 mJ/mm2 energy fluence. Laser success (greater than 20% reduction in absolute percent diameter stenosis) was achieved in 41 (75%) of 55 lesions, with 100% subsequent balloon angioplasty success (less than 50% residual stenosis). By quantitative digital caliper technique, the percent diameter stenosis (mean +/- SE) was reduced from 81 +/- 1% to 50 +/- 3% after excimer laser angioplasty (p less than 0.001) and to 20 +/- 1% after balloon angioplasty (p less than 0.001); minimal luminal diameter increased from 0.56 +/- 0.04 to 1.46 +/- 0.08 mm (p less than 0.001) and 2.03 +/- 0.07 mm (p less than 0.001), respectively. By videodensitometric techniques, the percent area stenosis decreased from 86 +/- 2% to 54 +/- 3% after excimer angioplasty (p less than 0.001) and to 26 +/- 3% after balloon angioplasty (p less than 0.001). There were no perforations, need for emergency bypass surgery or deaths. The overall incidence of abrupt closure (3.6%), dissection (1.8%), embolization (1.8%), filling defect (6%), myocardial infarction (5.5%), side branch occlusion (3.6%) or spasm (3.6%) was infrequent and more related to subsequent balloon angioplasty than to the laser procedure.(ABSTRACT TRUNCATED AT 250 WORDS)




 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement