Detection of coronary blood flow associated with left main coronary artery stenosis by transesophageal Doppler color flow echocardiography
M Yamagishi,
T Yasu,
K Ohara,
M Kuro,
and
K Miyatake
Cardiology Division of Medicine, National Cardiovascular Center, Osaka, Japan.
Demonstration of disordered blood flow in a coronary artery may be helpful in anticipating the presence of stenosis. To examine the possibility of disordered coronary blood flow associated with left main coronary stenosis, left main coronary flow was visualized by transesophageal Doppler color flow echocardiography in 52 patients undergoing coronary angiography. Twenty patients had significant left main coronary stenosis (Group 1) and 32 patients did not (Group 2). Adequate two-dimensional echocardiographic images of the left main coronary artery were obtained in 17 patients in Group 1 and 30 patients in Group 2. Sixteen patients in Group 1, including five patients in whom the stenosis could not clearly be defined by two-dimensional echocardiography, exhibited the aliased reddish-yellowish elements producing the mosaic pattern at the stenotic or poststenotic segments, or both. In contrast, nonaliased bluish jets, suggesting laminar flow away from the transducer, were seen in echocardiograms from 27 patients in Group 2. This group included four patients with stenosis-like images on two-dimensional echocardiography. The aliased mosaic pattern was found in only three patients in Group 2 (p less than 0.01). Thus, sensitivity to detect the stenosis was improved when Doppler color flow imaging was applied. Flow velocity was significantly higher at the site of stenosis in patients in Group 1 (116 +/- 28 cm/s, n = 10, mean +/- SD) than in Group 2 (29 +/- 12 cm/s, n = 21, p less than 0.01), suggesting that the augmentation of flow velocity with or without turbulence due to the stenosis contributed to the appearance of the mosaic flow images.(ABSTRACT TRUNCATED AT 250 WORDS)
This article has been cited by other articles:

|
 |

|
 |
 
C. von Birgelen and P. M.J. Verhorst
Novel ultrasonic insight into coronary arteries
Eur Heart J Cardiovasc Imaging,
November 1, 2008;
9(6):
713 - 714.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. Sharoni, E. Erez, Y. Shapira, B. A. Vidne, and A. Sagie
Transesophageal echocardiography evaluation and follow-up of left main coronary artery patch angioplasty
Eur J Cardiothorac Surg,
April 1, 2003;
23(4):
585 - 588.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Hozumi, K. Yoshida, T. Akasaka, Y. Asami, Y. Kanzaki, Y. Ueda, A. Yamamuro, T. Takagi, and J. Yoshikawa
Value of acceleration flow and the prestenotic to stenotic coronary flow velocity ratio by transthoracic color doppler echocardiography in noninvasive diagnosis of restenosis after percutaneous transluminal coronary angioplasty
J. Am. Coll. Cardiol.,
January 1, 2000;
35(1):
164 - 168.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Isaaz, A. da Costa, J. P. de Pasquale, A. Cerisier, and M. Lamaud
Use of the continuity equation for transesophageal Doppler assessment of severity of proximal left coronary artery stenosis: a quantitative coronary angiography validation study
J. Am. Coll. Cardiol.,
July 1, 1998;
32(1):
42 - 48.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. F. Redberg, Y. Sobol, T. M. Chou, M. Malloy, S. Kumar, E. Botvinick, and J. Kane
Adenosine-Induced Coronary Vasodilatation During Transesophageal Doppler Echocardiography : Rapid and Safe Measurement of Coronary Flow Reserve Ratio Can Predict Significant Left Anterior Descending Coronary Stenosis
Circulation,
July 15, 1995;
92(2):
190 - 196.
[Abstract]
[Full Text]
|
 |
|
|