Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 17:143-151
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kadish, A.
Right arrow Articles by Morady, F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kadish, A.
Right arrow Articles by Morady, F

Differences in QRS configuration during unipolar pacing from adjacent sites: implications for the spatial resolution of pace-mapping

AH Kadish, K Childs, S Schmaltz, and F Morady

Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor.

To examine the spatial resolution of unipolar pace-mapping, 12 lead electrocardiograms (ECGs) recorded during pacing from each of the poles of a quadripolar catheter (5 mm interelectrode distance) were examined. Unipolar pacing was performed from each of the poles at late diastolic threshold, twice threshold and 10 mA at a cycle length of 500 ms. In 15 patients, pacing was performed at the right ventricular apex and in 14 at various left ventricular sites. Pacing from the distal catheter pole at threshold (index ECG) was used to simulate the site of origin of ventricular tachycardia, and all other ECGs were compared with the index ECG. Electrocardiograms were evaluated by two independent observers for 1) minor configuration differences (notch, new small component, change in the amplitude of individual components or change in QRS shape); 2) major differences in configuration (new large component, marked change in the amplitude of an existing component or two minor changes); and 3) peak to peak changes in amplitude. Minor differences in configuration were seen in a mean 2.4 +/- 1.9, 4.6 +/- 2.4 and 4.4 +/- 2.9 leads during pacing at 5, 10 and 15 mm from the distal electrode (index site). Major differences in configuration were seen in a mean of 0.3 +/- 0.5, 2.1 +/- 2.1 and 3.7 +/- 2.3 leads during pacing at 5, 10 and 15 mm from the index site. Differences in amplitude were seen in a mean of 3.1 +/- 2.2, 5.6 +/- 2.5 and 6.8 +/- 3.0 leads per ECG during pacing at 5, 10 and 15 mm from the index ECG pacing site, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Eur Heart JHome page
T. Datino, J. Almendral, E. Gonzalez-Torrecilla, F. Atienza, F. J. Garcia-Fernandez, A. Arenal, L. Atea, and F. Fernandez-Aviles
Rate-related changes in QRS morphology in patients with fixed bundle branch block: implications for differential diagnosis of wide QRS complex tachycardia
Eur. Heart J., October 1, 2008; 29(19): 2351 - 2358.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. U. Klemm, R. Ventura, D. Steven, C. Johnsen, T. Rostock, B. Lutomsky, T. Risius, T. Meinertz, and S. Willems
Catheter Ablation of Multiple Ventricular Tachycardias After Myocardial Infarction Guided by Combined Contact and Noncontact Mapping
Circulation, May 29, 2007; 115(21): 2697 - 2704.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. B. Brunckhorst, E. Delacretaz, K. Soejima, W. H. Maisel, P. L. Friedman, and W. G. Stevenson
Identification of the Ventricular Tachycardia Isthmus After Infarction by Pace Mapping
Circulation, August 10, 2004; 110(6): 652 - 659.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. P. Gerstenfeld, S. Dixit, D. J. Callans, Y. Rajawat, R. Rho, and F. E. Marchlinski
Quantitative comparison of spontaneous and paced 12-lead electrocardiogram during right ventricular outflow tract ventricular tachycardia
J. Am. Coll. Cardiol., June 4, 2003; 41(11): 2046 - 2053.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Furniss, R Anil-Kumar, J P Bourke, R Behulova, and E Simeonidou
Radiofrequency ablation of haemodynamically unstable ventricular tachycardia after myocardial infarction
Heart, December 1, 2000; 84(6): 648 - 652.
[Abstract] [Full Text]


Home page
CirculationHome page
R. Goyal, M. Harvey, E. G. Daoud, K. Brinkman, B. P. Knight, M. Bahu, R. Weiss, F. Bogun, K. C. Man, S. A. Strickberger, et al.
Effect of Coupling Interval and Pacing Cycle Length on Morphology of Paced Ventricular Complexes: Implications for Pace Mapping
Circulation, December 1, 1996; 94(11): 2843 - 2849.
[Abstract] [Full Text]


Home page
CirculationHome page
K. C. Man, K.K. Chan, P. Kovack, R. Goyal, F. Bogun, M. Harvey, E. Daoud, S. A. Strickberger, and F. Morady
Spatial Resolution of Atrial Pace Mapping as Determined by Unipolar Atrial Pacing at Adjacent Sites
Circulation, September 15, 1996; 94(6): 1357 - 1363.
[Abstract] [Full Text]


Home page
PerfusionHome page
G. Wright, L. Michalis, and P. Rolfe
Insularity and professional protectionism or matrixing and professional security in the provision of perfusion services
Perfusion, March 1, 1995; 10(2): 89 - 92.
[PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement