Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 17:133-138
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rosenbaum, M.
Right arrow Articles by Garan, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rosenbaum, M.
Right arrow Articles by Garan, H

Immediate reproducibility of electrically induced sustained monomorphic ventricular tachycardia before and during antiarrhythmic therapy

MS Rosenbaum, DJ Wilber, D Finkelstein, JN Ruskin, and H Garan

Cardiac Unit, Massachusetts General Hospital, Harvard Medical School, Boston 02114.

The immediate reproducibility of sustained ventricular tachycardia induction was evaluated prospectively during 106 studies performed in 53 patients with clinical sustained monomorphic ventricular tachycardia. Programmed electrical stimulation was performed twice, using the same protocol during 53 drug-free studies and 53 subsequent studies on antiarrhythmic therapy. Sustained monomorphic ventricular tachycardia was reproduced in 104 (98%) of the 106 studies. There was no significant difference in the incidence of reproducible tachycardia in the drug-free state compared with that observed during treatment with different classes of antiarrhythmic drugs. An increase in the number of extrastimuli was required to reinitiate the tachycardia in 9 (11%) of 83 studies in which single or double extrastimuli were initially required to induce the tachycardia. In 39 (37%) of 104 studies with reproducible tachycardia induction, the two tachycardias significantly differed in electrocardiographic (ECG) configuration and cycle length. These observations suggest that the overall reproducibility of ventricular tachycardia induction is sufficiently high to provide a reliable marker for evaluating the efficacy of therapeutic interventions. However, specific tachycardia characteristics such as cycle length and ECG configuration are more variable even within the same study and may be less useful in assessing the effects of subsequent interventions.


This article has been cited by other articles:


Home page
CirculationHome page
D. Mehta, J. Curwin, J. A. Gomes, and V. Fuster
Sudden Death in Coronary Artery Disease : Acute Ischemia Versus Myocardial Substrate
Circulation, November 4, 1997; 96(9): 3215 - 3223.
[Full Text]


Home page
CirculationHome page
A. M. Gillis, R. S. Sheldon, D. G. Wyse, J. W. Leitch, R. Yee, G. J. Klein, H. J. Duff, and L. B. Mitchell
Long-term Reproducibility of Ventricular Tachycardia Induction in Patients With Implantable Cardioverter/Defibrillators : Serial Noninvasive Studies
Circulation, May 15, 1995; 91(10): 2605 - 2613.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement