JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1990; 16:1398-1407
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Segal, J
Right arrow Articles by Schuenemeyer, T.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Segal, J
Right arrow Articles by Schuenemeyer, T.

Instantaneous and continuous cardiac output in humans obtained with a Doppler pulmonary artery catheter

J Segal, M Nassi, AJ Ford Jr, and TD Schuenemeyer

University of California, School of Medicine, San Francisco.

A new Doppler pulmonary artery catheter was used to measure instantaneous and continuous cardiac output in both an in vitro model and in 44 patients undergoing cardiac catheterization. Cardiac output was calculated with use of the Doppler catheter-determined instantaneous space-average velocity and the ultrasonically determined instantaneous vessel area. Doppler flow and thermodilution were compared with electromagnetic flow in the in vitro model and with Fick cardiac output in patients. Doppler catheter-determined flow was highly predictive of electro-magnetic flow in the pulsatile flow model (r = 0.99, slope [m] = 1.01 and SEE = 0.05) and appeared comparable to thermodilution measurements (r = 1.00, m = 1.03 and SEE = 0.02). In patients undergoing cardiac catheterization, Doppler catheter-determined cardiac output appeared to modestly underestimate Fick cardiac output (r = 0.82, m = 0.80 and SEE = 0.09; mean error +/- SEM = -0.26 +/- 0.14 liters/min). However, predictive accuracy was comparable to simultaneously obtained thermodilution measurements (r = 0.85, m = 1.07 and SEE = 0.10; mean error +/- SEM = 0.61 +/- 0.16 liters/min). This new Doppler catheter system utilizes multiple ultrasound transducers to provide angle-independent measurements of vessel diameter and instantaneous velocity within the main pulmonary artery, resulting in a more accurate assessment of Doppler-derived cardiac output. In addition, useful information concerning hemodynamic variables such as peak flow, acceleration, deceleration, stroke work and pulmonary impedance may be derived.


This article has been cited by other articles:


Home page
Cardiovasc ResHome page
E. Sloth, M. Kruse, K. C Houlind, E. M Pedersen, and J.M. Hasenkam
The impact of ischemic heart disease on main pulmonary artery blood flow patterns: a comparison between magnetic resonance phase velocity mapping and transesophageal color Doppler
Cardiovasc Res, December 1, 1997; 36(3): 377 - 385.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
E. Sloth, K. C. Houlind, E. M. Pedersen, and J.M. Hasenkam
Where to place the Doppler sample volume in the human main pulmonary artery: evaluated from magnetic resonance phase velocity maps
Cardiovasc Res, January 1, 1997; 33(1): 156 - 163.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1990 by the American College of Cardiology Foundation.