J Am Coll Cardiol, 1990; 16:1310-1314
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Almagor, Y
Right arrow Articles by Leon, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Almagor, Y
Right arrow Articles by Leon, M.

Balloon expandable stent implantation in stenotic right heart valved conduits

Y Almagor, LG Prevosti, AL Bartorelli, G Keren, VJ Ferrans, M Jones, and MB Leon

Cardiology Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892.

Although valved conduits have been used successfully in severe forms of right ventricular-pulmonary artery discontinuity, progressive valved conduit stenosis is an important clinical problem. To determine the feasibility of reducing right heart valved conduit stenosis with a balloon expandable stent, a baboon model was used, in which the pulmonary artery was ligated and a right ventricular to pulmonary artery 14 mm bioprosthetic Dacron valved conduit implanted. In five baboons, at an average of 40 months after valved conduit implantation, fibrointimal stenosis at the valve site resulted in narrowing and a mean transconduit pressure gradient of 49 mm Hg (range 33 to 65). A tubular slotted steel stent (1.2 cm long) was deployed within the valved conduit after inflation of an 8 to 15 mm diameter balloon catheter that was introduced through the femoral vein. A stent was delivered to all valved conduits; however, in two baboons, balloon undersizing resulted in stent dislodgment. In the remaining three baboons, the transconduit gradient was reduced by 59% (49 to 20 mm Hg) and right ventricular systolic pressure decreased acutely by 35% (77 to 50 mm Hg). It is concluded that stent deployment is feasible in right ventricular to pulmonary artery stenotic valved conduits and may result in significant hemodynamic improvement. However, successful stent delivery is critically dependent on the proper selection of stent length and balloon diameter.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
S. Aggarwal, S. Garekar, T. J. Forbes, and D. R. Turner
Is Stent Placement Effective for Palliation of Right Ventricle to Pulmonary Artery Conduit Stenosis?
J. Am. Coll. Cardiol., January 30, 2007; 49(4): 480 - 484.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. F. Peng, D. B. McElhinney, A. W. Nugent, A. J. Powell, A. C. Marshall, E. A. Bacha, and J. E. Lock
Endovascular Stenting of Obstructed Right Ventricle-to-Pulmonary Artery Conduits: A 15-Year Experience
Circulation, June 6, 2006; 113(22): 2598 - 2605.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
H Sugiyama, W Williams, and L N Benson
Implantation of endovascular stents for the obstructive right ventricular outflow tract
Heart, August 1, 2005; 91(8): 1058 - 1063.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. A. C. Pedra, H. Justino, D. G. Nykanen, G. V. MD, J. G. Coles, W. G. Williams, R. M. Freedom, and L. N. Benson
Percutaneous stent implantation to stenotic bioprosthetic valves in the pulmonary position
J. Thorac. Cardiovasc. Surg., July 1, 2002; 124(1): 82 - 87.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Ovaert, C. A. Caldarone, B. W. McCrindle, D. Nykanen, R. M. Freedom, J. G. Coles, W. G. Williams, and L. N. Benson
ENDOVASCULAR STENT IMPLANTATION FOR THE MANAGEMENT OF POSTOPERATIVE RIGHT VENTRICULAR OUTFLOW TRACT OBSTRUCTION: CLINICAL EFFICACY
J. Thorac. Cardiovasc. Surg., November 1, 1999; 118(5): 886 - 893.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Nemoto, A. Sakai, Y. Miyoshi, K. Yasuhara, and M. Seguchi
Pathologic finding of restenosis in stent-implanted right ventricle-pulmonary artery extracardiac conduit
Ann. Thorac. Surg., October 1, 1999; 68(4): 1411 - 1413.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1990 by the American College of Cardiology Foundation.