JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1990; 16:1143-1153
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lambertz, H
Right arrow Articles by Hanrath, P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lambertz, H
Right arrow Articles by Hanrath, P

Simultaneous transesophageal atrial pacing and transesophageal two-dimensional echocardiography: a new method of stress echocardiography

H Lambertz, A Kreis, H Trumper, and P Hanrath

Medical Clinic I, Klinikum Rheinisch-Westfalische Technische Hochschule, Aachen, Federal Republic of Germany.

The diagnostic use of exercise echocardiography has been widely reported. However, transthoracic exercise echocardiography is inadequate in up to 20% of patients because of poor image quality related to exercise. In an attempt to overcome these limitations, a system was developed in which transesophageal echocardiography is combined with simultaneous transesophageal atrial pacing by means of the same probe. In a prospective study, transesophageal echocardiography was performed before, during and immediately after maximal atrial pacing in 50 patients with suspected coronary artery disease. Results of transesophageal stress echocardiography were considered abnormal when new pacing-induced regional wall motion abnormalities were observed. Correlative routine bicycle exercise testing was carried out in 44 patients. Cardiac catheterization was performed in all patients. The success rate in obtaining high quality diagnostic images was 100% by transesophageal echocardiography. All nine patients without angiographic evidence of coronary artery disease had a normal result on the transesophageal stress echocardiogram (100% specificity). Thirty-eight of 41 patients with coronary artery disease (defined as greater than or equal to 50% luminal diameter narrowing of at least one major vessel) had an abnormal result on the transesophageal stress echocardiogram (93% sensitivity). The sensitivity of the technique for one, two or three vessel disease was 85%, 100% and 100%, respectively, compared with 44%, 50% and 83%, respectively, for bicycle exercise testing; the 12 lead electrocardiogram (ECG) during rapid atrial pacing showed a sensitivity of 25%, 64% and 86%, respectively. Thus, rapid atrial pacing combined with simultaneous transesophageal echocardiography is a highly specific and sensitive technique for the detection of coronary artery disease. Ischemia-induced wall motion abnormalities were detected earlier than observed ECG changes. The technique appears to be particularly suited to patients who are unable to perform an active stress test or those with poor quality transthoracic echocardiograms.


This article has been cited by other articles:


Home page
HeartHome page
E De Caro, G P Ussia, M Marasini, and G Pongiglione
Transoesophageal atrial pacing combined with transthoracic two dimensional echocardiography: experience in patients operated on with arterial switch operation for transposition of the great arteries
Heart, January 1, 2003; 89(1): 91 - 95.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
P. Hanrath
IMAGING TECHNIQUES: Transoesophageal Echo-Doppler in cardiology
Heart, November 1, 2001; 86(5): 586 - 592.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Atar, T. Nagai, B. Cercek, T. Z. Naqvi, H. Luo, and R. J. Siegel
Pacing stress echocardiography: an alternative to pharmacologic stress testing
J. Am. Coll. Cardiol., November 15, 2000; 36(6): 1935 - 1941.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A Franke, R Hoffmann, H P Kühl, W Lepper, O A Breithardt, M Schormann, and P Hanrath
Non-contrast second harmonic imaging improves interobserver agreement and accuracy of dobutamine stress echocardiography in patients with impaired image quality
Heart, February 1, 2000; 83(2): 133 - 140.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
C.-Y. Lee, P. A. Pellikka, R. B. McCully, D. W. Mahoney, and J. B. Seward
Nonexercise stress transthoracic echocardiography: transesophageal atrial pacing versus dobutamine stress
J. Am. Coll. Cardiol., February 1, 1999; 33(2): 506 - 511.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. A. Panza, R. V. Curiel, J. M. Laurienzo, A. A. Quyyumi, and V. Dilsizian
Relation Between Ischemic Threshold Measured During Dobutamine Stress Echocardiography and Known Indices of Poor Prognosis in Patients With Coronary Artery Disease
Circulation, October 15, 1995; 92(8): 2095 - 2101.
[Abstract] [Full Text]


Home page
CirculationHome page
J. A. Panza, V. Dilsizian, J. M. Laurienzo, R. V. Curiel, and P. T. Katsiyiannis
Relation Between Thallium Uptake and Contractile Response to Dobutamine : Implications Regarding Myocardial Viability in Patients With Chronic Coronary Artery Disease and Left Ventricular Dysfunction
Circulation, February 15, 1995; 91(4): 990 - 998.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1990 by the American College of Cardiology Foundation.