JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1990; 16:569-575
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hjemdahl-Monsen, C.
Right arrow Articles by Fuster, V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hjemdahl-Monsen, C.
Right arrow Articles by Fuster, V

Angiographic patterns of balloon inflation during percutaneous transluminal coronary angioplasty: role of pressure-diameter curves in studying distensibility and elasticity of the stenotic lesion and the mechanism of dilation

CE Hjemdahl-Monsen, JA Ambrose, S Borrico, M Cohen, W Sherman, D Alexopoulos, R Gorlin, and V Fuster

Department of Medicine, Mount Sinai Medical Center, New York, New York.

There are few in vivo data concerning the mechanisms of balloon inflation during coronary angioplasty. To characterize how lesions dilate, videodensitometry was used to measure the diameter of the inflated balloon across 29 coronary lesions in 27 patients. Pressure-diameter curves for each lesion were derived with use of a standardized incremental inflation protocol in which pressures between 2 and 6 atm in 3 mm low profile balloons approximated normal vessel diameter. The diameter of coronary stenosis before and after angioplasty was also measured. Pressure-diameter curves showed that the most improvement in luminal caliber occurred at low inflation pressure. A distensibility factor was defined as the ratio of the amount of balloon inflation at 2 atm compared with the balloon diameter at 6 atm. Eccentric irregular lesions (n = 11) had a greater distensibility factor (0.49 +/- 0.17) than did lesions (n = 18) without this configuration (0.33 +/- 0.14) (p less than 0.02). The former were soft, presumably because of thrombus in these lesions. In addition, there were no differences in patterns of balloon inflation for lesions requiring additional inflation or for dilations resulting in an intimal crack or dissection after angioplasty. There was often a loss of luminal caliber when balloon diameter at 6 atm was compared with the diameter after angioplasty. This was defined as elasticity or recoil. There was a significant direct correlation between the amount of elasticity and the extent of balloon inflation at 6 atm (that is, lesions more fully dilated at 6 atm showed more elasticity).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
A. Rodriguez, F. Ayala, V. Bernardi, O. Santaera, E. Marchand, C. Pardinas, C. Mauvecin, D. Vogel, L. C. Harrell, I. F. Palacios, et al.
Optimal coronary balloon angioplasty with provisional stenting versus primary stent (OCBAS): Immediate and long-term follow-up results
J. Am. Coll. Cardiol., November 1, 1998; 32(5): 1351 - 1357.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Bermejo, J. Botas, E. Garcia, J. Elizaga, J. Osende, J. Soriano, M. Abeytua, and J. L. Delcan
Mechanisms of Residual Lumen Stenosis After High-Pressure Stent Implantation : A Quantitative Coronary Angiography and Intravascular Ultrasound Study
Circulation, July 14, 1998; 98(2): 112 - 118.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A Murray, V Allen, and M K Bennett
Validation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: laboratory assessment with necropsy segments
Heart, June 1, 1998; 79(6): 608 - 612.
[Abstract] [Full Text]


Home page
CirculationHome page
M. J. Vonesh, L. F. Mockros, C. J. Davidson, K. B. Chandran, and D. D. McPherson
In Vitro Identification of Angioplasty-Induced Injury by Use of Vascular Acoustic Emissions
Circulation, February 18, 1997; 95(4): 1022 - 1029.
[Abstract] [Full Text]


Home page
CirculationHome page
G. S. Mintz, J. J. Popma, A. D. Pichard, K. M. Kent, L. F. Satler, S. Chiu Wong, M. K. Hong, J. A. Kovach, and M. B. Leon
Arterial Remodeling After Coronary Angioplasty : A Serial Intravascular Ultrasound Study
Circulation, July 1, 1996; 94(1): 35 - 43.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1990 by the American College of Cardiology Foundation.