Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1990; 16:502-506
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sanborn, T.
Right arrow Articles by Fuster, V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sanborn, T.
Right arrow Articles by Fuster, V

Coronary excimer laser angioplasty: reduced complications and indium-111 platelet accumulation compared with thermal laser angioplasty

TA Sanborn, D Alexopoulos, JD Marmur, H Kahn, JJ Badimon, L Badimon, and V Fuster

Department of Medicine, Mount Sinai Medical Center, New York, New York 10029.

The relative safety and thrombogenicity of pulsed excimer and thermal laser angioplasty systems were compared in 20 normal coronary artery segments in a total of seven pigs. Using similar over the wire catheter systems and laser delivery periods of 3 to 5 s, thermal laser angioplasty was achieved with a 1.3 mm metal probe heated with 10 W of continuous argon laser energy and excimer laser angioplasty was performed with a 4.5F excimer laser catheter consisting of 13 concentrically arranged 200 microns fiber optics delivering 35 to 40 mJ/mm2 of xenon chloride (308 nm) excimer laser irradiation at a repetition rate of 25 to 30 Hz and a pulse duration of 120 ns. On angiography, the incidence of vessel perforation (1 in 10 versus 3 in 10) and abrupt vessel closure (0 in 10 versus 2 in 10) was less with excimer compared with thermal laser angioplasty. Macroscopically, there was a greater incidence of mural and occlusive thrombus formation after thermal laser than after pulsed excimer laser angioplasty. Histologic examination confirmed that this thrombogenicity was associated with greater charring and coagulation necrosis of the media. Quantitative indium-111-labeled platelet deposition was significantly increased after thermal laser angioplasty (median 87.2 x 10(6)/cm length) compared with excimer-treated (0.4 x 10(6)/cm length) or control (1.2 x 10(6)cm length) segments (p less than 0.001). Thus, excimer laser angioplasty was found to result in fewer complications and, as a consequence, less thrombosis and platelet accumulation than did thermal laser angioplasty.




 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement