Aortic regurgitation shortens Doppler pressure half-time in mitral stenosis: clinical evidence, in vitro simulation and theoretic analysis
FA Flachskampf,
AE Weyman,
L Gillam,
CM Liu,
VM Abascal,
and
JD Thomas
Noninvasive Cardiac Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston 02114.
Mitral valve areas determined by Doppler pressure half-time were compared with areas obtained by planimetry in two groups of patients with mitral stenosis: 24 patients without aortic regurgitation and 32 patients with more than grade 1 aortic regurgitation. The severity of aortic regurgitation was assessed by color flow mapping; 17 patients had grade 2, 10 had grade 3 and 5 had grade 4 aortic regurgitation. Regression equations for pressure half-time area versus planimetry mitral valve area were calculated separately for the aortic regurgitation (r = 0.88) and the nonaortic regurgitation group (r = 0.86); analysis of covariance revealed a significant (p less than 0.001) difference between the two groups leading to overestimation of planimetry area by the pressure half-time method in the aortic regurgitation group. The mitral valve areas in the group without regurgitation were best calculated with the expression 239/T1/2 (r = 0.77) as compared with a best fit of 195/T1/2 (r = 0.85) for the aortic regurgitation group. To elucidate the mechanisms affecting pressure half-time in aortic regurgitation, an in vitro model of mitral inflow in the presence of varying regurgitant volumes and different ventricular chamber compliances was used. Aortic regurgitation shortened directly measured pressure half-time proportional to the regurgitant fraction but an increase in left ventricular compliance could offset this effect. Finally, in a mathematic model of mitral inflow the competing effects of aortic regurgitation and chamber compliance could be confirmed. In conclusion, aortic regurgitation results clinically in a significant net shortening of pressure half-time leading to mitral valve area overestimation. However, the effect is moderate and individually unpredictable because of changes in chamber compliance.
This article has been cited by other articles:

|
 |

|
 |
 
J. Dreyfus, E. Brochet, L. Lepage, D. Attias, C. Cueff, D. Detaint, D. Himbert, B. Iung, A. Vahanian, and D. Messika-Zeitoun
Real-time 3D transoesophageal measurement of the mitral valve area in patients with mitral stenosis
Eur Heart J Cardiovasc Imaging,
October 1, 2011;
12(10):
750 - 755.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Lembcke, T. Durmus, Y. Westermann, A. Geigenmueller, B. Claus, C. Butler, and H. Thiele
Assessment of Mitral Valve Stenosis by Helical MDCT: Comparison With Transthoracic Doppler Echocardiography and Cardiac Catheterization
Am. J. Roentgenol.,
September 1, 2011;
197(3):
614 - 622.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. M. Salem Omar, H. Tanaka, T. K. AbdelDayem, A. S. Sadek, H. Raslaan, A. Al-Sherbiny, K. Yamawaki, K. Ryo, Y. Fukuda, K. Norisada, et al.
Comparison of mitral valve area by pressure half-time and proximal isovelocity surface area method in patients with mitral stenosis: effect of net atrioventricular compliance
Eur Heart J Cardiovasc Imaging,
April 1, 2011;
12(4):
283 - 290.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Evangelista, F. Flachskampf, P. Lancellotti, L. Badano, R. Aguilar, M. Monaghan, J. Zamorano, P. Nihoyannopoulos, and on behalf of the European Association of Echocardi
European Association of Echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies
Eur Heart J Cardiovasc Imaging,
July 1, 2008;
9(4):
438 - 448.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Zamorano, L. Perez de Isla, L. Sugeng, P. Cordeiro, J. L. Rodrigo, C. Almeria, L. Weinert, T. Feldman, C. Macaya, R. M. Lang, et al.
Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: role of real-time 3D echocardiography
Eur. Heart J.,
December 1, 2004;
25(23):
2086 - 2091.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Zamorano, P. Cordeiro, L. Sugeng, L. Perez de Isla, L. Weinert, C. Macaya, E. Rodriguez, and R. M. Lang
Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: An accurate and novel approach
J. Am. Coll. Cardiol.,
June 2, 2004;
43(11):
2091 - 2096.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Messika-Zeitoun, S. Fung Yiu, B. Cormier, B. Iung, C. Scott, A. Vahanian, A Jamil Tajik, and M. Enriquez-Sarano
Sequential assessment of mitral valve area during diastole using colour M-mode flow convergence analysis: new insights into mitral stenosis physiology
Eur. Heart J.,
July 1, 2003;
24(13):
1244 - 1253.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. M. Binder, R. Rosenhek, G. Porenta, G. Maurer, and H. Baumgartner
Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography
J. Am. Coll. Cardiol.,
October 1, 2000;
36(4):
1355 - 1361.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|