JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1990; 16:332-339
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levine, M.
Right arrow Articles by Baim, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levine, M.
Right arrow Articles by Baim, D.

Clinical and angiographic results of balloon-expandable intracoronary stents in right coronary artery stenoses

MJ Levine, BM Leonard, JA Burke, ID Nash, RD Safian, DJ Diver, and DS Baim

Charles A Dana Research Institute, Boston, Massachusetts.

Balloon-expandable stents were placed successfully in 35 (95%) of 37 patients whose right coronary artery lesion was believed to have a poor short- or long-term prognosis with conventional balloon angioplasty because of prior restenosis or adverse lesion morphology. Quantitative angiography showed a reduction in stenosis diameter from 83 +/- 14% to 42 +/- 14% after conventional balloon dilation, with a further reduction to -3 +/- 12% after stent placement (p less than 0.001). There were no acute stent thromboses, but one patient (with two stents and unstented distal disease) developed subacute thrombosis on day 8 after self-discontinuation of warfarin and was treated with thrombolytic therapy and redilation. Follow-up angiography was performed at 4 to 6 months in 25 patients, demonstrating restenosis (83 +/- 13%) in 4 (57%) of 7 patients with multiple stents, but only 3 (17%) of 18 patients with a single stent (p less than 0.05). Six of the seven in-stent restenotic lesions were subtotal (80 +/- 12%) and were subjected to repeat conventional balloon angioplasty (postdilation stenosis 13 +/- 21%). The 18 patients without restenosis had a maximal in-stent diameter stenosis of 29 +/- 15%, corresponding to a maximal focal neointimal thickness of 0.68 +/- 0.26 mm within the stented segment. These preliminary results suggest that the Schatz-Palmaz stent may be a useful adjunctive device in the performance of coronary angioplasty.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
Y. Kobayashi, J. De Gregorio, N. Kobayashi, T. Akiyama, B. Reimers, L. Finci, C. Di Mario, and A. Colombo
Stented segment length as an independent predictor of restenosis
J. Am. Coll. Cardiol., September 1, 1999; 34(3): 651 - 659.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Rogers and E. R. Edelman
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Circulation, June 15, 1995; 91(12): 2995 - 3001.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1990 by the American College of Cardiology Foundation.