JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1990; 16:316-324
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feinstein, S.
Right arrow Articles by Shah, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feinstein, S.
Right arrow Articles by Shah, P.

Safety and efficacy of a new transpulmonary ultrasound contrast agent: initial multicenter clinical results

SB Feinstein, J Cheirif, FJ Ten Cate, PR Silverman, PA Heidenreich, C Dick, RM Desir, WF Armstrong, MA Quinones, and PM Shah

Department of Medicine, University of Chicago, Illinois.

Myocardial contrast echocardiography has been found to be a safe and useful technique for evaluating relative changes in myocardial perfusion and delineating areas at risk. Although earlier contrast agents required direct delivery into the coronary arteries or aortic root, a new echocardiographic contrast agent, sonicated albumin microspheres (Albunex), has been found to cross the pulmonary circulation in experimental models. To determine the safety and preliminary efficacy of intravenous injections of Albunex in humans, 71 patients at three independent medical institutions underwent two-dimensional echocardiographic examination before, during and after the administration of three intravenous doses of Albunex, ranging from 0.01 to 0.12 ml/kg body weight. All patients provided a complete history and underwent physical and neurologic examination and laboratory and electrocardiographic evaluation before the injections; all evaluations (except for the history) were repeated at 2 h and 3 days after the injections of Albunex. The efficacy of the injections was qualitatively assessed by two independent blinded observers using a grading system of 0 to +3, with 0 indicating an absence of contrast effect and +3 indicating full opacification of the cavities examined. All injections were well tolerated and no serious side effects were noted in any of the patients. Irrespective of dose group, a cavity opacification greater than or equal to +2 was seen in the right ventricle in 212 (88%) of 240 injections and in the left ventricle in 151 (63%) of 240 injections as judged by the independent observers. The degree of ventricular cavity opacification appeared to be dose and concentration related.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
M. L. Main, J. H. Goldman, and P. A. Grayburn
Thinking Outside the "Box" The Ultrasound Contrast Controversy
J. Am. Coll. Cardiol., December 18, 2007; 50(25): 2434 - 2437.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
R. Olszewski, J. Timperley, S. Cezary, M. Monaghan, P. Nihoyannopoulis, R. Senior, and H. Becher
The clinical applications of contrast echocardiography
Eur J Echocardiogr, June 1, 2007; 8(3): s13 - s23.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
K. Shigeta, K. Itoh, S. Ookawara, N. Taniguchi, and K. Omoto
The Effects of Levovist and DD-723 in Activating Platelets and Damaging Hepatic Cells of Rats
J. Ultrasound Med., July 1, 2005; 24(7): 967 - 974.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. S. Abramowicz
Ultrasonographic Contrast Media: Has the Time Come in Obstetrics and Gynecology?
J. Ultrasound Med., April 1, 2005; 24(4): 517 - 531.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. B. Feinstein
The powerful microbubble: from bench to bedside, from intravascular indicator to therapeutic delivery system, and beyond
Am J Physiol Heart Circ Physiol, August 1, 2004; 287(2): H450 - H457.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
B Cosyns, P El Haddad, H Lignian, C Daniels, C Weytjens, D Schoors, and G Van Camp
Contrast harmonic imaging improves the evaluation of left ventricular function in ventilated patients: comparison with transesophageal echocardiography
Eur J Echocardiogr, March 1, 2004; 5(2): 118 - 122.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
R. A. Meyer
History of Ultrasound in Cardiology
J. Ultrasound Med., January 1, 2004; 23(1): 1 - 11.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
K. Shigeta, K. Itoh, S. Ookawara, N. Taniguchi, and K. Omoto
Endothelial Cell Injury and Platelet Aggregation Induced by Contrast Ultrasonography in the Rat Hepatic Sinusoid
J. Ultrasound Med., January 1, 2004; 23(1): 29 - 36.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
A. Distante, R. Dankowski, P. Mincarone, C.G. Leo, E. Gianicolo, P. Voci, M.A. Morales, and D. Rovai
Contrast echocardiography and medical economics: looking into the crystal ball
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C39 - C47.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
P. Voci
The bubbles and the science of life
J. Am. Coll. Cardiol., August 1, 2000; 36(2): 625 - 627.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. P. Reilly, P. A. Tunick, R. J. Timmermans, B. Stein, B. P. Rosenzweig, and I. Kronzon
Contrast echocardiography clarifies uninterpretable wall motion in intensive care unit patients
J. Am. Coll. Cardiol., February 1, 2000; 35(2): 485 - 490.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
Y Myreng, P Molstad, K Ytre-Arne, M Aas, L Stoksflod, J O Nossen, and B Oftedal
Safety of the transpulmonary ultrasound contrast agent NC100100: a clinical and haemodynamic evaluation in patients with suspected or proved coronary artery disease
Heart, September 1, 1999; 82(3): 333 - 335.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. G. Hundley, A. M. Kizilbash, I. Afridi, F. Franco, R. M. Peshock, and P. A. Grayburn
Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging
J. Am. Coll. Cardiol., November 1, 1998; 32(5): 1426 - 1432.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. L. Cohen, J. Cheirif, D. S. Segar, L. D. Gillam, J. S. Gottdiener, E. Hausnerova, and D. E. Bruns
Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent: Results of a phase III multicenter trial
J. Am. Coll. Cardiol., September 1, 1998; 32(3): 746 - 752.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. A. Grayburn, J. L. Weiss, T. C. Hack, E. Klodas, J. S. Raichlen, M. A. Vannan, A. L. Klein, D. W. Kitzman, S. G. Chrysant, J. L. Cohen, et al.
Phase III multicenter trial comparing the efficacy of 2% dodecafluoropentane emulsion (EchoGen) and sonicated 5% human albumin (Albunex) as ultrasound contrast agents in patients with suboptimal echocardiograms
J. Am. Coll. Cardiol., July 1, 1998; 32(1): 230 - 236.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Kaul
Myocardial Contrast Echocardiography : 15 Years of Research and Development
Circulation, November 18, 1997; 96(10): 3745 - 3760.
[Full Text]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. Aronson
Myocardial Contrast Echocardiography: Is it Ready to be Used as a Clinical Tool in the Operating Room?
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1997; 1(1): 4 - 15.
[PDF]


Home page
CirculationHome page
H. Feigenbaum
Evolution of Echocardiography
Circulation, April 1, 1996; 93(7): 1321 - 1327.
[Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1990 by the American College of Cardiology Foundation.