Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1990; 15:602-609
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shapiro
Right arrow Articles by Meltzer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shapiro, , JR
Right arrow Articles by Meltzer, R.

Reproducibility of quantitative myocardial contrast echocardiography

Shapiro JR, SA Reisner, AF Amico, PF Kelly, and RS Meltzer

Department of Anesthesiology, University of Rochester, New York.

To determine whether myocardial contrast echocardiography is quantitatively reproducible, repeated intracoronary injections of sonicated albumin (5%) were performed in eight open chest dogs. Paired injections were performed at baseline, during ischemia produced by ligation of a coronary artery, and during hyperemia induced by intravenous infusion of 0.75 mg/kg body weight of dipyridamole. Contrast washout curves were generated for the left anterior descending coronary artery territory (ischemic area) and left circumflex coronary artery territory (nonischemic area) by beat per beat analysis of frozen end-diastolic frames of left ventricular short-axis views. Peak contrast intensity, contrast washout half-time and area under the curve were derived from these curves. A total of 75 contrast washout curves were analyzed for the study of interinjection, intraobserver and interobserver reproducibility. The correlation coefficients between measurements obtained from paired injections of the echocardiographic contrast agent (interinjection reproducibility) ranged from 0.78 for peak contrast intensity to 0.87 for area under the curve. Percent error varied between 14.7% and 24.7%. The intraobserver variability in measurements was less than the interinjection variability, with a cumulative mean percent error of 17.8% and correlation coefficients of 0.72 (peak contrast intensity), 0.95 (area under the curve) and 0.96 (washout half-time). Interobserver correlation for all indexes was high (r = 0.92 to 0.96). It is concluded that peak contrast intensity, contrast washout half-time and the area under the curve derived from myocardial contrast washout curves can be measured reproducibly from videotapes. In addition, the variability between two injections attempted under identical conditions is greater than reader variability from videotapes.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
T. Sakuma, Y. Hayashi, K. Sumii, M. Imazu, and M. Yamakido
Prediction of short- and intermediate-term prognoses of patients with acute myocardial infarction using myocardial contrast echocardiography one day after recanalization
J. Am. Coll. Cardiol., October 1, 1998; 32(4): 890 - 897.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
A. D. Waggoner, V. G. Davila-Roman, B. Barzilai, and J. E. Perez
Contrast Two-Dimensional Echocardiography Provides Clinical Information Not Available with Color Flow Imaging
Journal of Diagnostic Medical Sonography, January 1, 1992; 8(1): 2 - 13.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement