Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1990; 15:131-139
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fusejima, K
Right arrow Articles by Inagaki, Y
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fusejima, K
Right arrow Articles by Inagaki, Y

Comparison of coronary hemodynamics in patients with internal mammary artery and saphenous vein coronary artery bypass grafts: a noninvasive approach using combined two-dimensional and Doppler echocardiography

K Fusejima, Y Takahara, Y Sudo, H Murayama, Y Masuda, and Y Inagaki

Department of Cardiology, Chiba Prefectural Tsurumai Hospital, Japan.

Blood flow in bypass grafts and recipient left anterior descending coronary arteries was evaluated with combined two-dimensional and Doppler echocardiography in 15 patients with an internal mammary artery graft and in 24 patients with a saphenous vein graft. Comparative studies of coronary hemodynamics were also performed regarding these two different grafting techniques. The graft vessel was detected in 11 (79%) of 14 patients with an internal mammary artery graft and in 20 (87%) of 23 with a saphenous vein graft. The recipient left anterior descending coronary artery was detected in 10 (67%) of the former group and 17 (71%) of the latter. The blood flow patterns obtained were generally biphasic, consisting of systolic and diastolic phases with higher velocity during diastole. The maximal diastolic flow velocity in internal mammary artery grafts was much higher than that in saphenous vein grafts. In patients with an internal mammary artery graft, the flow pattern characteristics within the recipient coronary artery were quite similar to those within the arterial graft, and flow velocities within the recipient coronary artery and the arterial graft were quantitatively almost identical. This outcome may contribute to the long-term patency seen in internal mammary artery grafts. On the other hand, the flow velocity in saphenous vein grafts was fairly low throughout the cardiac cycle. Flow velocity in the recipient coronary artery in patients with a saphenous vein graft was accelerated only in early diastole. As a result, the recipient coronary artery flow pattern and velocity differed substantially from those in the saphenous vein graft.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Eur J Cardiothorac SurgHome page
C. M. Jones, A. Thanos, P. P. Tekkis, V. Malinovski, S. Purkayastha, A. Haq, J. Kokotsakis, and A. Darzi
Does Doppler echography have a diagnostic role in patency assessment of internal thoracic artery grafts?
Eur J Cardiothorac Surg, November 1, 2005; 28(5): 692 - 700.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Yoshitatsu, Y. Miyamoto, M. Mitsuno, K. Toda, M. Yoshikawa, S. Fukui, F. Nomura, N. Hirata, and K. Onishi
Changes in left anterior descending coronary artery flow profiles after coronary artery bypass grafting examined by means of transthoracic Doppler echocardiography
J. Thorac. Cardiovasc. Surg., November 1, 2003; 126(5): 1531 - 1536.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. Hirata, N. Asaoka, A. Amemiya, S. Hatsuoka, T. Ueno, and Y. Kosakai
Noninvasive evaluation of internal thoracic artery and left anterior descending coronary artery anastomotic sites using transthoracic Doppler echocardiography: comparison with coronary arteriography
J. Thorac. Cardiovasc. Surg., October 1, 2003; 126(4): 1080 - 1086.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
K.-J. Yoo, D. Choi, B. W. Choi, S.-H. Lim, and B.-C. Chang
The comparison of the graft patency after coronary artery bypass grafting using coronary angiography and multi-slice computed tomography
Eur J Cardiothorac Surg, July 1, 2003; 24(1): 86 - 91.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
T. A Abdel Aziz, P. Kumar, N. Bazargani, E. Al-Hato, and N. Al Khaja
Assessment of Coronary Bypass Graft Patency by Electron-Beam Computed Tomography
Asian Cardiovasc Thorac Ann, June 1, 2003; 11(2): 102 - 106.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T.-P. Tsai, K.-C. Ueng, J.-M. Yu, Y.-C. Chang, and Y.-L. Wu
Comparison of the Postoperative Blood Flow Waveforms of the Bypassing Grafts in Patients Following Minimally Invasive Direct Coronary Artery Bypass
Chest, March 1, 2002; 121(3): 951 - 956.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
F Chirillo, A Bruni, G Balestra, C Cavallini, Z Olivari, J D Thomas, and P Stritoni
Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography
Heart, October 1, 2001; 86(4): 424 - 431.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Ishida, H. Sakuma, B. P. Cruz, T. Shimono, T. Tokui, I. Yada, K. Takeda, and C. B. Higgins
MR Flow Measurement in the Internal Mammary Artery-to-Coronary Artery Bypass Graft: Comparison with Graft Stenosis at Radiographic Angiography
Radiology, August 1, 2001; 220(2): 441 - 447.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. E. Langerak, P. Kunz, H. W. Vliegen, H. J. Lamb, J. W. Jukema, E. E. van der Wall, and A. de Roos
Improved MR Flow Mapping in Coronary Artery Bypass Grafts during Adenosine-induced Stress
Radiology, February 1, 2001; 218(2): 540 - 547.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
J. C. Lin, D. L. Fisher, M. F. Szwerc, and J. A. Magovern
Evaluation of graft patency during minimally invasive coronary artery bypass grafting with Doppler flow analysis
Ann. Thorac. Surg., October 1, 2000; 70(4): 1350 - 1354.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Shimizu, T. Hirayama, H. Suesada, K. Ikeda, S. Ito, and S. Ishimaru
Effect of flow competition on internal thoracic artery graft: Postoperative velocimetric and angiographic study
J. Thorac. Cardiovasc. Surg., September 1, 2000; 120(3): 459 - 465.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. De Paulis, F. Tomai, A. Gaspardone, L. Colagrande, P. Nardi, A. Ghini, F. Versaci, A. P. de Peppo, P. A. Gioffre, and L. Chiariello
CORONARY FLOW RESERVE EARLY AND LATE AFTER MINIMALLY INVASIVE CORONARY ARTERY BYPASS GRAFTING IN PATIENTS WITH TOTALLY OCCLUDED LEFT ANTERIOR DESCENDING CORONARY ARTERY
J. Thorac. Cardiovasc. Surg., October 1, 1999; 118(4): 604 - 609.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Tavilla, N. H.J. Pijls, E. Berreklouw, and K. H. Peels
Noninvasive assessment of right gastroepiploic artery graft patency using transcutaneous color Doppler echocardiography
Ann. Thorac. Surg., March 1, 1999; 67(3): 624 - 628.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Oda, K. Hirose, H. Nishimori, K. Sato, T. Yamashiro, and S. Ogoshi
Assessment of internal thoracic artery graft with intraoperative color doppler ultrasonography
Ann. Thorac. Surg., July 1, 1998; 66(1): 79 - 81.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Tasdemir, U. Kiziltepe, H. Y. Karagoz, B. Yamak, S. Korkmaz, and K. Bayazit
LONG-TERM RESULTS OF RECONSTRUCTIONS OF THE LEFT ANTERIOR DESCENDING CORONARY ARTERY IN DIFFUSE ATHEROSCLEROTIC LESIONS
J. Thorac. Cardiovasc. Surg., September 1, 1996; 112(3): 745 - 754.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Cartier, O. S. Dias, M. Pellerin, Y. Hebert, and Y. Leclerc
CHANGING FLOW PATTERN OF THE INTERNAL THORACIC ARTERY UNDERGOING CORONARY BYPASS GRAFTING: CONTINUOUS-WAVE DOPPLER ASSESSMENT
J. Thorac. Cardiovasc. Surg., July 1, 1996; 112(1): 52 - 58.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
H. Takemura, M. Kawasuji, N. Sakakibara, T. Tedoriya, T. Ushijima, and Y. Watanabe
Internal Thoracic Artery Graft Function During Exercise Assessed by Transthoracic Doppler Echography
Ann. Thorac. Surg., March 1, 1996; 61(3): 914 - 919.
[Abstract] [Full Text]


Home page
CirculationHome page
M. A. Galjee, A. C. van Rossum, T. Doesburg, M. J. van Eenige, and C. A. Visser
Value of Magnetic Resonance Imaging in Assessing Patency and Function of Coronary Artery Bypass Grafts : An Angiographically Controlled Study
Circulation, February 15, 1996; 93(4): 660 - 666.
[Abstract] [Full Text]


Home page
CirculationHome page
J. J. Crowley and L. M. Shapiro
Noninvasive Assessment of Left Internal Mammary Artery Graft Patency Using Transthoracic Echocardiography
Circulation, November 1, 1995; 92(9): 25 - 30.
[Abstract] [Full Text]


Home page
VASC ENDOVASCULAR SURGHome page
M. Ciccone, D. di Noia, F. Corriero, A. Federici, and P. Rizzon
Noninvasive Estimation of the Internal Mammary Artery Bypass Graft Patency: A Six-Year Follow-up
Vascular and Endovascular Surgery, November 1, 1994; 28(9): 601 - 606.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. M. van Son, S. H. Skotnicki, M. B. M. Peters, N. H. J. Pijls, L. Noyez, and W. N. J. C. van Asten
Noninvasive hemodynamic assessment of the internal mammary artery in myocardial revascularization
Ann. Thorac. Surg., February 1, 1993; 55(2): 404 - 409.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. M. van Son, S. H. Skotnicki, H. A. Folmer, and W. N. J. C. van Asten
Reactive hyperemia in the nonused internal mammary artery after median sternotomy
Ann. Thorac. Surg., July 1, 1992; 54(1): 130 - 133.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement