J Am Coll Cardiol, 1990; 15:119-127
© 1990 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Walsh, M.
Right arrow Articles by Bergmann
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Walsh, M.
Right arrow Articles by Bergmann, , SR

Augmented myocardial perfusion reserve after coronary angioplasty quantified by positron emission tomography with H2(15)O

MN Walsh, EM Geltman, RL Steele, JL Kenzora, PA Ludbrook, BE Sobel, and Bergmann SR

Cardiovascular Division, Washington University School of Medicine, St. Louis, Missouri 63110.

Effects of coronary angioplasty on myocardial flow reserve have been difficult to characterize noninvasively because conventional imaging techniques cannot quantitate blood flow in absolute terms. The effects of coronary angioplasty on myocardial perfusion and perfusion reserve were delineated with positron emission tomography and oxygen-15-labeled water (H2(15)O) in 13 patients before and after single vessel angioplasty. In 11 patients, angioplasty was successful (minimal cross-sectional area increased from 0.60 +/- 0.59 to 3.45 +/- 1.09 mm2, p less than 0.001). In these patients, regional H2(15)O radioactivity (the ratio of nutritional perfusion in regions distal to the stenosis compared with regions supplied by angiographically normal arteries) at rest before angioplasty was 55 +/- 22% of peak myocardial radioactivity and did not increase significantly afterward (70 +/- 16%, p = NS). However, after administration of intravenous dipyridamole, hyperemic perfusion in regions distal to a stenosis averaged only 39 +/- 18% of peak myocardial counts before angioplasty, but increased to 66 +/- 22% after angioplasty (p less than 0.02). Perfusion reserve in the two patients in whom angioplasty was angiographically unsuccessful showed no change. Quantitative estimates of perfusion in absolute rather than relative terms were obtained with positron emission tomographic data from seven of the patients with successful angioplasty. At rest, perfusion in regions distal to a stenosis was not different from the values in regions supplied by normal coronary arteries (1.54 +/- 0.54 compared with 1.46 +/- 0.38 ml/g per min, p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S.-Y. Chung, K.-Y. Lee, E. J. Chun, W.-W. Lee, E. K. Park, H.-J. Chang, and S. I. Choi
Comparison of Stress Perfusion MRI and SPECT for Detection of Myocardial Ischemia in Patients With Angiographically Proven Three-Vessel Coronary Artery Disease
Am. J. Roentgenol., August 1, 2010; 195(2): 356 - 362.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Ishida, H. Sakuma, N. Kato, N. Ishida, K. Kitagawa, T. Shimono, I. Yada, and K. Takeda
Contrast-enhanced MR Imaging for Evaluation of Coronary Artery Disease before Elective Repair of Aortic Aneurysm
Radiology, November 1, 2005; 237(2): 458 - 464.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. A. Kaufmann and P. G. Camici
Myocardial Blood Flow Measurement by PET: Technical Aspects and Clinical Applications
J. Nucl. Med., January 1, 2005; 46(1): 75 - 88.
[Full Text] [PDF]


Home page
RadiologyHome page
N. Ishida, H. Sakuma, M. Motoyasu, T. Okinaka, N. Isaka, T. Nakano, and K. Takeda
Noninfarcted Myocardium: Correlation between Dynamic First-Pass Contrast-enhanced Myocardial MR Imaging and Quantitative Coronary Angiography
Radiology, October 1, 2003; 229(1): 209 - 216.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
N. Al-Saadi, E. Nagel, M. Gross, B. Schnackenburg, I. Paetsch, C. Klein, and E. Fleck
Improvement of myocardial perfusion reserve early after coronary intervention: assessment with cardiac magnetic resonance imaging
J. Am. Coll. Cardiol., November 1, 2000; 36(5): 1557 - 1564.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
I. Kosa, R. Blasini, J. Schneider-Eicke, T. Dickfeld, F. J. Neumann, S. Ziegler, I. Matsunari, J. Neverve, A. Schomig, and M. Schwaiger
Early recovery of coronary flow reserve after stent implantation as assessed by positron emission tomography
J. Am. Coll. Cardiol., October 1, 1999; 34(4): 1036 - 1041.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. M. van Liebergen, J. J. Piek, K. T. Koch, R. J. de Winter, and K. I. Lie
Immediate and Long-Term Effect of Balloon Angioplasty or Stent Implantation on the Absolute and Relative Coronary Blood Flow Velocity Reserve
Circulation, November 17, 1998; 98(20): 2133 - 2140.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. P. Donnelly, D. M. Raffel, B. L. Shulkin, J. R. Corbett, E. L. Bove, R. S. Mosca, and T. J. Kulik
Resting coronary flow and coronary flow reserve in human infants after repair or palliation of congenital heart defects as measured by positron emission tomography
J. Thorac. Cardiovasc. Surg., January 1, 1998; 115(1): 103 - 110.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. D. Miller, T. J. Donohue, T. L. Wolford, M. J. Kern, S. R. Bergmann, C. M. Mechem, and J. J. Hartman
Assessment of Blood Flow Distal to Coronary Artery Stenoses: Correlations Between Myocardial Positron Emission Tomography and Poststenotic Intracoronary Doppler Flow Reserve
Circulation, November 15, 1996; 94(10): 2447 - 2454.
[Abstract] [Full Text]



 