Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1989; 14:1283-1289
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kay, G.
Right arrow Articles by Plumb, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kay, G.
Right arrow Articles by Plumb, V.

Rate-modulated cardiac pacing based on transthoracic impedance measurements of minute ventilation: correlation with exercise gas exchange

GN Kay, RS Bubien, AE Epstein, and VJ Plumb

Department of Medicine, University of Alabama, Birmingham 35294.

The relation of pacing rate to physiologic variables of metabolic demand was examined in 10 consecutive patients with a minute ventilation-sensing, rate-modulating ventricular pacemaker implanted for complete heart block. All patients had paroxysmal (seven patients) or chronic (three patients) atrial fibrillation and were referred for catheter ablation of the atrioventricular junction. Treadmill exercise testing with measurement of expired gas exchange and respiratory flow was performed before ablation and 4 weeks after pacemaker implantation, with the pacemaker programmed to both the fixed-rate VVI and rate-modulating minute ventilation VVIR pacing modes in random sequence. The relation of pacing rate to oxygen consumption (VO2), expired carbon dioxide concentration (VCO2), respiratory quotient, tidal volume, respiratory rate and minute ventilation was determined during exercise in the rate-modulating minute ventilation pacing mode. Pacing rate was highly correlated with minute ventilation (r = 0.89), respiratory quotient (r = 0.89), VCO2 (r = 0.87), tidal volume (r = 0.87), VO2 (r = 0.84) and respiratory rate (r = 0.84). The mean exercise duration increased from 8.3 +/- 2.8 min in the fixed rate pacing mode to 10.2 +/- 3.4 min in the rate-modulating, minute ventilation mode (p = 0.0001). The maximal VO2 increased from 13.4 +/- 3.4 to 16.3 +/- 4.1 cc/kg per min (p = 0.0004). The maximal heart rate achieved in the minute ventilation pacing mode was 136 +/- 9.7 beats/min, similar to that observed in the patient's intrinsic cardiac rhythm before ablation (134.9 +/- 30.1 beats/min, p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Card Surg AdultHome page
H. M. Spotnitz
Surgical Implantation of Pacemakers and Automatic Defibrillators
Card. Surg. Adult, January 1, 2008; 3(2008): 1395 - 1428.
[Full Text]


Home page
Card Surg AdultHome page
H. M. Spotnitz
Pacemakers and Automatic Defibrillators
Card. Surg. Adult, January 1, 2003; 2(2003): 1293 - 1326.
[Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement