JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1989; 14:499-507
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Janosik, D.
Right arrow Articles by Redd, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Janosik, D.
Right arrow Articles by Redd, R.

The hemodynamic benefit of differential atrioventricular delay intervals for sensed and paced atrial events during physiologic pacing

DL Janosik, AC Pearson, TA Buckingham, AJ Labovitz, and RM Redd

Department of Internal Medicine, St. Louis University Medical Center, Missouri 63110.

The ability to program different atrioventricular (AV) delay intervals for paced and sensed atrial events is incorporated in the design of some newer dual chamber pacemakers. However, little is known regarding the hemodynamic benefit of differential AV delay intervals or the magnitude of difference between optimal AV delay intervals for paced and sensed P waves in individual patients. In this study, Doppler-derived cardiac output was used to examine the optimal timing of paced and sensed atrial events in 24 patients with a permanent dual chamber pacemaker. The hemodynamic effect of utilizing separate optimal delay intervals for sensed and paced events compared with utilizing the same fixed AV delay interval for both was determined. The optimal delay interval during DVI (AV sequential) pacing and VDD (atrial triggered, ventricular inhibited) pacing at similar heart rates was 176 +/- 44 and 144 +/- 48 ms (p less than 0.002), respectively. The mean difference between the optimal AV delay intervals for sensed (VDD) and paced (DVI) P waves was 32 ms and was up to 100 ms in some individuals. The difference between optimal AV delay intervals for sensed and paced atrial events was similar in patients with complete heart block and those with intact AV node conduction. At the respective optimal AV delay intervals for sensed and paced P waves, there was no significant difference in the cardiac output during VDD compared with DVI pacing. However, cardiac output significant declined during VDD pacing at the optimal AV delay interval for a paced event and during DVI pacing at the optimal interval for a sensed event.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
M. H. Schoenfeld
Contemporary Pacemaker and Defibrillator Device Therapy: Challenges Confronting the General Cardiologist
Circulation, February 6, 2007; 115(5): 638 - 653.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Bernheim, P. Ammann, C. Sticherling, P. Burger, B. Schaer, H. P. Brunner-La Rocca, J. Eckstein, S. Kiencke, C. Kaiser, A. Linka, et al.
Right Atrial Pacing Impairs Cardiac Function During Resynchronization Therapy: Acute Effects of DDD Pacing Compared to VDD Pacing
J. Am. Coll. Cardiol., May 3, 2005; 45(9): 1482 - 1487.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
P. Chandra, T. S Rosen, B. Herweg, P. Danilo Jr., and M. R Rosen
Left atrial pacing induces memory and is associated with atrial tachyarrhythmias
Cardiovasc Res, November 1, 2003; 60(2): 307 - 314.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. E. Maurer, B. Naegeli, E. Straumann, O. Bertel, and J. Frielingsdorf
Quality of life and exercise capacity in patients with prolonged PQ interval and dual chamber pacemakers: a randomized comparison of permanent ventricular stimulation vs intrinsic AV conduction
Europace, January 1, 2003; 5(4): 411 - 417.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
T. Levy, G.H. Jenkins, S. Walker, L. Grieve, C. Webb, M.G. Buckley, D.R.J. Singer, and V. Paul
Does the mechanism of action of biatrial pacing for atrial fibrillation involve changes in cardiac haemodynamics?: Assessment by Doppler echocardiography and natriuretic peptide measurements
Europace, January 1, 2000; 2(2): 127 - 135.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
B. Schwaab, G. Frohlig, C. Alexander, M. Kindermann, N. Hellwig, H. Schwerdt, C.-M. Kirsch, and H. Schieffer
Influence of right ventricular stimulation site on left ventricular function in atrial synchronous ventricular pacing
J. Am. Coll. Cardiol., February 1, 1999; 33(2): 317 - 323.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J.C. Nielsen, A.K. Pedersen, P.T. Mortensen, and H.R. Andersen
Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome
Europace, January 1, 1999; 1(2): 113 - 120.
[Abstract] [PDF]


Home page
EuropaceHome page
E. Crystal and I. Eli Ovsyshcher
Cardiac output-based versus empirically programmed AV interval -- how different are they?
Europace, January 1, 1999; 1(2): 121 - 125.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1989 by the American College of Cardiology Foundation.