Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1989; 14:165-171
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bardy, G.
Right arrow Articles by Greene, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bardy, G.
Right arrow Articles by Greene, H.

Prospective comparison of sequential pulse and single pulse defibrillation with use of two different clinically available systems

GH Bardy, TD Ivey, MD Allen, G Johnson, and HL Greene

Department of Medicine, University of Washington, Seattle.

Sixteen out-of-hospital survivors of ventricular fibrillation underwent a prospective, randomized, intraoperative comparison of sequential pulse and single pulse defibrillation with use of two distinct electrode systems and waveform shapes currently available for clinical use. Defibrillation was tested alternately with either the single pulse or the sequential pulse system 10 s into an episode of ventricular fibrillation. Sequential pulse defibrillation was performed with two 4 ms truncated exponential pulses of constant duration delivered to three equally spaced oval epicardial patch electrodes composed of concentric coils. The posterior left ventricular electrode served as the common cathode. The first anode was over the anterior right ventricle and the second anode was over the anterior left ventricle. Single pulse defibrillation was performed with the standard intracardiac defibrillation system with use of a single truncated exponential pulse with a fixed 65% tilt delivered across two rectangular, wire mesh epicardial patch electrodes positioned over the anterior right ventricle and posterolateral left ventricle. During defibrillation threshold determination, voltage and current waveforms were recorded and used to determine pulsing resistance and delivered and stored energy. Average defibrillation threshold leading edge voltage for the single pulse technique was 273 +/- 101 V compared with 246 +/- 67 V (11% less) for the sequential pulse technique (p = 0.136). Defibrillation threshold leading edge current for the single pulse technique was 6.7 +/- 2.5 A compared with 5.2 +/- 1.7 A (29% less) for the sequential pulse method (p = 0.005). The defibrillation threshold delivered energy was 5.6 +/- 4.0 J for the single pulse technique and 3.5 +/- 1.8 J (38% less) for the sequential pulse technique (p = 0.021).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
R. A. S. Cooper, V. J. Plumb, A. E. Epstein, G. N. Kay, and R. E. Ideker
Marked Reduction in Internal Atrial Defibrillation Thresholds With Dual-Current Pathways and Sequential Shocks in Humans
Circulation, June 30, 1998; 97(25): 2527 - 2535.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. S. Cooper, W. M. Smith, and R. E. Ideker
Internal Cardioversion of Atrial Fibrillation : Marked Reduction in Defibrillation Threshold With Dual Current Pathways
Circulation, October 21, 1997; 96(8): 2693 - 2700.
[Abstract] [Full Text]


Home page
CirculationHome page
G. H. Bardy, J. E. Poole, P. J. Kudenchuk, G. L. Dolack, R. Mehra, P. DeGroot, M. H. Raitt, G. K. Jones, and G. Johnson
A Prospective Randomized Comparison in Humans of Biphasic Waveform 60- F and 120- F Capacitance Pulses Using A Unipolar Defibrillation System
Circulation, January 1, 1995; 91(1): 91 - 95.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement