JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1989; 13:1672-1681
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krabill, K.
Right arrow Articles by Sahn, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krabill, K.
Right arrow Articles by Sahn, D.

Factors influencing the structure and shape of stenotic and regurgitant jets: an in vitro investigation using Doppler color flow mapping and optical flow visualization

KA Krabill, HW Sung, T Tamura, KJ Chung, AP Yoganathan, and DJ Sahn

Department of Pediatrics, University of California, San Diego.

To evaluate factors influencing the structure and shape of stenotic and regurgitant jets, Doppler color flow mapping and optical flow visualization studies were performed with use of a syringe model with a constant rate of ejection to simulate jets of valvular regurgitation and a pulsatile flow model of the right heart chambers to simulate jets of mild, moderate and severe valvular pulmonary stenosis. Ink-(0 to 40%) glycerol-water jets (viscosity 1 to 3.5 centiPoise) were produced by injecting the fluid at a constant rate into a 10 gallon rectangular reservoir of the same still fluid through 1.4 and 3.4 mm needles. The Doppler color flow scanners imaged the laminar jet length within 3 mm of actual jet length (2 to 6 cm) and the jet width within 2 to 3 mm of the actual jet width. Jet flows with Reynolds numbers ranging from 230 to 1,200 injected into still fluid yielded jet length/width ratios that decreased with increasing Reynolds numbers and leveled off to a length/width ratio of 5-6:1 at a Reynolds number near 600. When the fluid reservoir was swirled to better mimic the effect of flow entering the same cardiac chamber from a second source, the jets showed diminution of the jet length/width ratio and a clearly defined zone of turbulence. Studies of the pulsatile flow model were performed at cardiac outputs of 1 to 6 liters/min for the normal and each stenotic valve. Mild stenosis had an orifice area of 2.8 cm2, moderate stenosis an area of 1.0 cm2 and severe stenosis an area of 0.5 cm2. Laminar jet length represented the length of the total jet, which had a symmetric width and was measured from the valve opening to a region where the jet exhibited a spray effect. Laminar jet lengths (0.2 to 1.1 cm) were imaged by Doppler color flow mapping and optical visualization only in the moderate and severely stenotic valves and only at flows less than or equal to 3 liters/min (mean Reynolds numbers less than or equal to 3,470). Beyond this flow rate the jets exhibited a spray effect. Laminar jet length/width ratio approached unity with an increased amount of valvular stenosis and higher flow volumes (cardiac output). Proximal aliasing was present in each valve studied. the length of aliasing (0 to 3.2 cm) proximal to the valve was longer with increased flow rates and increased amounts of stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)


This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. J. Weiss and J. S. Savino
What Is the Best Way to Assess Mitral Regurgitation?
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1997; 1(1): 49 - 60.
[PDF]


Home page
CirculationHome page
B. Diebold, A. Delouche, P. Delouche, J.-P. Guglielmi, P. Dumee, and A. Herment
In Vitro Flow Mapping of Regurgitant Jets: Systematic Description of Free Jet With Laser Doppler Velocimetry
Circulation, July 15, 1996; 94(2): 158 - 169.
[Abstract] [Full Text]


Home page
CirculationHome page
D. Mele, P. Vandervoort, I. Palacios, J. M. Rivera, R. E. Dinsmore, E. Schwammenthal, J. E. Marshall, A. E. Weyman, and R. A. Levine
Proximal Jet Size by Doppler Color Flow Mapping Predicts Severityof Mitral Regurgitation : Clinical Studies
Circulation, February 1, 1995; 91(3): 746 - 754.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1989 by the American College of Cardiology Foundation.