J Am Coll Cardiol, 1989; 13:1382-1392 © 1989 by the American College of Cardiology Foundation |
Stanford University School of Medicine, California.
A newly developed, flow-directed, Doppler pulmonary artery catheter, capable of measuring instantaneous and continuous cardiac output, was evaluated in both an in vitro pump model and an animal model. Quantitative flow was calculated with use of the instantaneous, space-average velocity (obtained from the velocity profile) and the instantaneous area (obtained from the vessel diameter) and compared with electromagnetic flow. Additionally, simultaneous thermodilution flow measurements were obtained. Doppler catheter-determined flow was highly predictive of electromagnetic flow in both continuous and pulsatile pump models (r2 = 0.98, slope or m = 1.04, SEE = 0.44; and r2 = 0.97, m = 1.04 and SEE = 0.33, respectively). Thermodilution was less predictive and appeared to underestimate electromagnetic flow in both the continuous and the pulsatile model (r2 = 0.99, m = 0.91, SEE = 0.20 and r2 = 0.95, m = 0.84 and SEE = 0.34, respectively). In the animal model, Doppler catheter-determined cardiac output appeared to modestly underestimate electromagnetic flow (r2 = 0.80, m = 0.87, SEE = 0.61). However, Doppler determinations of flow remained more accurate than did simultaneous thermodilution measurements (r2 = 0.73, m = 0.79, SEE = 0.72). Accurate, continuous and instantaneous cardiac output measurements appear possible with use of a flow-directed, Doppler pulmonary artery catheter. This catheter system also provides instantaneous diameter measurements and mapping of instantaneous velocity profiles within the main pulmonary artery and may lead to more accurate Doppler-derived assessment of cardiac output in humans.
This article has been cited by other articles:
![]() |
V. K. Dhingra, J. C. Fenwick, K. R. Walley, D. R. Chittock, and J. J. Ronco Lack of Agreement Between Thermodilution and Fick Cardiac Output in Critically Ill Patients* Chest, September 1, 2002; 122(3): 990 - 997. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. S. Mueller, K. Chatterjee, K. B. Davis, M. A. Fifer, C. Franklin, M. A. Greenberg, A. J. Labovitz, P. K. Shah, K. J. Tuman, M. H. Weil, et al. Present use of bedside right heart catheterization in patients with cardiac disease J. Am. Coll. Cardiol., September 1, 1998; 32(3): 840 - 864. [Full Text] [PDF] |
||||
![]() |
E. Sloth, M. Kruse, K. C Houlind, E. M Pedersen, and J.M. Hasenkam The impact of ischemic heart disease on main pulmonary artery blood flow patterns: a comparison between magnetic resonance phase velocity mapping and transesophageal color Doppler Cardiovasc Res, December 1, 1997; 36(3): 377 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Sloth, K. C. Houlind, E. M. Pedersen, and J.M. Hasenkam Where to place the Doppler sample volume in the human main pulmonary artery: evaluated from magnetic resonance phase velocity maps Cardiovasc Res, January 1, 1997; 33(1): 156 - 163. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Voyce and J. M. Rippe Pulmonary Artery Catheters: An Update J Intensive Care Med, July 1, 1990; 5(4): 175 - 192. [Abstract] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |