Long-term outcome with the automatic implantable cardioverter-defibrillator
RA Winkle,
RH Mead,
MA Ruder,
VA Gaudiani,
NA Smith,
WS Buch,
P Schmidt,
and
T Shipman
Department of Cardiology and Cardiovascular Surgery, Sequoia Hospital, Redwood City, California.
The automatic implantable cardioverter-defibrillator was implanted in 270 patients because of life-threatening arrhythmias over a 7 year period. There was a history of sustained ventricular tachycardia or fibrillation, or both, in 96% of these patients, 80% had one or more prior cardiac arrests and 78% had coronary artery disease as their underlying diagnosis. The average ejection fraction was 34%, and 96% of these patients had had an average of 3.4 antiarrhythmic drug failures per patient before defibrillator implantation. There were four perioperative deaths and eight patients had generator infection or generator erosion, or both, during the perioperative period or during long-term follow-up. Concomitant antiarrhythmic drug therapy was given to 69% of patients. Shocks from the device were given to 58% of patients. and 20% received "problematic" shocks. The device was removed from 16 patients during long-term follow-up for a variety of reasons. There were 7 sudden cardiac deaths and 30 nonsudden cardiac deaths, 18 of which were secondary to congestive heart failure. The actuarial incidence of sudden death, total cardiac death and total mortality from all causes was 1%, 7% and 8%, respectively, at 1 year, and 4%, 24% and 26% at 5 years. The automatic implantable cardioverter-defibrillator nearly eliminates sudden death over a long-term follow-up period in a high risk group of patients. It has an acceptable rate of complications or problems, or both, and most late deaths in these patients are nonsudden and of cardiovascular origin.
This article has been cited by other articles:

|
 |

|
 |
 
H. M. Spotnitz
Surgical Implantation of Pacemakers and Automatic Defibrillators
Card. Surg. Adult,
January 1, 2008;
3(2008):
1395 - 1428.
[Full Text]
|
 |
|

|
 |

|
 |
 
C. Perings, G. Klein, E. Toft, C. Moro, D. Klug, D. Bocker, H.J. Trappe, T. Korte, and on behalf of the RIONI Investigators
The RIONI study rationale and design: validation of the first stored electrograms transmitted via home monitoring in patients with implantable defibrillators.
Europace,
April 1, 2006;
8(4):
288 - 292.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Kadish and M. Mehra
Heart Failure Devices: Implantable Cardioverter-Defibrillators and Biventricular Pacing Therapy
Circulation,
June 21, 2005;
111(24):
3327 - 3335.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Cappato, S. Boczor, K.-H. Kuck, and on behalf of the CASH Investigators
Response to programmed ventricular stimulation and clinical outcome in cardiac arrest survivors receiving randomised assignment to implantable cardioverter defibrillator or antiarrhythmic drug therapy
Eur. Heart J.,
April 2, 2004;
25(8):
642 - 649.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. P. DiMarco
Implantable Cardioverter-Defibrillators
N. Engl. J. Med.,
November 6, 2003;
349(19):
1836 - 1847.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. M. Spotnitz
Pacemakers and Automatic Defibrillators
Card. Surg. Adult,
January 1, 2003;
2(2003):
1293 - 1326.
[Full Text]
|
 |
|

|
 |

|
 |
 
Committee Members, G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, et al.
ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices--Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
J. Am. Coll. Cardiol.,
November 6, 2002;
40(9):
1703 - 1719.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, M. J. Silka, et al.
ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
Circulation,
October 15, 2002;
106(16):
2145 - 2161.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. B. Mitchell, E. A. Pineda, J. L. Titus, P. M. Bartosch, and D. G. Benditt
Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation
J. Am. Coll. Cardiol.,
April 17, 2002;
39(8):
1323 - 1328.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. A. Mowrey, Y. Cheng, P. J. Tchou, and I. R. Efimov
Kinetics of defibrillation shock-induced response: design implications for the optimal defibrillation waveform
Europace,
January 1, 2002;
4(1):
27 - 39.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. J. Rashba, M. R. Olsovsky, S. R. Shorofsky, M. M. Kirk, R. W. Peters, and M. R. Gold
Temporal decline in defibrillation thresholds with an active pectoral lead system
J. Am. Coll. Cardiol.,
October 1, 2001;
38(4):
1150 - 1155.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S.G. Priori, E. Aliot, C. Blomstrom-Lundqvist, L. Bossaert, G. Breithardt, P. Brugada, A.J. Camm, R. Cappato, S.M. Cobbe, C. Di Mario, et al.
Task Force on Sudden Cardiac Death of the European Society of Cardiology
Eur. Heart J.,
August 2, 2001;
22(16):
1374 - 1450.
[PDF]
|
 |
|

|
 |

|
 |
 
S. Nisam
A Prophylactic ICD? Who are the patients? What is the device?
Europace,
January 1, 2001;
3(4):
269 - 274.
[PDF]
|
 |
|

|
 |

|
 |
 
M. E. Josephson, D. J. Callans, and A. E. Buxton
The Role of the Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death
Ann Intern Med,
December 5, 2000;
133(11):
901 - 910.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K.-H. Kuck, R. Cappato, J. Siebels, and R. Ruppel
Randomized Comparison of Antiarrhythmic Drug Therapy With Implantable Defibrillators in Patients Resuscitated From Cardiac Arrest : The Cardiac Arrest Study Hamburg (CASH)
Circulation,
August 15, 2000;
102(7):
748 - 754.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Korte, W. Jung, G. Ostermann, C. Wolpert, S. Spehl, B. Esmailzadeh, and B. Luderitz
Hospital readmission after transvenous cardioverter/defibrillator implantation. A single centre study
Eur. Heart J.,
July 2, 2000;
21(14):
1186 - 1191.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Katz, R. J. Sweeney, R. M. Gill, P. R. Reid, and E. N. Prystowsky
Relation of Atrial Refractoriness to Upper and Lower Limits of Vulnerability for Atrial Fibrillation/Flutter Following Implantable Ventricular Defibrillator Shocks
Circulation,
September 7, 1999;
100(10):
1125 - 1130.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Cooklin, M. R. Olsovsky, R. G. Brockman, S. R. Shorofsky, and M. R. Gold
Atrial defibrillation with a transvenous lead: A randomized comparison of active can shocking pathways
J. Am. Coll. Cardiol.,
August 1, 1999;
34(2):
358 - 362.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. L. Anderson, A. P. Hallstrom, A. E. Epstein, S. L. Pinski, Y. Rosenberg, M. O. Nora, D. Chilson, D. S. Cannom, and R. Moore
Design and Results of the Antiarrhythmics vs Implantable Defibrillators (AVID) Registry
Circulation,
April 6, 1999;
99(13):
1692 - 1699.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. S. Cannom and E. N. Prystowsky
Management of Ventricular Arrhythmias: Detection, Drugs, and Devices
JAMA,
January 13, 1999;
281(2):
172 - 179.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Ruppel, C. A. Schluter, S. Boczor, T. Meinertz, M. Schluter, K.-H. Kuck, and R. Cappato
Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators
J. Am. Coll. Cardiol.,
November 15, 1998;
32(6):
1724 - 1730.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. Yamanouchi, K. A. Mowrey, M. J. Niebauer, P. J. Tchou, and B. L. Wilkoff
Additional Lead Improves Defibrillation Efficacy With an Abdominal `Hot Can' Electrode System
Circulation,
December 16, 1997;
96(12):
4400 - 4407.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
K. J. Quan, J. H. Lee, O. Costantini, A. K. Konstantakos, H. K. Murrell, M. D. Carlson, J. A. Mackall, L. A. Biblo, and A. S. Geha
Favorable Results of Implantable Cardioverter-Defibrillator Implantation in Patients Older Than 70 Years
Ann. Thorac. Surg.,
December 1, 1997;
64(6):
1713 - 1717.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. T. Bigger and The Coronary Artery Bypass Graft (CABG) Patch Tria
Prophylactic Use of Implanted Cardiac Defibrillators in Patients at High Risk for Ventricular Arrhythmias after Coronary-Artery Bypass Graft Surgery
N. Engl. J. Med.,
November 27, 1997;
337(22):
1569 - 1575.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
The Antiarrhythmics versus Implantable Defibrillat
A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular Arrhythmias
N. Engl. J. Med.,
November 27, 1997;
337(22):
1576 - 1584.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. A. Strickberger, K. C. Man, E. G. Daoud, R. Goyal, K. Brinkman, C. Hasse, F. Bogun, B. P. Knight, R. Weiss, M. Bahu, et al.
A Prospective Evaluation of Catheter Ablation of Ventricular Tachycardia as Adjuvant Therapy in Patients With Coronary Artery Disease and an Implantable Cardioverter-Defibrillator
Circulation,
September 2, 1997;
96(5):
1525 - 1531.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. A. Strickberger, E. G. Daoud, T. Davidson, R. Weiss, F. Bogun, B. P. Knight, M. Bahu, R. Goyal, K. C. Man, and F. Morady
Probability of Successful Defibrillation at Multiples of the Defibrillation Energy Requirement in Patients With an Implantable Defibrillator
Circulation,
August 19, 1997;
96(4):
1217 - 1223.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
M. J. Domanski, D. P. Zipes, and E. Schron
Treatment of Sudden Cardiac Death : Current Understandings From Randomized Trials and Future Research Directions
Circulation,
June 17, 1997;
95(12):
2694 - 2699.
[Full Text]
|
 |
|

|
 |

|
 |
 
R. A. S. Cooper, E. E. Johnson, and J. M. Wharton
Internal Atrial Defibrillation in Humans : Improved Efficacy of Biphasic Waveforms and the Importance of Phase Duration
Circulation,
March 18, 1997;
95(6):
1487 - 1496.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
G. Gioia, B. Bagheri, C. D. Gottlieb, D. S. Schwartzman, D. J. Callans, F. E. Marchlinski, J. Heo, and A. E. Iskandrian
Prediction of Outcome of Patients With Life-Threatening Ventricular Arrhythmias Treated With Automatic Implantable Cardioverter-Defibrillators Using SPECT Perfusion Imaging
Circulation,
January 21, 1997;
95(2):
390 - 394.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. O'Nunain, I. Perez, M. Roelke, S. Osswald, B. A. McGovern, D. R. Brooks, D. F. Torchiana, G. J. Vlahakes, J. Ruskin, and H. Garan
THE TREATMENT OF PATIENTS WITH INFECTED IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEMS
J. Thorac. Cardiovasc. Surg.,
January 1, 1997;
113(1):
121 - 129.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
A. J. Moss, W. J. Hall, D. S. Cannom, J. P. Daubert, S. L. Higgins, H. Klein, J. H. Levine, S. Saksena, A. L. Waldo, D. Wilber, et al.
Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular Arrhythmia
N. Engl. J. Med.,
December 26, 1996;
335(26):
1933 - 1940.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. J. Fahy, E. B. Sgarbossa, P. J. Tchou, and S. L. Pinski
Hospital Readmission in Patients Treated With Tiered-Therapy Implantable Defibrillators
Circulation,
September 15, 1996;
94(6):
1350 - 1356.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
H. Rastegar, M. S. Link, C. B. Foote, P. J. Wang, A. S. Manolis, and N.A. M. Estes
Perioperative and Long-term Results With Mapping-Guided Subendocardial Resection and Left Ventricular Endoaneurysmorrhaphy
Circulation,
September 1, 1996;
94(5):
1041 - 1048.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. N. Cohn
The Management of Chronic Heart Failure
N. Engl. J. Med.,
August 15, 1996;
335(7):
490 - 498.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Bocker, W. Haverkamp, M. Block, M. Borggrefe, D. Hammel, and G. Breithardt
Comparison of d,l-Sotalol and Implantable Defibrillators for Treatment of Sustained Ventricular Tachycardia or Fibrillation in Patients With Coronary Artery Disease
Circulation,
July 15, 1996;
94(2):
151 - 157.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
E. U. Alt, P. C. Fotuhi, R. L. Callihan, E. Mestre, W. M. Smith, and R. E. Ideker
Endocardial Carbon-Braid Electrodes : A New Concept for Lower Defibrillation Thresholds
Circulation,
September 15, 1995;
92(6):
1627 - 1633.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation,
September 15, 1995;
92(6):
1651 - 1664.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
D. H. Mull, M. A. Wait, R. L. Page, and M. E. Jessen
Importance of Complete System Removal of Infected Cardioverter-Defibrillators
Ann. Thorac. Surg.,
September 1, 1995;
60(3):
704 - 706.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. E. Molina, D. G. Benditt, and S. Adler
Crinkling of epicardial defibrillator patchesA common and serious problem
J. Thorac. Cardiovasc. Surg.,
July 1, 1995;
110(1):
258 - 264.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
D. M. Shahian, W. A. Williamson, L. G. Svensson, R. S. D'Agostino, D. T. Martin, J. R. Ellis, and F. J. Venditti
Transvenous versus transthoracic cardioverter-defibrillator implantation: A comparative analysis of morbidity, mortality, and survival
J. Thorac. Cardiovasc. Surg.,
June 1, 1995;
109(6):
1066 - 1074.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. O. Nunain, M. Roelke, T. Trouton, S. Osswald, Y. H. Kim, G. Sosa-Suarez, D. R. Brooks, B. McGovern, M. Guy, D. F. Torchiana, et al.
Limitations and Late Complications of Third-Generation Automatic Cardioverter-Defibrillators
Circulation,
April 15, 1995;
91(8):
2204 - 2213.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
M. J. Reiter, D. E. Mann, J. E. Reiffel, E. Hahn, and V. Hartz
Significance and Incidence of Concordance of Drug Efficacy Predictions by Holter Monitoring and Electrophysiological Study in the ESVEM Trial
Circulation,
April 1, 1995;
91(7):
1988 - 1995.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
L.-A. M. Beauregard, P. W. Barnard, A. M. Russo, and H. L. Waxman
Perceived and Actual Risks of Driving in Patients With Arrhythmia Control Devices
Arch Intern Med,
March 27, 1995;
155(6):
609 - 613.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
R. S. Damle, F. A. Ehlert, S. L. Winters, D. Rubinstein, J. A. Gomes, J. W. Mason, and The ESVEM Investigators
The Treatment of Ventricular Tachyarrhythmias
N. Engl. J. Med.,
January 27, 1994;
330(4):
286 - 288.
[Full Text]
|
 |
|

|
 |

|
 |
 
T. J. Cohen, P. R. Reid, M. M. Mower, M. Mirowski, D. Aarons, J. Juanteguy, and E. P. Veltri
The Automatic Implantable Cardioverter-Defibrillator: Long-term Clinical Experience and Outcome at a Hospital Without an Open-Heart Surgery Program
Arch Intern Med,
January 1, 1992;
152(1):
65 - 69.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
S. A. Strickberger, C. O. Cantillon, and P. L. Friedman
When Should Patients with Lethal Ventricular Arrhythmia Resume Driving? An Analysis of State Regulations and Physician Practices
Ann Intern Med,
October 1, 1991;
115(7):
560 - 563.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J. M. Gore and J. E. Dalen
Cardiovascular Disease
JAMA,
June 19, 1991;
265(23):
3105 - 3107.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J. N. Weiss, K. Nademanee, W. G. Stevenson, and B. Singh
Ventricular Arrhythmias in Ischemic Heart Disease
Ann Intern Med,
May 1, 1991;
114(9):
784 - 797.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Akhtar, H. Garan, M. H. Lehmann, and P. J. Troup
Sudden Cardiac Death: Management of High-Risk Patients
Ann Intern Med,
March 15, 1991;
114(6):
499 - 512.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Brooks, B. A. McGovern, H. Garan, and J. N. Ruskin
Current Treatment of Patients Surviving Out-of-Hospital Cardiac Arrest
JAMA,
February 13, 1991;
265(6):
762 - 768.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. S. Manolis, H. Rastegar, and N. A. M. Estes III
Automatic Implantable Cardioverter Defibrillator: Current Status
JAMA,
September 8, 1989;
262(10):
1362 - 1368.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
IMPLANTABLE DEFIBRILLATOR EFFECTIVE IN PREVENTING SUDDEN DEATH
Journal Watch (General),
May 16, 1989;
1989(516):
4 - 4.
[Full Text]
|
 |
|
|