Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1989; 13:1309-1313
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, C.
Right arrow Articles by Lin, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, C.
Right arrow Articles by Lin, Y.

Reliability of the Doppler pressure half-time method for assessing effects of percutaneous mitral balloon valvuloplasty

CG Chen, YP Wang, BL Guo, and YS Lin

Cardiovascular Center, Fujian Medical College, Fuzhou, People's Republic of China.

The mitral valve areas determined by Doppler pressure half-time and by cardiac catheterization with use of the Gorlin formula were compared in 18 adult patients who underwent percutaneous mitral balloon valvuloplasty. Doppler measurements and catheterization were performed simultaneously before, immediately after and 24 to 48 h after valvuloplasty. A high correlation between Doppler- and catheterization-derived mitral valve areas was found before mitral valvuloplasty (r = 0.81, Y = 0.88X + 0.1, SEE = 0.11 cm2) and 24 to 48 h after valvuloplasty (r = 0.84, Y = 0.70X + 0.67, SEE = 0.20 cm2). In contrast, the correlation immediately after valvuloplasty was only moderate (r = 0.72, Y = 0.43X + 1.1, SEE = 0.49 cm2). The Doppler-derived mitral valve area (2.41 +/- 0.61 cm2) immediately after valvuloplasty was significantly larger than the catheterization-derived area (2.08 +/- 0.39 cm2, p less than 0.05). In conclusion, the Doppler echocardiographic measurement performed with the pressure half-time method may lead to significant error immediately after mitral balloon valvuloplasty, but clinically accurate measurement can be obtained 24 to 48 h after valvuloplasty.


This article has been cited by other articles:


Home page
ChestHome page
M.-C. Chen, C.-J. Wu, H.-W. Chang, H.-K. Yip, Y.-H. Chen, C.-I Cheng, and H.-T. Chai
Mechanism of Reducing Platelet Activity by Percutaneous Transluminal Mitral Valvuloplasty in Patients With Rheumatic Mitral Stenosis
Chest, May 1, 2004; 125(5): 1629 - 1634.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M.-C. Chen, C.-J. Wu, H.-K. Yip, H.-W. Chang, C.-Y. Fang, T.-H. Yu, and M. Fu
Left Atrial Platelet Activity With Rheumatic Mitral Stenosis: Correlation Study of Severity and Platelet P-Selectin Expression by Flow Cytometry
Chest, November 1, 2003; 124(5): 1663 - 1669.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
R. Taylor
Assessing Mitral Stenosis with Doppler Echocardiography: Limitations of the Pressure Half-Time Method
Journal of Diagnostic Medical Sonography, July 1, 1990; 6(4): 219 - 223.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement