Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1989; 13:1167-1175
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, B.
Right arrow Articles by Nardella, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, B.
Right arrow Articles by Nardella, P.

Thermal compression and molding of atherosclerotic vascular tissue with use of radiofrequency energy: implications for radiofrequency balloon angioplasty

BI Lee, GJ Becker, BF Waller, KJ Barry, RJ Connolly, J Kaplan, AR Shapiro, and PC Nardella

Division of Cardiology, Georgetown University School of Medicine, Washington, D.C.

The combined delivery of pressure and thermal energy may effectively remodel intraluminal atherosclerotic plaque and fuse intimal tears. To test these hypotheses with use of a non-laser thermal energy source, radiofrequency energy was delivered to postmortem human atherosclerotic vessels from a metal "hot-tip" catheter, block-mounted bipolar electrodes and from a prototype radiofrequency balloon catheter. Sixty-two radiofrequency doses delivered from a metal electrode tip produced dose-dependent ablation of atherosclerotic plaque, ranging from clean and shallow craters with histologic evidence of thermal compression at doses less than 40 J to tissue charring and vaporization at higher (greater than 80 J) doses. Lesion dimensions ranged between 3.14 and 3.79 mm in diameter and 0.20 and 0.47 mm in depth. Tissue perforation was not observed. To test the potential for radiofrequency fusion of intimal tears, 5 atm of pressure and 200 J radiofrequency energy were delivered from block-mounted bipolar electrodes to 48 segments of human atherosclerotic aorta, which had been manually separated into intima-media and media-adventitial layers. Significantly stronger tissue fusion resulted (28.5 +/- 3.3 g) with radiofrequency compared with that with pressure alone (4.8 +/- 0.26 g; p less than 0.0001). A prototype radiofrequency balloon catheter was used to deliver 3 atm of balloon pressure with or without 200 J radiofrequency energy to 20 postmortem human atherosclerotic arterial segments. In 10 of 10 radiofrequency-treated vessels, thermal "molding" of both normal and atherosclerotic vessel wall segments resulted with increased luminal diameter and histologic evidence of medial myocyte damage.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
K. Neya, R. Lee, J. L. Guerrero, P. Lang, and G. J. Vlahakes
Experimental Ablation of Outflow Tract Muscle With a Thermal Balloon Catheter
Circulation, May 1, 1995; 91(9): 2445 - 2453.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement