Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1989; 13:1094-1100
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nichols, A.
Right arrow Articles by Powers, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nichols, A.
Right arrow Articles by Powers, E.

Importance of balloon size in coronary angioplasty

AB Nichols, R Smith, AD Berke, RA Shlofmitz, and ER Powers

Department of Medicine, College of Physicians and Surgeons, Columbia University.

The effect of balloon size on the success of coronary angioplasty was studied to develop quantitative criteria for optimal selection of balloon size. Coronary dimensions of 165 stenotic lesions were measured by computer-assisted cinevideodensitometry in 120 patients who had undergone angioplasty with a balloon selected by visual estimates. Cross-sectional areas and diameters of normal and stenotic arterial segments were measured before and after angioplasty by a previously validated cinevideodensitometric technique. The diameter of the inflated balloon compared with that of the normal arterial segment was expressed as a ratio for sizing balloons. Oversized balloons with a ratio greater than 1.3 (n = 35) caused a high (37%) incidence of dissection, with three severely compromised arterial lumens. Undersized balloons with a ratio less than 0.9 (n = 29) often resulted in significant (greater than 50% diameter stenosis) residual stenotic lesions (21%) and a significantly (p less than 0.05) higher rate of repeat angioplasty for restenosis. Selection of balloon sizes with ratios in the 0.9 to 1.3 range (n = 101) resulted in a low (4%) incidence of dissection with few patients (3%) having significant residual stenosis. Mean residual stenosis (percent diameter reduction) was most severe for undersized (35.0 +/- 18%) or oversized (23.1 +/- 19%) balloons and least severe for balloons with a ratio of 0.9 to 1.3 (18.7 +/- 14%) (p less than 0.001). Repeat angioplasty for restenosis was more frequently required (p less than 0.05) for lesions dilated with undersized balloons. Thus, selection of angioplasty balloons that approximate or slightly exceed the diameter of the normal arterial diameter yields optimal angiographic results with minimal dissections and minimal residual stenotic lesions.


This article has been cited by other articles:


Home page
Eur Heart JHome page
M. Haude and R. Erbel
How big is small?
Eur. Heart J., February 1, 2002; 23(3): 198 - 199.
[Full Text] [PDF]


Home page
Eur Heart JHome page
C. Briguori, J. Tobis, T. Nishida, M. Vaghetti, R. Albiero, C. Di Mario, and A. Colombo
Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries
Eur. Heart J., February 1, 2002; 23(3): 247 - 254.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. A. M. van Liebergen, J. J. Piek, K. T. Koch, R. J. G. Peters, R. J. de Winter, C. E. Schotborgh, and K. I. Lie
Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation
J. Am. Coll. Cardiol., December 1, 1999; 34(7): 1899 - 1906.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. R. Narins, D. R. Holmes Jr, and E. J. Topol
A Call for Provisional Stenting : The Balloon Is Back!
Circulation, April 7, 1998; 97(13): 1298 - 1305.
[Full Text] [PDF]


Home page
CirculationHome page
G. W. Stone, J. M. Hodgson, F. G. St Goar, A. Frey, H. Mudra, H. Sheehan, and T. J. Linnemeier
Improved Procedural Results of Coronary Angioplasty With Intravascular Ultrasound–Guided Balloon Sizing : The CLOUT Pilot Trial
Circulation, April 15, 1997; 95(8): 2044 - 2052.
[Abstract] [Full Text]


Home page
NEJMHome page
C. Landau, R. A. Lange, and L. D. Hillis
Percutaneous Transluminal Coronary Angioplasty
N. Engl. J. Med., April 7, 1994; 330(14): 981 - 993.
[Full Text]


Home page
ANN INTERN MEDHome page
K. H. Sheikh, C. J. Davidson, G. E. Newman, K. B. Kisslo, and S. J. Schwab
Intravascular Ultrasound Assessment of the Renal Artery
Ann Intern Med, July 1, 1991; 115(1): 22 - 25.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement