Impaired coronary vasodilator reserve in the immediate postcoronary angioplasty period: analysis of coronary artery flow velocity indexes and regional cardiac venous efflux
MJ Kern,
U Deligonul,
M Vandormael,
A Labovitz,
CV Gudipati,
G Gabliani,
J Bodet,
Y Shah,
and
HL Kennedy
Department of Internal Medicine, St. Louis University Hospital, Missouri 63104.
The ratio of peak hyperemic/basal mean coronary flow velocity, an index of coronary vasodilator reserve, immediately after coronary angioplasty normalizes in less than 50% of patients. To evaluate other indexes of coronary vasodilator capacity, both intracoronary arterial velocity and cardiac venous efflux were measured at rest and during vasodilator-induced coronary hyperemia (intracoronary nitroglycerin and papaverine) before and after angioplasty in 27 patients; 17 patients had measurements of intracoronary velocity alone and 10 had thermodilution measurements of great cardiac vein flow. Coronary flow velocity responses were also measured in 6 angiographically normal segments in patients undergoing angioplasty and in 10 normal left coronary artery segments in patients with normal coronary arteries or isolated right coronary artery disease. Despite significant angiographic (72 +/- 12 to 23 +/- 11% diameter narrowing) and hemodynamic (49 +/- 12 to 19 +/- 12 mm Hg aortocoronary gradient) improvement, coronary vasodilator reserve ratios for both arterial velocity and venous flow after angioplasty were only minimally affected. Angioplasty did not significantly increase rest coronary vein flow or artery flow velocities, but did result in significantly higher papaverine responses after angioplasty. Mean and phasic coronary velocity, diastolic coronary flow velocity integral and measured great cardiac vein flow ratios were significantly lower when compared with those in 16 angiographically normal coronary artery segments. These data indicate that maximal hyperemic coronary flow velocity is increased after angioplasty, but the reserve ratios, calculated by any of several flow velocity indexes, remain minimally improved. Angiographic correlations (percent coronary diameter, absolute diameter or cross-sectional area) with variables of coronary blood flow or velocity suggest that no single variable is useful in assessing angioplasty results. However, postangioplasty arterial mean velocity and diastolic flow velocity integral are nearly normalized in most patients, whereas relative changes remain attenuated. These findings are important in studies assessing coronary vasomotor responses in patients with atherosclerotic coronary disease, especially after angioplasty.
This article has been cited by other articles:

|
 |

|
 |
 
M. Voskuil, R. A. M. van Liebergen, M. Albertal, E. Boersma, J. G. P. Tijssen, P. W. Serruys, J. J. Piek, and the DEBATE II Investigators
Coronary hemodynamics of stent implantation after suboptimal and optimal balloon angioplasty
J. Am. Coll. Cardiol.,
May 1, 2002;
39(9):
1513 - 1517.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Pizzuto, P. Voci, E. Mariano, P. Emilio Puddu, G. Sardella, and A. Nigri
Assessment of flow velocity reserve by transthoracic Doppler echocardiography and venous adenosine infusion before and after left anterior descending coronary artery stenting
J. Am. Coll. Cardiol.,
July 1, 2001;
38(1):
155 - 162.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. Al-Saadi, E. Nagel, M. Gross, B. Schnackenburg, I. Paetsch, C. Klein, and E. Fleck
Improvement of myocardial perfusion reserve early after coronary intervention: assessment with cardiac magnetic resonance imaging
J. Am. Coll. Cardiol.,
November 1, 2000;
36(5):
1557 - 1564.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. J. Kern
Coronary Physiology Revisited : Practical Insights From the Cardiac Catheterization Laboratory
Circulation,
March 21, 2000;
101(11):
1344 - 1351.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
I. Kosa, R. Blasini, J. Schneider-Eicke, T. Dickfeld, F. J. Neumann, S. Ziegler, I. Matsunari, J. Neverve, A. Schomig, and M. Schwaiger
Early recovery of coronary flow reserve after stent implantation as assessed by positron emission tomography
J. Am. Coll. Cardiol.,
October 1, 1999;
34(4):
1036 - 1041.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C J Vrints, M J Claeys, J Bosmans, V Conraads, and J P Snoeck
Effect of stenting on coronary flow velocity reserve: comparison of coil and tubular stents
Heart,
October 1, 1999;
82(4):
465 - 470.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. Gregorini, J. Marco, M. Kozakova, C. Palombo, G. B. Anguissola, I. Marco, M. Bernies, B. Cassagneau, A. Distante, I. M. Bossi, et al.
{alpha}-Adrenergic Blockade Improves Recovery of Myocardial Perfusion and Function After Coronary Stenting in Patients With Acute Myocardial Infarction
Circulation,
February 2, 1999;
99(4):
482 - 490.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. A. M. van Liebergen, J. J. Piek, K. T. Koch, R. J. de Winter, and K. I. Lie
Immediate and Long-Term Effect of Balloon Angioplasty or Stent Implantation on the Absolute and Relative Coronary Blood Flow Velocity Reserve
Circulation,
November 17, 1998;
98(20):
2133 - 2140.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Isaaz, A. da Costa, J. P. de Pasquale, A. Cerisier, and M. Lamaud
Use of the continuity equation for transesophageal Doppler assessment of severity of proximal left coronary artery stenosis: a quantitative coronary angiography validation study
J. Am. Coll. Cardiol.,
July 1, 1998;
32(1):
42 - 48.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. W. Serruys, C. di Mario, J. Piek, E. Schroeder, C. Vrints, P. Probst, B. de Bruyne, C. Hanet, E. Fleck, M. Haude, et al.
Prognostic Value of Intracoronary Flow Velocity and Diameter Stenosis in Assessing the Short- and Long-term Outcomes of Coronary Balloon Angioplasty : The DEBATE Study (Doppler Endpoints Balloon Angioplasty Trial Europe)
Circulation,
November 18, 1997;
96(10):
3369 - 3377.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
R. Altstidl, M. Regenfus, H. Lehmkuhl, H. Dill, K. Bachmann, and R. Altstidl
Evaluation of Successful PTCA by Transstenotic Flow Velocity Ratios
Angiology,
September 1, 1997;
48(9):
775 - 782.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Chauhan, C. D. Potter, P. A. Mullins, D. R. Wheeldon, M. C. Petch, and P. M. Schofield
Measurements of Human Coronary Vascular Impedance
Angiology,
December 1, 1994;
45(12):
991 - 996.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Dill, R. Altstidl, M. Regenfus, H. Lehmkuhl, and K. Bachmann
Doppler Flow Velocity Measurements During Coronary Angioplasty
Angiology,
October 1, 1994;
45(10):
877 - 882.
[Abstract]
[PDF]
|
 |
|
|