JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1989; 13:340-347
© 1989 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Looyenga, D.
Right arrow Articles by Messer, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Looyenga, D.
Right arrow Articles by Messer, J.

Determination of cardiac output in critically ill patients by dual beam Doppler echocardiography

DS Looyenga, PR Liebson, RC Bone, RA Balk, and JV Messer

Section of Cardiology, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois 60612-3864.

Recent technology in Doppler echocardiography has produced a dual beam Doppler instrument that is capable of insonating the total cross-sectional area of the ascending aorta. The purpose of this study was to evaluate the accuracy of this instrument in measuring cardiac output in critically ill patients by comparing results with those of the thermodilution-derived cardiac output. A technically adequate Doppler cardiac output measurement was attained in 71 (91%) of 78 patients. The range of thermodilution-derived cardiac output measurements was from 1.58 to 11.70 liters/min. To maximize thermodilution cardiac output reliability, several measurements were made for each patient. Those patients in whom the difference between the highest and lowest measurement varied by less than 10% from the averaged results were accepted into the 50 patient study. There was significant correlation between dual beam Doppler- and thermodilution-derived cardiac output (r = 0.96, SEE = 0.55 liters/min, p less than 0.0001). This study demonstrates that dual beam Doppler ultrasound is a promising noninvasive method of measuring cardiac output in the critically ill patient.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
T. Buck, B. Plicht, P. Hunold, R. A. Mucci, R. Erbel, and R. A. Levine
Broad-beam spectral Doppler sonification of the vena contracta using matrix-array technology: A new solution for semi-automated quantification of mitral regurgitant flow volume and orifice area
J. Am. Coll. Cardiol., March 1, 2005; 45(5): 770 - 779.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Buck, R. A. Mucci, J. L. Guerrero, G. Holmvang, M. D. Handschumacher, and R. A. Levine
The Power-Velocity Integral at the Vena Contracta : A New Method for Direct Quantification of Regurgitant Volume Flow
Circulation, August 29, 2000; 102(9): 1053 - 1061.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
T Iwao, K Oho, R Nakano, M Yamawaki, T Sakai, M Sato, Y Miyamoto, A Toyonaga, and K Tanikawa
Effect of meal induced splanchnic arterial vasodilatation on renal arterial haemodynamics in normal subjects and patients with cirrhosis
Gut, December 1, 1998; 43(6): 843 - 848.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1989 by the American College of Cardiology Foundation.