Fluid dynamics model of mitral valve flow: description with in vitro validation
JD Thomas
and
AE Weyman
Noninvasive Cardiac Laboratory, Massachusetts General Hospital, Boston 02114.
A lumped variable fluid dynamics model of mitral valve blood flow is described that is applicable to both Doppler echocardiography and invasive hemodynamic measurement. Given left atrial and ventricular compliance, initial pressures and mitral valve impedance, the model predicts the time course of mitral flow and atrial and ventricular pressure. The predictions of this mathematic formulation have been tested in an in vitro analog of the left heart in which mitral valve area and atrial and ventricular compliance can be accurately controlled. For the situation of constant chamber compliance, transmitral gradient is predicted to decay as a parabolic curve, and this has been confirmed in the in vitro model with r greater than 0.99 in all cases for a range of orifice area from 0.3 to 3.0 cm2, initial pressure gradient from 2.4 to 14.2 mm Hg and net chamber compliance from 16 to 29 cc/mm Hg. This mathematic formulation of transmitral flow should help to unify the Doppler echocardiographic and catheterization assessment of mitral stenosis and left ventricular diastolic dysfunction.
This article has been cited by other articles:

|
 |

|
 |
 
L. Waite, G. Veres, J. Fine, and G. Szabo
A Computer Model of Early Diastolic Filling through the Mitral Valve
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine,
March 1, 2011;
225(3):
255 - 267.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Baumgartner, J. Hung, J. Bermejo, J. B. Chambers, A. Evangelista, B. P. Griffin, B. Iung, C. M. Otto, P. A. Pellikka, and M. Quinones
Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
Eur Heart J Cardiovasc Imaging,
January 1, 2009;
10(1):
1 - 25.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. W. Bowman, P. A. Frihauf, and S. J. Kovacs
Time-varying effective mitral valve area: prediction and validation using cardiac MRI and Doppler echocardiography in normal subjects
Am J Physiol Heart Circ Physiol,
October 1, 2004;
287(4):
H1650 - H1657.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Szabo, D. Soans, A. Graf, C. J. Beller, L. Waite, and S. Hagl
A new computer model of mitral valve hemodynamics during ventricular filling
Eur J Cardiothorac Surg,
August 1, 2004;
26(2):
239 - 247.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. Schwammenthal, Z. Vered, O. Agranat, E. Kaplinsky, B. Rabinowitz, and M. S. Feinberg
Impact of Atrioventricular Compliance on Pulmonary Artery Pressure in Mitral Stenosis : An Exercise Echocardiographic Study
Circulation,
November 7, 2000;
102(19):
2378 - 2384.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Y HENEIN and D. G GIBSON
Normal long axis function
Heart,
February 1, 1999;
81(2):
111 - 113.
[Full Text]
|
 |
|

|
 |

|
 |
 
M. J. Garcia, J. D. Thomas, and A. L. Klein
New Doppler echocardiographic applications for the study of diastolic function
J. Am. Coll. Cardiol.,
October 1, 1998;
32(4):
865 - 875.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|