cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1988; 12:739-745
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chapman, P.
Right arrow Articles by Hoffmann, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chapman, P.
Right arrow Articles by Hoffmann, R.

Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs

PD Chapman, JW Vetter, JJ Souza, PJ Troup, JN Wetherbee, and RG Hoffmann

Medical College of Wisconsin, Department of Medicine 53226.

Pentobarbital-anesthetized dogs were studied to determine the relative efficacy of monophasic and biphasic truncated exponential shocks employing a nonthoracotomy internal defibrillation pathway that consisted of a right ventricular catheter electrode (cathode) and a subcutaneous chest wall patch electrode (anode). In part 1 of the experiments, six dogs (19.6 +/- 1.1 kg) were utilized. Monophasic pulses of 5, 7.5, 10 and 12.5 ms duration were compared with biphasic pulses of the same total duration. The biphasic pulses had an initial positive phase (P1) followed by a terminal negative phase (P2) with the initial voltage equal for each phase. For each biphasic total pulse width, five relative P1 versus P2 durations were tested (50 and 50%, 75 and 25%, 90 and 10%, 25 and 75%, 10 and 90%). Ventricular fibrillation was induced by alternating current and pulse configurations were tested randomly to determine the minimal voltage and energy for defibrillation (threshold). Biphasic shocks with P1 longer than P2 were associated with significantly lower (p less than 0.01) energy thresholds than were monophasic shocks. Additionally, there was no significant relation between pulse width and voltage or energy thresholds. In part 2 of the experiments, six dogs (20.2 +/- 1.6 kg) were studied. Monophasic shocks were compared with biphasic shocks with P1 versus P2 durations of 75 and 25% and 90 and 10% for total pulse widths of 7.5, 10 and 12.5 ms. Threshold determinations were performed as in part 1. Subsequently, five initial voltages clustered about threshold were randomly tested four times and dose-response curves constructed for each pulse configuration with the use of stepwise logistic regression. Biphasic shocks resulted in significantly lower energy (p less than 0.0001) and voltage (p less than 0.001) requirements than did monophasic shocks.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
EuropaceHome page
K. A. Mowrey, Y. Cheng, P. J. Tchou, and I. R. Efimov
Kinetics of defibrillation shock-induced response: design implications for the optimal defibrillation waveform
Europace, January 1, 2002; 4(1): 27 - 39.
[Full Text] [PDF]


Home page
CirculationHome page
S. Mittal, S. Ayati, K. M. Stein, D. Schwartzman, D. Cavlovich, P. J. Tchou, S. M. Markowitz, D. J. Slotwiner, M. A. Scheiner, and B. B. Lerman
Transthoracic Cardioversion of Atrial Fibrillation : Comparison of Rectilinear Biphasic Versus Damped Sine Wave Monophasic Shocks
Circulation, March 21, 2000; 101(11): 1282 - 1287.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Huang, B. H. KenKnight, D. L. Rollins, W. M. Smith, and R. E. Ideker
Ventricular Defibrillation With Triphasic Waveforms
Circulation, March 21, 2000; 101(11): 1324 - 1328.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Mittal, S. Ayati, K. M. Stein, B. P. Knight, F. Morady, D. Schwartzman, D. Cavlovich, E. V. Platia, H. Calkins, P. J. Tchou, et al.
Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation
J. Am. Coll. Cardiol., November 1, 1999; 34(5): 1595 - 1601.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. D. Swerdlow, W. Fan, and J. E. Brewer
Charge-Burping Theory Correctly Predicts Optimal Ratios of Phase Duration for Biphasic Defibrillation Waveforms
Circulation, November 1, 1996; 94(9): 2278 - 2284.
[Abstract] [Full Text]


Home page
CirculationHome page
Y. Yamanouchi, K. A. Mowrey, G. R. Nadzam, D. G. Hills, M. W. Kroll, J. E. Brewer, A. M. Donohoo, B. L. Wilkoff, and P. J. Tchou
Large Change in Voltage at Phase Reversal Improves Biphasic Defibrillation Thresholds: Parallel-Series Mode Switching
Circulation, October 1, 1996; 94(7): 1768 - 1773.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
J. S. Lawton, K. A. Ellenbogen, M. A. Wood, B. S. Stambler, J. A. Spratt, A. S. Wechsler, and R. J. Damiano Jr
Clinical Experience With Nonthoracotomy Cardioverter Defibrillators
Ann. Thorac. Surg., May 1, 1995; 59(5): 1092 - 1098.
[Abstract] [Full Text]



 
  cardiology careers collections past issues search home