cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1988; 12:686-691
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zijlstra, F
Right arrow Articles by Serruys, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zijlstra, F
Right arrow Articles by Serruys, P.

Which cineangiographically assessed anatomic variable correlates best with functional measurements of stenosis severity? A comparison of quantitative analysis of the coronary cineangiogram with measured coronary flow reserve and exercise/redistribution thallium-201 scintigraphy

F Zijlstra, P Fioretti, JH Reiber, and PW Serruys

Catheterization Laboratory, Thoraxcenter, Erasmus University, Rotterdam, The Netherlands.

The goal of this investigation was to establish which measured anatomic variable of stenotic coronary lesions correlates best with functional severity. Therefore, 38 patients with single vessel disease underwent coronary cineangiography and exercise/redistribution thallium-201 scintigraphy. The computer-based Cardiovascular Angiography Analysis System was used to determine the cross-sectional area at the site of obstruction (OA) and percent diameter stenosis (DS), and to calculate the pressure drop over the stenosis (PD) with use of fluid dynamic equations. Coronary flow reserve was measured radiographically. Myocardial perfusion defects on thallium scintigrams were analyzed quantitatively and by visual interpretation. The relations between coronary flow reserve (CFR) and the three anatomic variables were described by the following equations: 1) CFR = 4.6 - 0.053 DS, r = 0.82; SEE: 0.79, p less than 0.001. 2) CFR = 0.5 + 0.75 OA, r = 0.87; SEE: 0.68, p less than 0.001). 3 CFR = 3.6 - 1.5 log PD, r = 0.90; SEE: 0.62, p less than 0.001. The calculated pressure drop was highly predictive of the thallium scintigraphic results with a sensitivity of 94% and a specificity of 90%. The calculated pressure drop is a better anatomic variable for assessing the functional importance of a stenosis than is percent diameter stenosis or obstruction area. However, the 95% confidence limits of the relation between pressure drop and coronary flow reserve are wide, making the measurement of coronary flow reserve an indispensable addition to quantitative angiography, especially when determining the functional importance of moderately severe coronary artery lesions.


This article has been cited by other articles:


Home page
HeartHome page
H J Verberne, J J Piek, R A M van Liebergen, K T Koch, J M Schroeder-Tanka, and E A van Royen
Functional assessment of coronary artery stenosis by Doppler derived absolute and relative coronary blood flow velocity reserve in comparison with 99mTc MIBI SPECT
Heart, October 1, 1999; 82(4): 509 - 514.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. D. Beleslin, M. Ostojic, A. Djordjevic-Dikic, R. Babic, M. Nedeljkovic, G. Stankovic, S. Stojkovic, J. Marinkovic, I. Nedeljkovic, J. Stepanovic, et al.
Integrated evaluation of relation between coronary lesion features and stress echocardiography results: the importance of coronary lesion morphology
J. Am. Coll. Cardiol., March 1, 1999; 33(3): 717 - 726.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Ferrari, B.a. Schnell, G. S. Werner, and H. R. Figulla
Safety of deferring angioplasty in patients with normal coronary flow velocity reserve
J. Am. Coll. Cardiol., January 1, 1999; 33(1): 82 - 87.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
M.G. Niemeyer, A.F.M. Kuijper, J.G. Meeder, M.J.M. Cramer, A.J.M. Cleophas, E.E. van der Wall, and M. G. Niemeyer
Comparison of Thallium Scintigraphy and Positron Emission Tomography
Angiology, October 1, 1997; 48(10): 843 - 853.
[Abstract] [PDF]


Home page
CirculationHome page
L. I. Heller, C. Cates, J. Popma, L. I. Deckelbaum, J. D. Joye, S. T. Dahlberg, B. J. Villegas, A. Arnold, R. Kipperman, W. C. Grinstead, et al.
Intracoronary Doppler Assessment of Moderate Coronary Artery Disease : Comparison With 201Tl Imaging and Coronary Angiography
Circulation, July 15, 1997; 96(2): 484 - 490.
[Abstract] [Full Text]


Home page
CirculationHome page
D. D. Miller, T. J. Donohue, T. L. Wolford, M. J. Kern, S. R. Bergmann, C. M. Mechem, and J. J. Hartman
Assessment of Blood Flow Distal to Coronary Artery Stenoses: Correlations Between Myocardial Positron Emission Tomography and Poststenotic Intracoronary Doppler Flow Reserve
Circulation, November 15, 1996; 94(10): 2447 - 2454.
[Abstract] [Full Text]



 
  cardiology careers collections past issues search home