JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1988; 12:492-497
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sholler, G.
Right arrow Articles by Keane, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sholler, G.
Right arrow Articles by Keane, J.

Noninvasive estimation of the left ventricular pressure waveform throughout ejection in young patients with aortic stenosis

GF Sholler, SD Colan, SP Sanders, and JF Keane

Department of Cardiology, Children's Hospital, Boston, Massachusetts.

Validation of a totally noninvasive method for estimating instantaneous left ventricular pressure and constructing a pressure waveform throughout ejection in patients with aortic stenosis is reported. In 20 patients (aged 8.75 +/- 10 years) with congenital aortic stenosis (measured peak left ventricular pressure 120 to 260 mm Hg; transvalvular gradient 18 to 165 mm Hg), transaortic valve continuous wave Doppler ultrasound, indirect carotid pulse tracing, peripheral blood pressure and measured left ventricular pressure were recorded simultaneously at cardiac catheterization. Data were entered into a microcomputer using a digitizing tablet and the instantaneous Doppler gradient was calculated and added to instantaneous aortic pressure, derived from the time-corrected and calibrated carotid pulse tracing, to estimate instantaneous left ventricular pressure. Estimated left ventricular pressure waveforms reproduced measured left ventricular pressure closely. The mean error at peak left ventricular pressure was 0.2 +/- 4.8 mm Hg (r = 0.98, p = 0.001). The average error throughout ejection was 0.9 +/- 5.1 mm Hg. The error of estimated pressure was not related to age or the severity of aortic stenosis. The Doppler peak instantaneous gradient was observed to correlate closely (r = 0.97, p = 0.001) with peak to peak gradient. With this technique, the left ventricular pressure waveform throughout ejection can be accurately estimated noninvasively in patients with aortic stenosis. This methodology enables determination of mean, total and instantaneous systolic left ventricular pressure.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Z. B. Popovic, U. N. Khot, G. M. Novaro, F. Casas, N. L. Greenberg, M. J. Garcia, G. S. Francis, and J. D. Thomas
Effects of sodium nitroprusside in aortic stenosis associated with severe heart failure: pressure-volume loop analysis using a numerical model
Am J Physiol Heart Circ Physiol, January 1, 2005; 288(1): H416 - H423.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1988 by the American College of Cardiology Foundation.