|
|
||||||||||
|
J Am Coll Cardiol, 1988; 11:1278-1286 © 1988 by the American College of Cardiology Foundation |
Cardiac Unit, Massachusetts General Hospital, Boston 02114.
Ninety-four patients underwent surgery for automatic implantable cardioverter-defibrillator implantation. Ninety patients were discharged from the hospital with the device and were followed up for a mean period of 17 +/- 10 months. Forty-six patients experienced at least one discharge of the device under circumstances consistent with a malignant ventricular arrhythmia. One sudden death occurred. Complications included perioperative death (3 patients), post-operative ventricular tachycardia (12 patients) and atrial fibrillation (8 patients), perioperative myocardial infarction (1 patient) and device discharges for sinus tachycardia and supraventricular arrhythmias (17 patients). Six and 12 month survival rates by life table analysis were 98.7 and 95.4%, respectively. Thus, the automatic implantable cardioverter-defibrillator is a highly effective and relatively low risk treatment modality for patients with refractory life-threatening ventricular arrhythmias.
This article has been cited by other articles:
![]() |
L. B. Mitchell, E. A. Pineda, J. L. Titus, P. M. Bartosch, and D. G. Benditt Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation J. Am. Coll. Cardiol., April 17, 2002; 39(8): 1323 - 1328. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. R. Cartwright and L. L. Hill Anesthesia for Insertion of Implantable Cardioverter Defibdilators Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2000; 4(3): 180 - 186. [Abstract] [PDF] |
||||
![]() |
A. Katz, R. J. Sweeney, R. M. Gill, P. R. Reid, and E. N. Prystowsky Relation of Atrial Refractoriness to Upper and Lower Limits of Vulnerability for Atrial Fibrillation/Flutter Following Implantable Ventricular Defibrillator Shocks Circulation, September 7, 1999; 100(10): 1125 - 1130. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Cannom and E. N. Prystowsky Management of Ventricular Arrhythmias: Detection, Drugs, and Devices JAMA, January 13, 1999; 281(2): 172 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
J P Bourke, A Loaiza, G Parry, C Hilton, S Furniss, J Dark, and J Forty Role of orthotopic heart transplantation in the management of patients with recurrent ventricular tachyarrhythmias following myocardial infarction Heart, November 1, 1998; 80(5): 473 - 478. [Abstract] [Full Text] |
||||
![]() |
Y. Yamanouchi, K. A. Mowrey, M. J. Niebauer, P. J. Tchou, and B. L. Wilkoff Additional Lead Improves Defibrillation Efficacy With an Abdominal `Hot Can' Electrode System Circulation, December 16, 1997; 96(12): 4400 - 4407. [Abstract] [Full Text] |
||||
![]() |
K. J. Quan, J. H. Lee, O. Costantini, A. K. Konstantakos, H. K. Murrell, M. D. Carlson, J. A. Mackall, L. A. Biblo, and A. S. Geha Favorable Results of Implantable Cardioverter-Defibrillator Implantation in Patients Older Than 70 Years Ann. Thorac. Surg., December 1, 1997; 64(6): 1713 - 1717. [Abstract] [Full Text] |
||||
![]() |
J. P Bourke, D. Turkington, G. Thomas, J. M McComb, and M. Tynan Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators Heart, December 1, 1997; 78(6): 581 - 583. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-J. Trappe, P. Pfitzner, M. Achtelik, and H.-G. Fieguth Age dependent efficacy of implantable cardioverter-defibrillator treatment: observations in 450 patients over an 11 year period Heart, October 1, 1997; 78(4): 364 - 370. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Strickberger, K. C. Man, E. G. Daoud, R. Goyal, K. Brinkman, C. Hasse, F. Bogun, B. P. Knight, R. Weiss, M. Bahu, et al. A Prospective Evaluation of Catheter Ablation of Ventricular Tachycardia as Adjuvant Therapy in Patients With Coronary Artery Disease and an Implantable Cardioverter-Defibrillator Circulation, September 2, 1997; 96(5): 1525 - 1531. [Abstract] [Full Text] |
||||
![]() |
M. Nair, N. Saoudi, D. Kroiss, and B. Letac Automatic Arrhythmia Identification Using Analysis of the Atrioventricular Association: Application to a New Generation of Implantable Defibrillators Circulation, February 18, 1997; 95(4): 967 - 973. [Abstract] [Full Text] |
||||
![]() |
J. E. Molina Undertreatment and Overtreatment of Patients With Infected Antiarrhythmic Implantable Devices Ann. Thorac. Surg., February 1, 1997; 63(2): 504 - 509. [Abstract] [Full Text] |
||||
![]() |
G. Gioia, B. Bagheri, C. D. Gottlieb, D. S. Schwartzman, D. J. Callans, F. E. Marchlinski, J. Heo, and A. E. Iskandrian Prediction of Outcome of Patients With Life-Threatening Ventricular Arrhythmias Treated With Automatic Implantable Cardioverter-Defibrillators Using SPECT Perfusion Imaging Circulation, January 21, 1997; 95(2): 390 - 394. [Abstract] [Full Text] |
||||
![]() |
S. O'Nunain, I. Perez, M. Roelke, S. Osswald, B. A. McGovern, D. R. Brooks, D. F. Torchiana, G. J. Vlahakes, J. Ruskin, and H. Garan THE TREATMENT OF PATIENTS WITH INFECTED IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEMS J. Thorac. Cardiovasc. Surg., January 1, 1997; 113(1): 121 - 129. [Abstract] [Full Text] |
||||
![]() |
A. J. Moss, W. J. Hall, D. S. Cannom, J. P. Daubert, S. L. Higgins, H. Klein, J. H. Levine, S. Saksena, A. L. Waldo, D. Wilber, et al. Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular Arrhythmia N. Engl. J. Med., December 26, 1996; 335(26): 1933 - 1940. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. E. Epstein, W. M. Miles, D. G. Benditt, A. J. Camm, E. J. Darling, P. L. Friedman, A. Garson, J. C. Harvey, G. A. Kidwell, G. J. Klein, et al. Personal and Public Safety Issues Related to Arrhythmias That May Affect Consciousness: Implications for Regulation and Physician Recommendations: A Medical/Scientific Statement From the American Heart Association and the North American Society of Pacing and Electrophysiology Circulation, September 1, 1996; 94(5): 1147 - 1166. [Full Text] |
||||
![]() |
P. C. Fotuhi, R. E. Ideker, S. F. Idriss, R. L. Callihan, R. G. Walker, and E. U. Alt Influence of Epicardial Patches on Defibrillation Threshold With Nonthoracotomy Lead Configurations Circulation, November 15, 1995; 92(10): 3082 - 3088. [Abstract] [Full Text] |
||||
![]() |
S. L. Pinski and G. J. Fahy The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators Circulation, September 15, 1995; 92(6): 1651 - 1664. [Abstract] [Full Text] |
||||
![]() |
J. E. Molina, D. G. Benditt, and S. Adler Crinkling of epicardial defibrillator patchesA common and serious problem J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 258 - 264. [Abstract] [Full Text] |
||||
![]() |
D. M. Shahian, W. A. Williamson, L. G. Svensson, R. S. D'Agostino, D. T. Martin, J. R. Ellis, and F. J. Venditti Transvenous versus transthoracic cardioverter-defibrillator implantation: A comparative analysis of morbidity, mortality, and survival J. Thorac. Cardiovasc. Surg., June 1, 1995; 109(6): 1066 - 1074. [Abstract] [Full Text] |
||||
![]() |
S. O. Nunain, M. Roelke, T. Trouton, S. Osswald, Y. H. Kim, G. Sosa-Suarez, D. R. Brooks, B. McGovern, M. Guy, D. F. Torchiana, et al. Limitations and Late Complications of Third-Generation Automatic Cardioverter-Defibrillators Circulation, April 15, 1995; 91(8): 2204 - 2213. [Abstract] [Full Text] |
||||
![]() |
E. U. Alt, P. C. Fotuhi, R. L. Callihan, D. L. Rollins, E. Mestre, M. P. Combs, W. M. Smith, and R. E. Ideker Improved Defibrillation Threshold With a New Epicardial Carbon Electrode Compared With a Standard Epicardial Titanium Patch Circulation, January 15, 1995; 91(2): 445 - 450. [Abstract] [Full Text] |
||||
![]() |
A. Renzulli, A. D'Onofrio, B.E. Glenville, S. Naik, J.P. Bourke, J.M. McComb, R.W.F. Campbell, and C.J. Hilton Surgical Treatment of Postinfarct Ventricular Tachycardia--Seven Years of Experience Vascular and Endovascular Surgery, May 1, 1991; 25(4): 301 - 307. [Abstract] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |