JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1988; 11:1073-1077
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hansen, D.
Right arrow Articles by Ritchie, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hansen, D.
Right arrow Articles by Ritchie, J.

Rotational endarterectomy in normal canine coronary arteries: preliminary report

DD Hansen, DC Auth, M Hall, and JL Ritchie

Division of Cardiology, Seattle Veterans Administration Hospital, Washington 98108.

Endarterectomy was performed in vivo using a high speed rotating abrasive-tipped catheter device in 11 normal canine coronary arteries. The device is designed to remove atheromatous material from diseased arteries by the abrasive action of its rotating tip. It was operated percutaneously from a femoral approach using conventional angioplasty guiding equipment. The rotating device was advanced over a guide wire from just beyond the tip of the guide catheter into the distal vessel. Six arteries were harvested immediately after endarterectomy and five were left in place for 7 +/- 2.8 days; in the latter group, the animals were maintained on a regimen of aspirin, 325 mg/day. Angiography before and after treatment demonstrated vessel patency in all cases. Caliper-measured luminal diameters were not significantly changed after endarterectomy. Histologic examination of pressure-fixed vessels showed extensive intimal loss and 20 to 30% loss of the internal elastic lamina. Medial damage was superficial and never exceeded 40% of the total medial thickness. There were no vessel perforations. Results of histologic study of the myocardium supplied by the treated vessels were normal without evidence of distal embolization or infarction. It is concluded that a high speed rotating abrasive device can be safely operated percutaneously in normal coronary arteries and results in minimal vessel damage and continued patency at 7 +/- 2.8 days.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
K.-C. Koch, J. vom Dahl, E. Kleinhans, H. G. Klues, P. W. Radke, S. Ninnemann, G. Schulz, U. Buell, and P. Hanrath
Influence of a platelet GPIIb/IIIa receptor antagonist on myocardial hypoperfusion during rotational atherectomy as assessed by myocardial Tc-99m sestamibi scintigraphy
J. Am. Coll. Cardiol., March 15, 1999; 33(4): 998 - 1004.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. B. King III
Angioplasty From Bench to Bedside to Bench
Circulation, May 1, 1996; 93(9): 1621 - 1629.
[Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1988 by the American College of Cardiology Foundation.