JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1988; 11:815-820
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rey, C
Right arrow Articles by Dupuis, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rey, C
Right arrow Articles by Dupuis, C

Percutaneous transluminal balloon valvuloplasty of congenital pulmonary valve stenosis, with a special report on infants and neonates

C Rey, P Marache, C Francart, and C Dupuis

Department of Pediatric Cardiology, Hopital Cardiologique, Lille, France.

Fifty-six percutaneous transluminal balloon valvuloplasty procedures were performed in 51 patients suffering from congenital pulmonary valve stenosis. The patients ranged in age from 1 day to 60 years (mean 6.9 years); 21 were infants less than 1 year of age, including 8 neonates. The peak systolic pressure gradient was greater than 50 mm Hg (mean 81.5) in 47 cases, and less than 50 mm Hg (mean 34.6) in 9. Valvuloplasty enabled a reduction in the mean right ventricular peak systolic pressure from 93.1 to 51.6 mm Hg (p less than 0.001), the mean transvalvular gradient from 73.4 to 27.0 mm Hg (p less than 0.001) and the mean right ventricular pressure expressed as a percent of systemic pressure from 99.5 to 52.0% (p less than 0.001). In infants and neonates, the mean right ventricular pressure expressed as a percent of systemic pressure decreased from 117.3 to 64.4% (p less than 0.001). In 23 patients, follow-up cardiac catheterization at 1 to 17 months revealed a significant change in the right ventricular systolic pressure, which decreased from 54.0 to 46.7 mm Hg (p less than 0.05), and in the peak systolic pressure gradient, which decreased from 27.3 to 22.6 mm Hg (p less than 0.05). Valvuloplasty is an effective procedure in relieving pulmonary stenosis in patients of all ages, including neonates.


This article has been cited by other articles:


Home page
CirculationHome page
H. D. Allen, R. H. Beekman III, A. Garson Jr, Z. M. Hijazi, C. Mullins, M. P. O'Laughlin, and K. A. Taubert
Pediatric Therapeutic Cardiac Catheterization : A Statement for Healthcare Professionals From the Council on Cardiovascular Disease in the Young, American Heart Association
Circulation, February 17, 1998; 97(6): 609 - 625.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
T.-L. Jaing, B. Hwang, J.-H. Lu, K.-S. Hsieh, and C.C. L. Meng
Percutaneous Balloon Valvuloplasty in Severe Pulmonary Valvular Stenosis
Angiology, June 1, 1995; 46(6): 503 - 509.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
B. Hwang, L.-Y. Chen, J.-H. Lu, and C. C. L. Meng
A Quantitative Analysis of the Structure of Right Ventricle-Pulmonary Artery Junction for Balloon Pulmonary Valvuloplasty in Children
Angiology, May 1, 1995; 46(5): 383 - 391.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1988 by the American College of Cardiology Foundation.