J Am Coll Cardiol, 1988; 11:590-596
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jones, D.
Right arrow Articles by Sharma, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, D.
Right arrow Articles by Sharma, A.

Sequential pulse defibrillation in humans: orthogonal sequential pulse defibrillation with epicardial electrodes

DL Jones, GJ Klein, GM Guiraudon, and AD Sharma

Department of Medicine, University of Western Ontario, London, Canada.

A newly described sequential pulse technique, using four mesh electrodes positioned to approximate a true orthogonal system around the heart, was compared with a single pulse system using two of these same electrodes, which were located in positions that would be used for an automatic implantable defibrillator. The influence of electrode size was also assessed. The minimal energy necessary for defibrillation (defibrillation threshold) was determined intraoperatively in 21 volunteer patients undergoing accessory pathway ablation of Wolff-Parkinson-White syndrome. Ventricular fibrillation was induced with alternating current. Ten seconds after fibrillation onset defibrillation shocks were begun using either the single or the sequential pulse technique with stored voltage incremented until defibrillation was accomplished (defibrillation threshold). Selection of the use of a single or sequential pulse technique for the initial attempt was randomized. Defibrillation thresholds were determined in three groups of patients: 1) those with four small mesh electrodes (6 cm2), 2) those with two small and two large (13 cm2) mesh electrodes, and 3) those with four large mesh electrodes. In all cases, the average minimal energy needed for sequential pulse defibrillation was less than that required for single pulse defibrillation in the same patients with the same electrodes (four small, 24.8 +/- 24.7 J single versus 6.7 +/- 8.3 J sequential; two small plus two large, 11.4 +/- 15.0 J single versus 2.7 +/- 1.4 J sequential; four large, 8.1 +/- 5.3 J single versus 3.9 +/- 2.6 J sequential). Using the 6 cm2 electrodes for single pulse defibrillation energies delivered at greater than 45 J in two patients failed to defibrillate the heart.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
R. A. S. Cooper, V. J. Plumb, A. E. Epstein, G. N. Kay, and R. E. Ideker
Marked Reduction in Internal Atrial Defibrillation Thresholds With Dual-Current Pathways and Sequential Shocks in Humans
Circulation, June 30, 1998; 97(25): 2527 - 2535.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. S. Cooper, W. M. Smith, and R. E. Ideker
Internal Cardioversion of Atrial Fibrillation : Marked Reduction in Defibrillation Threshold With Dual Current Pathways
Circulation, October 21, 1997; 96(8): 2693 - 2700.