cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1988; 11:338-342
© 1988 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dittmann, H
Right arrow Articles by Seipel, L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dittmann, H
Right arrow Articles by Seipel, L

Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect

H Dittmann, R Jacksch, W Voelker, KR Karsch, and L Seipel

Medical Department III, University of Tuebingen, West Germany.

In previous experimental and pediatric studies, the ratio of pulmonary to systemic flow (Qp/Qs) was accurately estimated by Doppler echocardiography in various cardiac shunt lesions. The purpose of this study was to assess the accuracy of pulsed Doppler echocardiography in determining the magnitude of shunt flow in adult patients with an ostium secundum type atrial septal defect. In 32 patients with high quality echocardiograms and excellent Doppler signals, blood flow was measured in the right and left ventricular outflow tract by Doppler echocardiography. In 16 patients without heart disease, the correlation (r) between systemic (Qs) and pulmonary (Qp) blood flow was 0.96 (SEE = 0.417 liter/min, y = 1.05x - 0.21) and the mean Qp/Qs ratio was 1.01 +/- 0.09. In 16 patients with an atrial septal defect, the Qp/Qs ration measured by oximetry ranged from 1.34 to 4.61 and by pulsed Doppler echocardiography from 1.31 to 4.46 (p = NS). In these 16 patients, the correlation between the Qp/Qs ratio determined by oximetry and pulsed Doppler echocardiography was significant (r = 0.82, SEE = 0.54). In the total group of 32 patients, the correlation was stronger (r = 0.93, SEE = 0.37). Systematic differences between the invasive and noninvasive shunt calculations did not occur. Thus, in adult patients with an atrial septal defect of the secundum type and high quality echocardiograms, the magnitude of left to right shunt can be accurately assessed by pulsed Doppler echocardiography. In the absence of pulmonary hypertension, pulsed Doppler echocardiography provides precise information for the decision to undertake conservative or operative treatment.


This article has been cited by other articles:


Home page
HeartHome page
Y Ueda, T Hozumi, K Yoshida, H Watanabe, T Akasaka, T Takagi, A Yamamuro, S Homma, and J Yoshikawa
Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method
Heart, September 1, 2002; 88(3): 278 - 282.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. G. Hundley, H. F. Li, R. A. Lange, D. P. Pfeifer, B. M. Meshack, J. E. Willard, C. Landau, D. Willett, L. D. Hillis, and R. M. Peshock
Assessment of Left-to-Right Intracardiac Shunting by Velocity-Encoded, Phase-Difference Magnetic Resonance Imaging : A Comparison With Oximetric and Indicator Dilution Techniques
Circulation, June 15, 1995; 91(12): 2955 - 2960.
[Abstract] [Full Text]



 
  cardiology careers collections past issues search home