J Am Coll Cardiol, 1987; 10:1078-1084 © 1987 by the American College of Cardiology Foundation |
Department of Pediatrics, C.S. Mott Children's Hospital, University of Michigan, Ann Arbor 48109.
Twenty-six children, aged 5 weeks to 14.7 years, underwent percutaneous balloon angioplasty for a discrete native coarctation of the aorta. The procedure reduced the systolic coarctation gradient acutely in all children. The mean systolic gradient decreased by 75%, from 48.6 +/- 2.4 before to 12.3 +/- 1.9 mm Hg after angioplasty (p less than 0.001). Long-term results were evaluated in 14 children by follow-up catheterization 12 to 26 months (mean 15.3) after angioplasty. At follow-up, the residual gradient averaged 11.7 +/- 3.7 mm Hg (range -5 to 36) and had not changed from that measured immediately after angioplasty (p = 0.64). Compared with preangioplasty values, the systolic pressure in the ascending aorta had improved substantially at follow-up (116.0 +/- 3.2 versus 143.9 +/- 3.1 mm Hg, p less than 0.001). On the basis of follow-up data, two groups of children were identified: Group 1 consisted of nine children with a good result, defined as a residual gradient less than 20 mm Hg and no aneurysm; Group 2 consisted of five children with a poor result, four with a residual gradient greater than 20 mm Hg (range 25 to 36) and one with an aneurysm at the dilation site. There was no statistical difference between the two groups in age at angioplasty, balloon size, ratio of balloon to isthmus diameters, follow-up duration, heart rate or cardiac output. However, of the four children with a residual gradient greater than 20 mm Hg, two were the youngest in the study, and in two the aorta was inadvertently dilated with a balloon 4 to 5 mm smaller than the isthmus diameter.(ABSTRACT TRUNCATED AT 250 WORDS)
This article has been cited by other articles:
![]() |
A. C. Fiore, L. K. Fischer, T. Schwartz, S. Jureidini, I. Balfour, D. Carpenter, D. Demello, K. S. Virgo, D. G. Pennington, and R. G. Johnson Comparison of Angioplasty and Surgery for Neonatal Aortic Coarctation Ann. Thorac. Surg., November 1, 2005; 80(5): 1659 - 1665. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. G. Cowley, G. S. Orsmond, P. Feola, L. McQuillan, and R. E. Shaddy Long-Term, Randomized Comparison of Balloon Angioplasty and Surgery for Native Coarctation of the Aorta in Childhood Circulation, June 28, 2005; 111(25): 3453 - 3456. [Abstract] [Full Text] [PDF] |
||||
![]() |
D A Harrison, P R McLaughlin, C Lazzam, M Connelly, and L N Benson Endovascular stents in the management of coarctation of the aorta in the adolescent and adult: one year follow up Heart, May 1, 2001; 85(5): 561 - 566. [Abstract] [Full Text] |
||||
![]() |
G. S. Shirali, C. E. Cephus, M. A. Kuhn, K. K. Ogata, L. K. Vander Dussen, R. E. Chinnock, N. F. Mulla, J. K. Johnston, L. L. Bailey, S. R. Gundry, et al. Posttransplant recoarctation of the aorta: a twelve year experience J. Am. Coll. Cardiol., August 1, 1998; 32(2): 509 - 514. [Abstract] [Full Text] [PDF] |
||||
![]() |
P S Rao and B Waterman Relation of biophysical response of coarcted aortic segment to balloon dilatation with development of recoarctation following balloon angioplasty of native coarctation Heart, April 1, 1998; 79(4): 407 - 411. [Abstract] [Full Text] |
||||
![]() |
K. P WALSH Interventional cardiology Arch. Dis. Child., January 1, 1997; 76(1): 6 - 8. [Full Text] |
||||
![]() |
S. F. Kaine, E. O'Brian Smith, A. R. Mott, C. E. Mullins, and T. Geva Quantitative Echocardiographic Analysis of the Aortic Arch Predicts Outcome of Balloon Angioplasty of Native Coarctation of the Aorta Circulation, September 1, 1996; 94(5): 1056 - 1062. [Abstract] [Full Text] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |