Evaluation of left ventricular systolic and diastolic dysfunction during transient myocardial ischemia produced by angioplasty
AJ Labovitz,
MK Lewen,
M Kern,
M Vandormael,
U Deligonal,
and
HL Kennedy
Department of Internal Medicine, St. Louis University School of Medicine, Missouri.
Acute myocardial ischemia is known to cause impairment of both left ventricular systolic and diastolic function. To further investigate these changes as well as their relation to common clinical variables (electrocardiographic [ECG] changes and chest pain), 32 patients were evaluated with Doppler echocardiography during coronary angioplasty. Doppler indexes of left ventricular diastolic function included the ratios of peak early to late and peak early to mean diastolic velocities as well as the ratios of early to late and first third to total velocity integral (one-third filling fraction). All diastolic indexes showed significant impairment by 15 seconds after coronary occlusion (ratio peak early to late filling velocity: 1.11 versus 0.96, p less than 0.01; ratio peak early to mean filling velocity: 1.9 versus 1.7, p less than 0.01; ratio early to late velocity integral: 1.58 versus 1.25, p less than 0.01; one-third filling fraction: 41.2 versus 37.7, p less than 0.01). Left ventricular systolic function was evaluated during coronary occlusion both qualitatively, as assessed by the appearance of a new wall motion abnormality on two-dimensional echocardiography (mean 28.8 seconds), and quantitatively by measurement of systolic percent area change on the two-dimensional short-axis view as well as the Doppler echocardiographic stroke integral index. Systolic indexes did not show significant change until 30 seconds after balloon inflation (percent area change: 42.8 versus 29.2, p less than 0.01; stroke integral index: 11.04 versus 9.36, p less than 0.01). ECGs were performed at 15 second intervals.(ABSTRACT TRUNCATED AT 250 WORDS)
This article has been cited by other articles:

|
 |

|
 |
 
M. Remmelink, K. D. Sjauw, J. P.S. Henriques, M. M. Vis, R. J. van der Schaaf, K. T. Koch, J. G.P. Tijssen, R. J. de Winter, J. J. Piek, and J. Baan Jr
Acute left ventricular dynamic effects of primary percutaneous coronary intervention from occlusion to reperfusion.
J. Am. Coll. Cardiol.,
April 28, 2009;
53(17):
1498 - 1502.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B Norager, M Husic, J E Moller, A Bo Hansen, P A Pellikka, and K Egstrup
Changes in the Doppler myocardial performance index during dobutamine echocardiography: association with neurohormonal activation and prognosis after acute myocardial infarction
Heart,
August 1, 2006;
92(8):
1071 - 1076.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. S. Shanewise
How to Reliably Detect Ischemia in the Intensive Care Unit and Operating Room
Seminars in Cardiothoracic and Vascular Anesthesia,
March 1, 2006;
10(1):
101 - 109.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J.-H. Baumert, K. E. Hecker, M. Hein, M. Reyle-Hahn, N. A. Horn, and R. Rossaint
Effects of xenon anaesthesia on the circulatory response to hypoventilation
Br. J. Anaesth.,
August 1, 2005;
95(2):
166 - 171.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. Bein, J. Renner, D. Caliebe, J. Scholz, A. Paris, S. Fraund, W. Zaehle, and P. H. Tonner
Sevoflurane but Not Propofol Preserves Myocardial Function During Minimally Invasive Direct Coronary Artery Bypass Surgery
Anesth. Analg.,
March 1, 2005;
100(3):
610 - 616.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J Quiles, M A Garcia-Fernandez, P B Almeida, E Perez-David, J Bermejo, M Moreno, and P Avanzas
Portable spectral Doppler echocardiographic device: overcoming limitations
Heart,
September 1, 2003;
89(9):
1014 - 1018.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. D. Lambiase, R. J. Edwards, M. R. Cusack, C. A. Bucknall, S. R. Redwood, and M. S. Marber
Exercise-induced ischemia initiates the second window of protection in humans independent of collateral recruitment
J. Am. Coll. Cardiol.,
April 2, 2003;
41(7):
1174 - 1182.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A M Duncan, C A O'Sullivan, G S Carr-White, D G Gibson, and M Y Henein
Long axis electromechanics during dobutamine stress in patients with coronary artery disease and left ventricular dysfunction
Heart,
October 1, 2001;
86(4):
397 - 404.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
V. Mor-Avi, K. A. Collins, C. E. Korcarz, M. Shah, K. T. Spencer, and R. M. Lang
Detection of regional temporal abnormalities in left ventricular function during acute myocardial ischemia
Am J Physiol Heart Circ Physiol,
April 1, 2001;
280(4):
H1770 - H1781.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Cerisano, L. Bolognese, P. Buonamici, R. Valenti, N. Carrabba, E. V. Dovellini, P. D. Pucci, G. M. Santoro, and D. Antoniucci
Prognostic implications of restrictive left ventricular filling in reperfused anterior acute myocardial infarction
J. Am. Coll. Cardiol.,
March 1, 2001;
37(3):
793 - 799.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Cinca, A. Rodriguez-Sinovas, I. Anivarro, C. Moure, M. Tresanchez, and J. Soler-Soler
Neurally mediated depressor hemodynamic response induced by intracoronary catheter balloon inflation in pigs
Cardiovasc Res,
April 1, 2000;
46(1):
198 - 206.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. J. Garcia, N. G. Smedira, N. L. Greenberg, M. Main, M. S. Firstenberg, J. Odabashian, and J. D. Thomas
Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation
J. Am. Coll. Cardiol.,
January 1, 2000;
35(1):
201 - 208.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Tanaka, K. Mizushige, H. Masugata, H. Matsuo, and K. Mizushige
Prolongation of Left Atrial Augmentation After Handgrip Stress in Coronary Artery Disease: Observation Using Pulsed Doppler Flowmetry
Angiology,
April 1, 1999;
50(4):
299 - 308.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Billinger, M. Fleisch, F. R. Eberli, A. Garachemani, B. Meier, and C. Seiler
Is the development of myocardial tolerance to repeated ischemia in humans due to preconditioning or to collateral recruitment?
J. Am. Coll. Cardiol.,
March 15, 1999;
33(4):
1027 - 1035.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Cerisano, L. Bolognese, N. Carrabba, P. Buonamici, G. M. Santoro, D. Antoniucci, A. Santini, G. Moschi, and P. F. Fazzini
Doppler-Derived Mitral Deceleration Time : An Early Strong Predictor of Left Ventricular Remodeling After Reperfused Anterior Acute Myocardial Infarction
Circulation,
January 19, 1999;
99(2):
230 - 236.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Tomai, F. Crea, A. Gaspardone, F. Versaci, A. S. Ghini, R. De Paulis, L. Chiariello, and P. A. Gioffre
Phentolamine Prevents Adaptation to Ischemia During Coronary Angioplasty : Role of {alpha}-Adrenergic Receptors in Ischemic Preconditioning
Circulation,
October 7, 1997;
96(7):
2171 - 2177.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
K. Mizushige, H. Masugata, H. Morita, S. Senda, H. Matsuo, and K. Mizushige
Left Ventricular Diastolic Filling Dynamics During Isometric Exertion in Syndrome X Assessed with Doppler Flowmetry
Angiology,
October 1, 1997;
48(10):
871 - 881.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. A. Leesar, M. Stoddard, M. Ahmed, J. Broadbent, and R. Bolli
Preconditioning of Human Myocardium With Adenosine During Coronary Angioplasty
Circulation,
June 3, 1997;
95(11):
2500 - 2507.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
P. Spirito and B. J. Maron
Doppler Echocardiography for Assessing Left Ventricular Diastolic Function
Ann Intern Med,
July 15, 1988;
109(2):
122 - 126.
[Abstract]
[PDF]
|
 |
|
|