JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1987; 10:655-661
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Geschwind, H.
Right arrow Articles by Kennedy, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Geschwind, H.
Right arrow Articles by Kennedy, H.

Efficiency and safety of optically modified fiber tips for laser angioplasty

HJ Geschwind, MJ Kern, MG Vandormael, JD Blair, U Deligonul, and HL Kennedy

To evaluate the safety and efficiency of optically modified fiber tips, craters were created in human cadaver atherosclerotic arterial walls using sapphire contact probes and lensed fibers connected to a continuous wave neodymium yttrium aluminum garnet (Nd-YAG) laser. Laser energy was emitted at a constant level of 50 J. The sapphire contact probe catheter consisted of a round 2.2 mm diameter synthetic sapphire attached to an 8F catheter into which a 0.2 mm diameter optical fiber was inserted with the distal tip maintained at 3 mm from the sapphire. The lensed fiber catheter consisted of a 0.2 mm optical fiber at the end of which a 1 mm diameter lens was made. The fiber was inserted into a 5F low profile balloon catheter with the lens maintained 3 mm beyond the catheter tip. During laser emissions the catheter tips were maintained in a stationary position in contact with tissue targets immersed in blood at an angle of 90 degrees. The diameter of holes at the entry and exit of craters, the depth of craters and thermal injury to adjacent tissue (rim of carbonization and vacuolization) were measured with microscopy. The volume of tissue removed was derived from these values. Controlled effect index was determined as the ratio of diameter of holes and the extent of thermal injury. Efficiency was determined as the ratio of volume of tissue removed and the energy required to vaporize tissue.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
VASC ENDOVASCULAR SURGHome page
H. F. Odink
Long-Term Follow-up of Laser-Assisted Angioplasty: Analysis of Factors Influencing Restenosis and Patency
Vascular and Endovascular Surgery, April 1, 1993; 27(3): 165 - 171.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
T. Tomaru, G. S. Abela, J. Gonzalez, P. Giacomino, S. E. Friedl, and G. R. Barbeau
Laser Recanalization of Thrombosed Arteries Using Thermal and/or Modified Optical Probes; Angiographic and Angioscopic Study
Angiology, May 1, 1992; 43(5): 412 - 420.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
S. R. Mohan, R.J. Hawker, A.P. Wolinski, J.A. Dunham, R.P. Grimley, and R. Downing
Platelet Accumulation After Laser Angioplasty A Scintigraphic Assessment
Angiology, January 1, 1992; 43(1): 11 - 21.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
H. Weber, S. Enders, and S. Hessel
Thermal Effects and Histologic Changes from Nd:YAG Laser Irradiation on Normal and Diseased Aortic Tissue Using a Novel Angioplasty Catheter with a Mobile Optical Fiber: An in Vitro Assessment
Angiology, August 1, 1991; 42(8): 597 - 606.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1987 by the American College of Cardiology Foundation.