Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter-defibrillator
I Singer,
GM Hutchins,
M Mirowski,
MM Mower,
EP Veltri,
T Guarnieri,
LS Griffith,
L Watkins,
J Juanteguy,
S Fisher,
et al.
The purpose of the present study was to examine at autopsy the effect of multiple defibrillations on the myocardium and the pathologic consequences of short- and long-term placement of the intravascular and interpericardial leads of the automatic implantable cardioverter-defibrillator. Twenty-five patients were examined at autopsy; 8 of them underwent lead implantation only and 17 received both leads and the automatic implantable cardioverter-defibrillator. Twelve patients (48%) died of ventricular tachycardia or ventricular fibrillation; seven (28%) died of other causes. Acute pericarditis occurred in all patients, resulting in a localized, progressive fibrosis around the apical patch lead without giving rise to pericardial restriction. Thrombus formation was associated with the superior vena cava spring electrode in four patients (17%) and the right ventricular rate-sensing electrode in one patient (4%). Asymptomatic pulmonary emboli occurred in two patients (8%). In one patient who underwent defibrillation 59 times, superior vena cava changes consisted of vein wall destruction, fibrosis and thrombus formation. Pathologic changes under the apical patch related to defibrillation were observed in seven patients; two of these had fewer than 5 defibrillations, one had 8 defibrillations and four had 21 to 74 defibrillations. These changes consisted of contraction band necrosis in four patients, vacuolar cytoplasmic clearing and loss of myocytes confined to the myocardium under the patch electrode in five patients who had multiple defibrillations. The observed pathologic changes were estimated to affect less than 2% of the total myocardial mass. Thus, the automatic implantable cardioverter-defibrillator lead system and multiple defibrillations result in localized myocardial injury confined to the tissue under the patch electrode.(ABSTRACT TRUNCATED AT 250 WORDS)
This article has been cited by other articles:

|
 |

|
 |
 
A. Kolodzinska, A. Kutarski, L. Koperski, M. Grabowski, B. Malecka, and G. Opolski
Differences in encapsulating lead tissue in patients who underwent transvenous lead removal
Europace,
January 13, 2012;
(2012)
eur384v1.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. Dvorak, M. Novak, P. Kamaryt, B. Slana, J. Lipoldova, and P. Dvorak
Histological findings around electrodes in pacemaker and implantable cardioverter-defibrillator patients: comparison of steroid-eluting and non-steroid-eluting electrodes
Europace,
January 1, 2012;
14(1):
117 - 123.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Novak, P. Dvorak, P. Kamaryt, B. Slana, and J. Lipoldova
Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes
Europace,
November 1, 2009;
11(11):
1510 - 1516.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Cevik, A. Perez-Verdia, and K. Nugent
Implantable cardioverter defibrillators and their role in heart failure progression
Europace,
June 1, 2009;
11(6):
710 - 715.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. A. Gatzoulis, G. K. Andrikopoulos, T. Apostolopoulos, E. Sotiropoulos, G. Zervopoulos, J. Antoniou, S. Brili, and C. I. Stefanadis
Electrical storm is an independent predictor of adverse long-term outcome in the era of implantable defibrillator therapy
Europace,
January 1, 2005;
7(2):
184 - 192.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. Lickfett, A. Bitzen, A. Arepally, K. Nasir, C. Wolpert, K.-M. Jeong, U. Krause, R. Schimpf, T. Lewalter, H. Calkins, et al.
Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement
Europace,
January 1, 2004;
6(1):
25 - 31.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. B. Mitchell, E. A. Pineda, J. L. Titus, P. M. Bartosch, and D. G. Benditt
Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation
J. Am. Coll. Cardiol.,
April 17, 2002;
39(8):
1323 - 1328.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. E. Epstein, G. N. Kay, V. J. Plumb, S. M. Dailey, and P. G. Anderson
Gross and Microscopic Pathological Changes Associated With Nonthoracotomy Implantable Defibrillator Leads
Circulation,
October 13, 1998;
98(15):
1517 - 1524.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
W. W. Barrington, U. Deligonul, A. R. Easley, and J. R. Windle
Defibrillator patch electrode constriction: An underrecognized entity
Ann. Thorac. Surg.,
October 1, 1995;
60(4):
1112 - 1116.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
G. F. O. Tyers
Reply
Ann. Thorac. Surg.,
March 1, 1989;
47(3):
485 - 485.
[PDF]
|
 |
|
|