JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1987; 10:150-155
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, M
Right arrow Articles by Fuster, V
Right arrow Search for Related Content
PubMed
Right arrow Articles by Cohen, M
Right arrow Articles by Fuster, V

Comparison of single plane videodensitometry-based right ventricular ejection fraction in right and left anterior oblique views to biplane geometry-based right ventricular ejection fraction

M Cohen, C Monsen, X Francis, W Sherman, JA Ambrose, LE Teichholz, and V Fuster

To evaluate the reliability of the videodensitometric assessment of right ventricular ejection fraction, 38 patients were studied during diagnostic cardiac catheterization. Digital subtraction images of the right ventricle were obtained in both the right anterior oblique and the left anterior oblique views, using direct intraventricular injection of dilute contrast medium. From the end-diastolic and end-systolic images obtained in each view, analysis of the relative brightness values generated a videodensitometry-based right ventricular ejection fraction for both the right and the left anterior oblique views. These values were compared with those generated by applying the geometry-based Simpson's rule to the orthogonal images. Right ventricular ejection fraction ranged from 22 to 88%. Videodensitometric ejection fraction in the right anterior oblique view correlated well with that in the left anterior oblique view (r = 0.88) and each correlated well with geometry-based ejection fraction (r = 0.91 and 0.82, respectively). In a subset of 18 patients without significant cardiac disease, mean videodensitometric right ventricular ejection fraction was 68% (versus 61% in the abnormal subset), and it correlated closely with left ventricular ejection fraction (r = 0.82). Videodensitometric analysis of digital subtraction images provides a reliable method for calculating right ventricular ejection fraction that is independent of geometry and reliably separates normal from abnormal values. Application of videodensitometric techniques should simplify analysis of the response of the right ventricle to different interventions in patients with cardiac disease.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1987 by the American College of Cardiology Foundation.