|
|
||||||||||
|
J Am Coll Cardiol, 1983; 1:1493-1502 © 1983 by the American College of Cardiology Foundation |
An association among premature ventricular complexes on routine electrocardiogram, elevated right ventricular systolic pressure and sudden death after repair of tetralogy of Fallot was previously reported. To examine this relation further, noninvasive, hemodynamic and invasive electrophysiologic data were studied in 27 patients who had undergone repair of tetralogy of Fallot 7 months to 21 years (mean 1.75 years) previously. Syncope, which had occurred in four patients, was not significantly related to ventricular arrhythmia on rest electrocardiogram, 24 hour electrocardiogram or treadmill test. All four patients with syncope had either nonsustained (two patients) or sustained (two patients) ventricular tachycardia induced at electrophysiologic study. His bundle to ventricle conduction interval was prolonged in two patients and Q to right ventricular apex interval was prolonged in three of the four patients. All four had abnormal anatomic or hemodynamic findings: two had a right ventricular systolic pressure of 70 mm Hg or more, one had right ventricular dysfunction with tricuspid insufficiency and one a septal aneurysm. The 9 patients with induced nonsustained or sustained ventricular tachycardia were then compared with the 15 patients without induced ventricular arrhythmias. Those with ventricular tachycardia had a greater prevalence of: more complex ventricular arrhythmia on 24 hour electrocardiogram (63 versus 0%, p less than 0.001), long His bundle to ventricle interval (44 versus 0%, p less than 0.001), right ventricular systolic pressure of 70 mm Hg or more (56 versus 0%, p less than 0.01) and reduced right ventricular ejection fraction (33 versus 7%, p less than 0.025). It is concluded that: 1) induction of nonsustained or sustained ventricular tachycardia was associated with a history of syncope; 2) all patients at risk for syncope could not be identified by routine electrocardiogram 24 hour electrocardiogram or treadmill test; 3) hemodynamic alterations may interact with intraventricular conduction abnormalities and predispose to ventricular tachycardia.
This article has been cited by other articles:
![]() |
G. F. Van Hare Substrate Mapping and Catheter Ablation of Ventricular Tachycardia after Right Ventriculotomy Circulation, November 13, 2007; 116(20): 2236 - 2237. [Full Text] [PDF] |
||||
![]() |
E. P. Walsh and F. Cecchin Arrhythmias in Adult Patients With Congenital Heart Disease Circulation, January 30, 2007; 115(4): 534 - 545. [Full Text] [PDF] |
||||
![]() |
I. Zeltser, J. W. Gaynor, M. Petko, R. J. Myung, M. Birbach, R. Waibel, R. F. Ittenbach, R. E. Tanel, V. L. Vetter, and L. A. Rhodes The roles of chronic pressure and volume overload states in induction of arrhythmias: An animal model of physiologic sequelae after repair of tetralogy of Fallot J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1542 - 1548. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Khairy, M. J. Landzberg, M. A. Gatzoulis, H. Lucron, J. Lambert, F. Marcon, M. E. Alexander, and E. P. Walsh Value of Programmed Ventricular Stimulation After Tetralogy of Fallot Repair: A Multicenter Study Circulation, April 27, 2004; 109(16): 1994 - 2000. [Abstract] [Full Text] [PDF] |
||||
![]() |
W A Helbing, A A W Roest, R A Niezen, H W Vliegen, M G Hazekamp, J Ottenkamp, A de Roos, and E E van der Wall ECG predictors of ventricular arrhythmias and biventricular size and wall mass in tetralogy of Fallot with pulmonary regurgitation Heart, December 1, 2002; 88(5): 515 - 519. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Gatzoulis, J. A. Till, J. Somerville, and A. N. Redington Mechanoelectrical Interaction in Tetralogy of Fallot : QRS Prolongation Relates to Right Ventricular Size and Predicts Malignant Ventricular Arrhythmias and Sudden Death Circulation, July 15, 1995; 92(2): 231 - 237. [Abstract] [Full Text] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |