JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1983; 1:1423-1434
© 1983 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, W.
Right arrow Articles by Wallace, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, W.
Right arrow Articles by Wallace, A.

Localization of septal pacing sites in the dog heart by epicardial mapping

WM Smith, RE Ideker, WM Smith, J Kasell, L Harrison, GH Bardy, JJ Gallagher, and AG Wallace

To examine whether different septal pacing sites could be distinguished by their epicardial activation patterns, six to eight stimulating electrodes were placed throughout the septum in seven open chest dogs. Unipolar electrograms were obtained from 52 epicardial electrodes during pacing from each stimulating electrode and isochronous epicardial maps were constructed. The location of each stimulating electrode was found by dissection, and its distance from the overlying epicardium was measured. To allow comparison among epicardial maps, the septum was conceptually subdivided into nine regions to which stimulating electrodes were assigned. Epicardial activation patterns from the same region were similar and these patterns allowed the region containing a stimulating electrode to be identified in many cases. Three other variables were found to have additional localizing value. There were: 1) the time from the stimulus to epicardial breakthrough, 2) the duration of epicardial activation, and 3) the area of epicardium activated in the first 5 ms after epicardial breakthrough. For those stimulating electrodes that could not be localized by their epicardial activation patterns, the distance of the stimulating electrode beneath the epicardium was well fit from these three variables by multiple regression (correlation coefficient [r] = 0.97). Thus, using all the previous factors, localization of septal pacing sites was possible in the noninfarcted dog heart by epicardial mapping.


This article has been cited by other articles:


Home page
Cardiovasc ResHome page
K. Derakhchan, R. Cardinal, S. Brunet, D. Klug, C. Pharand, T. Kus, and B. I. Sasyniuk
Polymorphic ventricular tachycardias induced by D-sotalol and phenylephrine in canine preparations of atrioventricular block: initiation in the conduction system followed by spatially unstable re-entry
Cardiovasc Res, June 1, 1998; 38(3): 617 - 630.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Kawamura, P. L. Page, R. Cardinal, P. Savard, and R. Nadeau
MAPPING OF SEPTAL VENTRICULAR TACHYCARDIA: CLINICAL AND EXPERIMENTAL CORRELATIONS
J. Thorac. Cardiovasc. Surg., October 1, 1996; 112(4): 914 - 925.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1983 by the American College of Cardiology Foundation.