Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1983; 1:339-354
© 1983 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parsonnet, V
Right arrow Articles by Bernstein, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parsonnet, V
Right arrow Articles by Bernstein, A.

Cardiac pacing in the 1980s: treatment and techniques in transition

V Parsonnet and AD Bernstein

The pacemaker of the 1980s is designed to maintain atrioventricular synchrony through dual-chamber pacing. This pacemaker is multiprogrammable and capable of telemetric transmission of biologic, electronic and electrophysiologic data. Several developments have made this therapeutic modality possible: 1) the cumulative survival rate of many lithium-battery pacemakers exceeds 95% at 5 years; 2) lead and connector problems are rare; 3) atrial and ventricular electrode malfunctions occur in less than 2% of implants; and 4) new introducer techniques have simplified implantation (mortality and major morbidity rates are 0.5 and 0.4%, respectively). With multiprogrammability, pacemaker function can be optimized for the patient's needs, and about 20% of reoperations can be avoided. Ninety-six dual-chamber (DDD) pacemakers, 55 of which have been followed up for more than 3 months, have provided trouble-free performance and have yielded salutary clinical results, particularly when implanted to replace previous ventricular inhibited units. Problems with these pacemakers have included unusual pacing electrocardiograms, pacemaker eccentricities, programmer maintenance, pacing and follow-up complexities and costs. In the 1980s, effort will be required to find a balance between rapidly evolving technology and the clinical need for complex pacing systems. From 1978 to 1981, the rate of pacemaker implantation grew from 309 to 513 implants per million population per year, and there are now approximately 500,000 patients with implanted pacemakers living in the United States. Indications for pacing are ill-defined, because in many cases the assessment of clinical response to pacing is largely subjective, lacking satisfactory quantitative indexes. This decade will be a time of reappraisal of the extent of clinical applicability of new techniques, particularly the multiprogrammable dual-chamber system which, after 3 years of clinical trial, shows promise of being the predominant pacemaker of the immediate future.


This article has been cited by other articles:


Home page
EuropaceHome page
C. C. de Cock, M. C. Giudici, and J. W. Twisk
Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing: A quantitative review
Europace, January 1, 2003; 5(3): 275 - 278.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Jeffrey and V. Parsonnet
Cardiac Pacing, 1960 1985 : A Quarter Century of Medical and Industrial Innovation
Circulation, May 19, 1998; 97(19): 1978 - 1991.
[Full Text] [PDF]


Home page
ANN INTERN MEDHome page
K. A. EAGLE, A. G. MULLEY, D. E. SINGER, D. SCHOENFELD, J. W. HARTHORNE, and G. E. THIBAULT
Single-Chamber and Dual-Chamber Cardiac Pacemakers: A Formal Cost Comparison
Ann Intern Med, August 1, 1986; 105(2): 264 - 271.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
B. Shively and N. Goldschlager
Progress in Cardiac Pacing: Part II
Arch Intern Med, December 1, 1985; 145(12): 2238 - 2244.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
B. Shively and N. Goldschlager
Progress in Cardiac Pacing: Part I
Arch Intern Med, November 1, 1985; 145(11): 2103 - 2106.
[Abstract] [PDF]


Home page
JAMAHome page
S. Bhatia and N. Goldschlager
Office Evaluation of the Pacemaker Patient: Detection of Normal and Abnormal Pacemaker Function
JAMA, September 13, 1985; 254(10): 1346 - 1352.
[Abstract] [PDF]


Home page
ANN INTERN MEDHome page
K. AUSUBEL and S. FURMAN
The Pacemaker Syndrome
Ann Intern Med, September 1, 1985; 103(3): 420 - 429.
[Abstract] [PDF]


Home page
ANN INTERN MEDHome page
R. M. LUCERI, A. CASTELLANOS, L. ZAMAN, and R. J. MYERBURG
The Arrhythmias of Dual-Chamber Cardiac Pacemakers and Their Management
Ann Intern Med, September 1, 1983; 99(3): 354 - 359.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement