Figure 4 Entrainment from the isthmus exit. (A) Electrocardiogram recorded during entrainment from the isthmus exit at 10 ms and 40 ms below the flutter cycle length (FCL10 and FCL40) compared to the non-paced flutter wave. At both FCL10 and FCL40 the paced flutter wave appears identical to the non-paced flutter wave and was recorded as concealed by three blinded observers on both occasions. (B) Intracardiac electrogram recording during entrainment at FCL40 ms from the isthmus exit (TA 1/2). The PPI minus FCL is 5 ms, confirming that this site is within the circuit. The upward arrows indicate the orthodromic activation time from TA 19/20 to TA 3/4 (80 ms), which is unchanged during entrainment consistent with orthodromic capture of TA 3/4. Allowing for the pacing spike artifact, there is no electrogram morphology change in TA 3/4 either.