0
Back To Top Jump Location
Sign In  | Cart
Left Shadow
Right Shadow
Clinical research: electrophysiology |

Implantable Cardioverter-Defibrillators in patients with arrhythmogenic right ventricular Dysplasia/Cardiomyopathy FREE

Ariel Roguin, MD, PhD; Chandra S Bomma, MD; Khurram Nasir, MD, MPH; Harikrishna Tandri, MRCP; Crystal Tichnell, MGC; Cynthia James, PhD; Julie Rutberg, BS; Jane Crosson, MD; Philip J Spevak, MD, FACC; Ronald D Berger, PhD, MD, FACC; Henry R Halperin, MA, MD; Hugh Calkins, MD, FACC
[+] Author Information

The Johns Hopkins arrhythmogenic right ventricular dysplasia program is funded by a private grant from the Bogle Foundation. This study is also supported by National Institutes of Health Research Grant 1 UO1 HL65594-01A1. Dr. Roguin is supported by the Israel Pacing Foundation, an Israel Medical Association Ami Cohen Grant, the Israel Heart Society, and an American Physician Fellowship Grant.Reprint requests and correspondence: Dr. Hugh Calkins, Director of the Arrhythmia Service and Clinical Electrophysiology Laboratory, Johns Hopkins Hospital, Carnegie 592, 600 North Wolfe Street, Baltimore, Maryland 21287-0409, USA.

American College of Cardiology Foundation

J Am Coll Cardiol. 2004;43(10):1843-1852. doi:10.1016/j.jacc.2004.01.030
Published online

Objectives  The aim of this study was to assess the outcome of arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) patients treated with an implantable cardioverter-defibrillator (ICD).

Background  Arrhythmogenic right ventricular dysplasia/cardiomyopathy is associated with tachyarrhythmia and an increased risk of sudden death.

Methods  This study included 42 ARVD/C patients with ICDs (52% male, age 6 to 69 years, median 37 years) followed at our center.

Results  Mean follow-up was 42 ± 26 months (range 4 to 135 months). Complications associated with ICD implantation included need for lead repositioning (n = 3) and system infection (n = 2). During follow-up, one patient died of a brain malignancy and one had heart transplantation. Lead replacement was required in six patients as a result of lead fracture and insulation damage (n = 4) or change in thresholds (n = 2). During this period, 33 of 42 (78%) patients received a median of 4 (range 1 to 75) appropriate ICD interventions. The median period between ICD implantation and the first firing was 9 months (range 0.1 to 66 months). The ICD firing storms were observed in five patients. Inappropriate interventions were seen in 10 patients. Predictors of appropriate firing were induction of ventricular tachycardia (VT) during electrophysiologic study (EPS) (84% vs. 44%, p = 0.024), detection of spontaneous VT (70% vs. 15%, p = 0.001), male versus female gender (91% vs. 65%, p = 0.04), and severe right ventricular dilation (39% vs. 0%, p = 0.013). Using multivariate analysis, VT induction during EPS was associated with increased risk for firing in ARVD/C patients; odds ratio 11.2 (95% confidence interval 1.23 to 101.24, p = 0.031).

Conclusions  Patients with ARVD/C have a high arrhythmia rate requiring appropriate ICD interventions. The ICD therapy appears to be well tolerated and important in the management of patients with ARVD/C.

Figures in this Article
ARVD/C

arrhythmogenic right ventricular dysplasia/cardiomyopathy

CI

confidence interval

EPS

electrophysiologic study

ICD

implantable cardioverter-defibrillators

LV

left ventricle/ventricular

OR

odds ratio

RV

right ventricle/ventricular

SCD

sudden cardiac death

VF

ventricular fibrillation

VT

ventricular tachycardia

Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is a myocardial disease characterized by ventricular arrhythmias in the setting of structural and functional abnormalities of the right ventricle (RV) due to replacement of myocardium by fatty and fibrous tissue (16). Diagnosis of ARVD/C is often difficult because there is no single test that can be used either to establish or exclude this diagnosis (79). However, the results of a history, physical examination, and a number of specific cardiac tests can be used to establish the diagnosis (2,1011). Patients with ARVD/C generally come to medical attention because of symptoms that result from arrhythmias arising in the RV. The most common presenting symptoms are palpitations, chest discomfort, near syncope, or syncope. The arrhythmias range from isolated premature ventricular beats to sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) that may lead to sudden death (34).

Once a diagnosis of ARVD/C is established, the most important management decision is whether to implant an implantable cardioverter-defibrillator (ICD) for treatment of sustained ventricular arrhythmias and prevention of sudden cardiac death (SCD) (12). This is a critically important decision because these are young patients with few or no symptoms who are expected to live many years with a device that is not complication-free. Furthermore, ICDs require replacement every five years, and the probability of lead failure increases with time. In addition, magnetic resonance imaging, which is valuable in the evaluation and follow-up of patients with ARVD/C, is presently contraindicated after ICD implantation.

Despite the importance of the decision to implant an ICD, remarkably few data exist concerning the safety and efficacy of ICD therapy in ARVD/C patients (1325). Therefore, the purpose of this study is to present the clinical characteristics and follow-up of a large series of ARVD/C patients who received ICDs. Particular attention is focused on defining the frequency and predictors of appropriate and inappropriate ICD therapies, the prognostic importance of experiencing VT storm, and the incidence of short-term and long-term complications in this patient population.

Patient population

This study was approved by the institutional review board of the Johns Hopkins University. The Johns Hopkins ARVD/C Program was established in 1995 to provide clinical care for patients with ARVD/C and to study this disease. At the initiation of this program, a registry was established consisting of the medical records of patients from North America diagnosed with ARVD/C. All those in the registry who had implantation of an ICD, a follow-up period of at least three months after implantation of the device, and documentation of the clinical outcome as of September 2002 were screened and invited to participate in the study. The population in the present study is comprised of all patients who agreed and signed the consent form. Files were reviewed for clinical and ICD records. Patients were contacted by telephone in the period from October through December 2002. A detailed questionnaire was completed, and in cases in which data were missing, documents and/or interrogations were sent to the registry for further evaluation and investigation.

Diagnosis of ARVD/C

The diagnosis of ARVD/C is based on the presence of certain major and minor diagnostic criteria employed by the international task force criteria (7) (Table le1). Each major criterion is scored 2 points, and each minor criterion is scored 1 point. The diagnosis is established by the presence of two major criteria or one major criterion plus two minor criteria or four minor criteria. The patients were classified as having “definitive” ARVD/C when they met the full criteria (4 points or more).

Table Grahic Jump Location
Table 1ARVD Diagnosis Criteria
Defibrillators

The patients in this study underwent placement of their initial ICD between July 1991 and February 2002. Implantation was performed through a thoracotomy with epicardial lead systems in three patients, all of whom were later implanted with transvenous systems. Most of the devices were third- and fourth-generation defibrillators with the capacity to provide antitachycardia and antibradycardia pacing; the devices had diagnostic memory and the ability to record and store electrocardiographic data, including intracardiac electrograms, for subsequent review. Programmed antitachycardia pacing was activated at the discretion of the cardiologist. Stored data were reviewed after all discharges. Interrogations were performed routinely every three to six months.

Classification of discharges and interpretation of intracardiac electrograms

When available, stored data were analyzed to classify the arrhythmias responsible for precipitating defibrillator discharges, according to the following definitions (26). Ventricular fibrillation or flutter was defined as ventricular arrhythmia with a cycle length of 240 ms or less. Ventricular tachycardia was defined as a regular (monomorphic) or irregular (polymorphic) ventricular arrhythmia with a cycle length of more than 240 ms. Defibrillator shocks were considered appropriate versus inappropriate on the basis of standard criteria (24). When complete ICD interrogation information was not available on a given patient, we relied on the outside the electrophysiologist interpretation of the ICD tracings. Electrical storm was defined according to the definition of Credner et al. (27) as the occurrence of VT or VF resulting in device intervention (antitachycardia pacing and/or shock delivery) three or more times within a 24-h period.

Statistical analysis

Continuous data are expressed as means ± SD. The cumulative probability of survival was determined by the Kaplan-Meier method (28), and differences in survival between groups were evaluated with the log-rank test. Multivariate analysis was performed using variables that in univariate analysis were found statistically significant as well as conditional logistic regression analysis adjusting for variables that may influence ICD firing. A value of p < 0.05 was considered statistically significant.

Patient population

Data from 87 patients with ICDs was screened for this study. Thirteen patients who did not meet the criteria for ARVD/C and 22 patients who were classified as “probable” ARVD/C (score = 3) (Table le1) were excluded from the study population. Ten additional patients were contacted but did not return a signed consent form and therefore were also excluded. Thus, the final patient population analyzed in this study consisted of 42 patients all classified as definitive ARVD/C, 22 (52%) of whom were male. Shown in (Figure 1) is the distribution in patients' age at the time of ICD implantation. The clinical characteristics of the patients in this study are summarized in (Table le2). The age range was 6 to 69 years (mean age, 36 ± 13 years, median 37 years); 28 patients (66%) were <41 years old. Seven patients were engaged in intense sport activity at the time of presentation, and 20 were involved in mild activity.

Grahic Jump Location
Figure 1

Age at time of defibrillator implantation in 42 patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy.

Table Grahic Jump Location
Table 2Predictors of Proper ICD Therapy
Table Footer Note*Left bundle-branch block type ventricular tachycardia (sustained and nonsustained) on ECG, Holter monitoring, or exercise testing. Frequent ventricular extrasystoles (>1,000/24 h) (Holter monitoring).
Implantation of ICD systems

All patients received multifunctional third- or fourth-generation ICDs. The implanted device was a single-chamber device in 27 (64%) patients and a dual-chamber device in 15 (36%) patients. The mean R-wave amplitude at the time of ICD implantation was 9.3 ± 4.6 mV. The R-wave amplitude in four patients was <5 mV (3.4 mV, 3.9 mV, 4.0 mV, and 4.3 mV). Appropriate sensing was achieved in all patients at the time of device implantation. The mean pacing threshold achieved at the time of device implantation was 0.85 ± 0.65 V. The pacing threshold was >1 V in five patients (1.3 V, 1.5 V, 2.0 V, 3.0 V, and 3.0 V). The mean defibrillation threshold was 13.5 ± 4.4 V. No patient had a defibrillation threshold >20 J.

In 4 (10%) patients, ICDs were implanted after either resuscitation from cardiac arrest or after experiencing an episode of sustained, spontaneous VT, and in 21 (50%) the reason was a syncopal episode. Of the remaining 17 patients, 15 had a history of one or more family sudden deaths (n = 7, of whom 5 had inducible VT on electrophysiologic testing), VT induction in electrophysiologic study (EPS) (n = 13), and left ventricular (LV) involvement (n = 2). Two patients had none of these high-risk markers. The major implantation reason and EPS findings in the study patients are summarized in (Table le3).

Table Grahic Jump Location
Table 3Main Indications for ICD Implantation in the Study Patients
Table Footer Note*EPS was performed in 41 patients in this study; one patient of the sudden death group did not have an EPS. †All monomorphic VTs in this group had left bundle-branch block pattern.

Among the remaining 17 (40%) patients, 7 had a history of one or more family sudden deaths, 3 had a family history of ARVD/C, 13 had VT induction in EPS, 2 had also LV involvement, and 1 had fat in biopsy. Two of these patients had none of these high-risk markers.

In this study, all but one patient had an EPS before device implantation. The EPS revealed induced sustained ventricular arrhythmia in 31 patients (74%) (polymorphic in 12 and monomorphic in 19). Eight patients underwent catheter ablation before or at the time of ICD implantation. Three patients had an ablation performed after the ICD implantation (0.1 to 5 months).

A complication at the time of implantation occurred in five (8%) patients.

Three patients required lead repositioning within several days after the initial implant procedure owing to inadequate R-wave amplitude. None had myocardial perforation and/or tamponade. One patient with an acute infection underwent system removal and replacement, whereas a second patient with subacute infection was treated successfully with antibiotics.

Patient follow-up

After a mean follow-up of 42 ± 26 months (range 4 to 135 months), one patient died of a brain malignancy, and in one patient who had end-stage disease with severe biventricular dysfunction and cavity dilation, heart transplantation was performed. There were no cases of late infections, myocardial perforation, or the development of a thromboembolism. During follow-up, ICD leads were replaced in another six patients either because of lead fracture or insulation damage (n = 4) or because of a decrease in R-wave amplitude (n = 2). These patients did not have more extensive disease. The ICD replacement was performed in 10 patients because of battery depletion.

ICD discharges

Thirty-three (78%) patients received a median of 4 (range 1 to 75) appropriate ICD interventions. Thirty patients were treated with defibrillation shocks and three with antitachycardia pacing. Ventricular tachycardia was the arrhythmia treated by the ICD in 92% of events. The patients were involved at different levels of exercise in 62% of ICD firing events. Shown in (Figure 2) is the interval between ICD implantation and the first appropriate ICD intervention (median 9 months, range 1 week to 66 months). The interval was two or more years in eight (19%) patients. Conversely, 15 (35%) patients had an initial appropriate discharge <6 months after implantation; in 12 of these 15 patients, there was at least one additional discharge (Figure 2). With an average follow-up of 3.5 years after implantation, the rate of appropriate discharges for the study group was 22% per year.

Grahic Jump Location
Figure 2

(A) Interval between implantation of the defibrillator and the first appropriate discharge in 33 patients. (B) Number of appropriate implantable cardioverter-defibrillator (ICD) discharges in 33 patients.

The ICD firing storms were observed in five patients, who experienced 6, 7, 9, 30, and 42 shocks within 24 h, respectively. Four of these patients had advanced ARVD/C with RV dysfunction. The interval between the ICD implant and storm was 1 to 45 months. The VT storm episode was the first ICD discharge in four of these patients. In two patients, no further ICD firing occurred with further follow-up; in the other three patients, one, four, and five single appropriate firings, respectively, occurred during follow-up. After the electrical storm episode, none of the patients subsequently presented with a second storm episode and none required either catheter ablation or cardiac transplantation for management of their ventricular arrhythmias.

Fifty-nine percent of all patients who experienced an ICD therapy reported that it occurred in association with exercise or other type of physical exertion. The ICD discharge occurred at rest in only one patient. The remainder of patients who experienced an ICD discharge (38%) were engaged in mild physical activity at the time of the device therapy.

(Table le4)summarizes the antiarrhythmic drug therapy use among the 33 patients who received an appropriate ICD therapy and those who did not. After an appropriate ICD therapy, the use of antiarrhythmic drugs increased. This was particularly observed among the five patients who experienced VT storm. Each of these patients was receiving combination antiarrhythmic therapy at last follow-up. At the time of most recent follow-up, 22 patients (52%) were receiving beta-blockers, 8 patients (19%) were receiving amiodarone, and 11 patients (26%) were receiving sotalol.

Table Grahic Jump Location
Table 4Medications of the Study Population

Ten (24%) patients experienced inappropriate interventions. In 9 of the 10 patients, there was also at least one appropriate discharge. The inappropriate discharges (all defibrillation shocks) were due to sinus tachycardia (in six patients), another type of supraventricular arrhythmia in two patients, and electrical noise resulting from lead fracture in two patients. Eight patients had only one inappropriate discharge. Seven patients had a single-lead device, whereas three had a dual-lead device. In the latter group the underlying rhythm was supraventricular tachycardia (in two patients) and lead disruption (in one patient).

During the follow-up period, nine (21%) patients did not experience an ICD firing. Two (22%) of these patients had a history of sustained symptomatic VT. Two (22%) had mild or moderate RV dysfunction, and none had severe RV dysfunction. Electrophysiology testing was performed in all nine patients and was positive in three (33%).

Predictors of appropriate ICD firings

Shown in Table le2 are the variables that were analyzed as potential predictors of ICD firing. Among them, four variables were identified as predictors: 1) induction of VT during EPS; 2) detection of spontaneous non-sustained VT on electrocardiogram, Holter monitoring, or exercise treadmill test; 3) RV moderate to severe dilation as compared with no dilation; and 4) male gender. The cumulative rates of first appropriate ICD discharge according to these four variables are shown in (Figure 3). Predictors of appropriate ICD firing were induction of VT during EPS (81% vs. 44%, respectively, p = 0.024), detection of spontaneous VT (70% vs. 15%, respectively, p = 0.001), male versus female gender (91% vs. 65%, respectively, p = 0.04), and severe RV dilation (39% vs. 0%, respectively, p = 0.013).

Grahic Jump Location
Figure 3

Cumulative rates of first appropriate discharges according to (A) gender and (B) detection of spontaneous ventricular tachycardia (VT) in electrocardiogram, Holter monitoring, or exercise treadmill test.

(C) Right ventricular (RV) dilation and (D) induction of VT during electrophysiologic study (EPS).

Conditional logistic regression analysis was performed using variables that in univariate analysis were statistically significant (Table le2) and adjusting for several variables that may influence ICD firing (signal-averaged electrocardiogram, age, beta-blockers usage, syncope, LV function, RV function). After adjustment for all of these variables, the induction of VT in EPS remained statistically significant (odds ratio [OR] 11.2, 95% confidence interval [CI] 1.23 to 101.24, p = 0.031). There was a trend toward RV dilation OR 3.41 (95% CI 0.88 to 14.21, p = 0.07) and, with male gender, OR 2.64 (95% CI 0.80 to 8.71, p = 0.11).

This study reports the outcome of 42 patients with ARVD/C who were treated with ICD therapy. The results of our study establish an important role for ICD therapy in the treatment of ventricular arrhythmias and possibly in the prevention of sudden death in patients with ARVD/C. Three findings of this study are of particular importance. First, more than three-quarters of ARVD/C patients received an appropriate ICD therapy during an average of 3.5 years of follow-up. The ICD proved reliable in sensing and terminating sustained ventricular arrhythmias, with no patients experiencing SCD. Second, this study identifies predictors of an appropriate ICD therapy; induction of VT during electrophysiologic testing, detection of nonsustained VT on noninvasive monitoring, male gender, and severe RV dilation. A third finding of this study is that ICD therapy is feasible and safe in patients with ARVD/C, with a low incidence of short-term and long-term complications.

Arrhythmogenic right ventricular dysplasia/cardiomyopathy is an uncommon but important cause of SCD, as most of these individuals are young. It is estimated that it accounts for up to one-fifth of all episodes of SCD that occur in patients below the age of 35 years (3). Although the role of ICD therapy for primary prevention of sudden death in patients with ischemic heart disease and for secondary prevention of SCD is well established (2934), few studies have examined the role of ICD therapy in patients with ARVD/C (1316). Those studies have enrolled relatively small numbers of patients. It is therefore not surprising that in the recently published joint recommendations of the American College of Cardiology and the American Heart Association, ARVD/C is not listed as a standard indication for placement of an ICD (12). Calkins and Marcus (3) have proposed that an ICD should be implanted in ARVD/C patients with an increased risk for SCD, based on the presence of a previous cardiac arrest, syncope due to VT, evidence for extensive RV disease, LV involvement, and presentation with polymorphic VT and RV apical aneurysm (which is associated with a genetic locus on chromosome 1q42-43). In our population, only five had severe LV dysfunction, three of whom had ICD firing.

In many patients in the present study, ICDs were implanted prophylactically for primary prevention of sudden death. This differs from clinical data and recommendations on ARVD/C derived from European experience (20,2425,31). It seems that the clinical approach and decision making regarding ICD implantation may be different in the U.S. Still, this is the first long-term study which implies that prophylactic ICD implantation for primary prevention of sudden death in ARVD/C is feasible.

Several previous studies have examined the safety and efficacy of ICD therapy in patients with ARVD/C. Tavernier et al. (16) reported that six of nine ARVD/C patients received appropriate firings after a follow-up of 32 ± 24 months. Inappropriate interventions were seen in five patients. Link et al. (14) reported that 8 of 12 patients with ARVD/C received appropriate therapy after a follow-up of 22 ± 13 months (range 1 to 45 months). They reported no short-term or long-term complications of RV lead placement and one sudden death at one month of follow-up. Breithardt et al. (13), in the largest series published so far, reported that 9 of 18 patients received appropriate therapy after a follow-up of 17 ± 11 months (range 1 to 40 months).

The results of the present study confirm and extend the findings of these previous reports of ICD therapy in ARVD/C patients. The 78% appropriate ICD discharge rate during a mean follow-up of 3.5 years in this study is remarkably similar to these previous reports. This rate is similar to the rate of appropriate ICD discharges reported for the long QT syndrome (33) but greater than has been reported for patients with coronary artery disease (31), hypertrophic cardiomyopathy (26), or idiopathic VF (13,32). The high ICD firing rate observed in this trial likely reflects a number of factors, including the clinical characteristics of the patient population, the prophylactic use of beta-blocker therapy in less than one-third of patients, and the small proportion of the patient population that were receiving class 1 and 3 antiarrhythmic agents after device implantation.

Although there was no statistically significant difference in beta-blockers usage between those who had an ICD firing and those who did not, there is a small trend towards a protective effect of beta-blockers confirming clinical experience. We believe that beta-blocker therapy should be considered prophylactically for all ARVD/C patients who undergo placement of an ICD.

The present study of ICD therapy in ARVD/C patients is unique because the larger patient population allowed us to examine predictors of receiving an appropriate ICD discharge and also to examine the incidence of experiencing VT storm. Multivariate analysis revealed that induction of VT during EPS was the most significant predictor for ICD firing in patients with definitive diagnosis of ARVD/C. It is notable that the interval between ICD implantation and a first appropriate ICD intervention exceeded two years in 19% of patients with appropriate discharges.

Five patients experienced an ICD firing storm between 1 and 45 months after implantation. Four of these patients had advanced ARVD/C with RV dysfunction. It is notable that these VT storms occurred on only a single occasion in these patients and were successfully controlled with alterations in antiarrhythmic drug therapy. None of these patients died during follow-up or required cardiac transplantation.

There are several potential complications of ICD therapy, which may be more likely to occur in ARVD/C patients as a result of the replacement of RV myocardium with fat and fibrotic tissue. These include an increased risk of: 1) perforation caused by thinning of the RV wall; 2) difficulty in lead placement owing to inadequate R-wave amplitudes or high pacing thresholds; 3) inadequate sensing or pacing during follow-up resulting from disease progression and deterioration of R-wave amplitudes and rising pacing thresholds; and 4) failure to terminate ventricular arrhythmias owing to rising defibrillation thresholds over time resulting from disease progression. Despite these concerns, it is somewhat reassuring that in this cohort of ARVD/C patients, the short-term and long-term risks of ICD therapy were similar to those in previous reports in non-ARVD/C patient populations (3536).

Currently, there is no firm evidence to determine whether a single chamber or a dual chamber ICD is preferable for patients with ARVD/C. For patients with concomitant sinus node dysfunction, a dual chamber ICD is clearly preferred. However, for patients with appropriate sinus node function and excellent AV nodal conduction, the potential benefits of better discrimination of atrial arrhythmias must be balanced against the long-term complications associated with increased hardware in patients. This is particularly relevant because most of these patients are young and will require more than 30 years of device therapy. Dual chamber devices allow for better discrimination between supraventricular arrhythmias and ventricular arrhythmias. This is especially important because exercise was identified as a common precipitant of arrhythmias in this and previous studies of ARVD/C (37).

Study limitations

There are several limitations to consider when interpreting the results of this study. First, the average follow-up in this patient series was 3.5 years. Because ARVD/C is a progressive disease, it is possible that additional complications of ICD systems may become apparent with longer follow-up. Secondly, sustained VT are not always sine qua non to sudden death, because they may be tolerated by patients with ARVD/C. We did not have complete information on the cycle lengths of all treated arrhythmias nor on the detailed symptoms that patients experienced at the time of all device therapies. When intracardiac tracings were unavailable for review, we relied on the outside the electrophysiologist interpretation of the tracing for classification of the device therapy as appropriate or inappropriate and also as to whether the arrhythmias were VT or VF. Although some may interpret the high rate of appropriate ICD interventions as a clear recommendation to implant ICDs in all ARVD/C patients, the results of this study do not allow us to draw this conclusion. It is important to note that a far more conservative approach to placement of ICDs in ARVD/C patients in Europe has resulted in a very low incidence of SCD. Hopefully, the results of ongoing multicenter clinical trials and genetic studies will help lead to firm recommendations concerning ICD implantation among ARVD/C patients.

The results of this study confirm that ICD therapy is safe and effective in patients with ARVD/C. The ICD provides lifesaving protection by effectively terminating ventricular tachyarrhythmias in patients with ARVD/C, many of whom are young. These results also represent an initial step toward developing better criteria for ICD implantation in patients with ARVD/C. The results of this study provide support for the high-risk markers proposed by Marcus (3,37) but also identify several new risk factors for experiencing an appropriate ICD intervention.

Marcus  F.I, Fontaine  G.H, Guiraudon  G; Right ventricular dysplasia. a report of 24 adult cases. Circulation. 65 1982:384-398.
CrossRef | PubMed
Corrado  D, Basso  C, Thiene  G; Spectrum of clinicopathologic manifestations of arrhythmogenic right ventricular cardiomyopathy/dysplasia. a multicenter study. J Am Coll Cardiol. 30 1997:1512-1520.
CrossRef | PubMed
Calkins  H, Marcus  F; Arrhythmogenic right ventricular dysplasia.Braunwald  E; Harrison's Advances in Cardiology. 2003 McGraw-Hill New York, NY:378-383.
Fontaine  G, Tonet  J, Frank  R; Ventricular tachycardia in arrhythmogenic right ventricular dysplasia.Zipes  D, Jalife  F; Cardiac Electrophysiology. From Cell to Bedside. 3rd edition 2000 WB Saunders Philadelphia, PA:546-555.
Marcus  F.I, Fontaine  G.F; Arrhythmogenic right ventricular dysplasia/cardiomyopathy. a review. Pacing Clin Electrophysiol. 18 1995:1298-1314.
CrossRef | PubMed
Gear  K, Marcus  F.I; Arrhythmogenic right ventricular dysplasia/cardiomyopathy. Circulation. 107 2003:e31
CrossRef | PubMed
McKenna  W.J, Thiene  G, Nava  A; Diagnosis of arrhythmogenic right ventricular dysplasia/cardiomyopathy. Br Heart J. 71 1994:218-228.
CrossRef
Marcus  F.I, Ott  P; Arrhythmogenic right ventricular dysplasia/cardiomyopathy.Berul  C.I, Towbin  J.A; Molecular Genetics of Cardiac Electrophysiology. 2000 Kluwer Academic Publishers Dordrecht:239-250.
Marcus  F.I; Update of arrhythmogenic right ventricular dysplasia. Card Electrophysiol Rev. 6 2002:54-56.
CrossRef | PubMed
Pinamonti  B, DiLenarda  A, Sinagra  G; Long-term evolution of right ventricular dysplasia/cardiomyopathy. Am Heart J. 129 1995:412-415.
CrossRef | PubMed
Lemery  R, Brugada  P, Janssen  J; Nonischemic sustained ventricular tachycardia. clinical outcome in 12 patients with arrhythmogenic right ventricular dysplasia. J Am Coll Cardiol. 14 1989:96-105.
CrossRef | PubMed
Gregoratos  G, Cheitlin  M.D, Conill  A; ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). J Am Coll Cardiol. 31 1998:1175-1209.
CrossRef | PubMed
Breithardt  G, Wichter  T, Haverkamp  W; Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy, long QT syndrome, or no structural heart disease. Am Heart J. 127 1994:1151-1158.
CrossRef | PubMed
Link  M.S, Wang  P.J, Haugh  C.J; Arrhythmogenic right ventricular dysplasia. clinical results with implantable cardioverter defibrillators. J Intervent Card Electrophysiol. 1 1997:41-48.
CrossRef
Niroomand  F, Carbucicchio  C, Tondo  C; Electrophysiological characteristics and outcome in patients with idiopathic right ventricular arrhythmia compared with arrhythmogenic right ventricular dysplasia. Heart. 87 2002:41-47.
CrossRef | PubMed
Tavernier  R, Gevaert  S, De Sutter  J; Long-term results of cardioverter-defibrillator implantation in patients with right ventricular dysplasia and malignant ventricular tachyarrhythmias. Heart. 85 2001:53-56.
CrossRef | PubMed
Dalla Volta  S, Battaglia  G, Zerbini  E; Auricularization of right ventricular pressure curve. Am Heart J. 61 1961:25-33.
CrossRef | PubMed
McKoy  G, Protonotarios  N, Crosby  A; Identification of a deletion in plakoglobin in arrhythmogenic right ventricular cardiomyopathy with palmoplantar keratoderma and woolly hair (Naxos disease). Lancet. 355 2000:2119-2149.
CrossRef | PubMed
Bauce  B, Nava  A, Rampazzo  A; Familial effort polymorphic ventricular arrhythmias in arrhythmogenic right ventricular cardiomyopathy map to chromosome 1q42-43. Am J Cardiol. 85 2000:573-579.
CrossRef | PubMed
Wichter  T, Borggreffe  M, Hawerkamp  W; Efficacy of antiarrhythmic drugs in patients with arrhythmogenic right ventricular disease. Circulation. 86 1992:29-37.
CrossRef | PubMed
Jaoude  S.A, Leclercq  J.F, Coumel  P; Progressive ECG changes in arrhythmogenic right ventricular disease. Eur Heart J. 17 1996:1717-1722.
CrossRef | PubMed
Oselladore  L, Nava  A, Buja  G; Signal-averaged electrocardiography in familial form of arrhythmogenic right ventricular cardiomyopathy. Am J Cardiol. 75 1995:1038-1041.
CrossRef | PubMed
Corrado D, Fontaine G, Marcus FI, et al. Arrhythmogenic right ventricular dysplasia/cardiomyopathy: the need for an International Registry. Circulation 2000;101:e101–6
Thiene  G, Nava  A, Corrado  D; Right ventricular cardiomyopathy and sudden death in young people. N Engl J Med. 318 1988:129-133.
CrossRef | PubMed
Basso  C, Thiene  G, Corrado  D; Arrhythmogenic right ventricular cardiomyopathy, dysplasia or myocarditis?. Circulation. 94 1996:983-991.
CrossRef | PubMed
Maron  B.J, Shen  W.K, Link  M.S; Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy. N Engl J Med. 342 2000:365-373.
CrossRef | PubMed
Credner  S.C, Klingenheben  T, Mauss  O; Electrical storm in patients with transvenous implantable cardioverter-defibrillators. incidence, management and prognostic implications. J Am Coll Cardiol. 32 1998:1909-1915.
CrossRef | PubMed
Kaplan  E.L, Meier  P; Nonparametric estimation from incomplete observations. J Am Stat Assoc. 53 1958:457-481.
CrossRef
Mirowski  M, Reid  P.R, Mower  M.M; Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med. 303 1980:322-324.
CrossRef | PubMed
Ezekowitz  J.A, Armstrong  P.W, McAlister  F.A; Implantable cardioverter defibrillators in primary and secondary prevention. a systematic review of randomised controlled trials. Ann Intern Med. 138 2003:445-452.
PubMed
Fontaine  G, Zenati  O, Tonet  J; The treatment of ventricular arrhythmias.Nava  A, Rossi  L, Thiene  G; Arrhythmogenic Right Ventricular Cardiomyopathy-Dysplasia. 1997 Elsevier Amsterdam, Netherlands:315-363.
Tebbenjohanns  J, Schumacher  B, Jung  W; Predictors of outcome in patients with implantable transvenous cardioverter defibrillators. Am Heart J. 127 1994:1086-1089.
CrossRef | PubMed
Gillis  A.M, Sheldon  R.S, Wyse  G; Clinical and electrophysiological predictors of ventricular tachyarrhythmia recurrence in patients with implantable cardioverter defibrillators. J Cardiovasc Electrophysiol. 14 2003:492-498.
CrossRef | PubMed
Silka  M.J, Kron  J, Dunnigan  A, Dick  M  2nd; Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society. Circulation. 87 1993:800-807.
CrossRef | PubMed
Dorwarth  U, Frey  B, Dugas  M; Transvenous defibrillation leads. high incidence of failure during long-term follow-up. J Cardiovasc Electrophysiol. 14 2003:38-43.
CrossRef | PubMed
Ellenbogen  K.A, Wood  M.A, Shepard  R.K; Detection and management of an implantable cardioverter defibrillator lead failure. incidence and clinical implications. J Am Coll Cardiol. 41 2003:73-80.
CrossRef | PubMed
Marcus  F.I; Right ventricular dysplasia. evaluation and management in relation to sports activities.Estes  N.A.M, Salem  D.N, Wang  P.J; Sudden Cardiac Death in the Athlete. 1998 Futura Armonk, NY:277-284.

Figures

Grahic Jump Location
Figure 1

Age at time of defibrillator implantation in 42 patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy.

Grahic Jump Location
Figure 2

(A) Interval between implantation of the defibrillator and the first appropriate discharge in 33 patients. (B) Number of appropriate implantable cardioverter-defibrillator (ICD) discharges in 33 patients.

Grahic Jump Location
Figure 3

Cumulative rates of first appropriate discharges according to (A) gender and (B) detection of spontaneous ventricular tachycardia (VT) in electrocardiogram, Holter monitoring, or exercise treadmill test.

(C) Right ventricular (RV) dilation and (D) induction of VT during electrophysiologic study (EPS).

Tables

Table Grahic Jump Location
Table 1ARVD Diagnosis Criteria
Table Grahic Jump Location
Table 2Predictors of Proper ICD Therapy
Table Footer Note*Left bundle-branch block type ventricular tachycardia (sustained and nonsustained) on ECG, Holter monitoring, or exercise testing. Frequent ventricular extrasystoles (>1,000/24 h) (Holter monitoring).
Table Grahic Jump Location
Table 3Main Indications for ICD Implantation in the Study Patients
Table Footer Note*EPS was performed in 41 patients in this study; one patient of the sudden death group did not have an EPS. †All monomorphic VTs in this group had left bundle-branch block pattern.
Table Grahic Jump Location
Table 4Medications of the Study Population

Interactive Graphics

Video

References

Marcus  F.I, Fontaine  G.H, Guiraudon  G; Right ventricular dysplasia. a report of 24 adult cases. Circulation. 65 1982:384-398.
CrossRef | PubMed
Corrado  D, Basso  C, Thiene  G; Spectrum of clinicopathologic manifestations of arrhythmogenic right ventricular cardiomyopathy/dysplasia. a multicenter study. J Am Coll Cardiol. 30 1997:1512-1520.
CrossRef | PubMed
Calkins  H, Marcus  F; Arrhythmogenic right ventricular dysplasia.Braunwald  E; Harrison's Advances in Cardiology. 2003 McGraw-Hill New York, NY:378-383.
Fontaine  G, Tonet  J, Frank  R; Ventricular tachycardia in arrhythmogenic right ventricular dysplasia.Zipes  D, Jalife  F; Cardiac Electrophysiology. From Cell to Bedside. 3rd edition 2000 WB Saunders Philadelphia, PA:546-555.
Marcus  F.I, Fontaine  G.F; Arrhythmogenic right ventricular dysplasia/cardiomyopathy. a review. Pacing Clin Electrophysiol. 18 1995:1298-1314.
CrossRef | PubMed
Gear  K, Marcus  F.I; Arrhythmogenic right ventricular dysplasia/cardiomyopathy. Circulation. 107 2003:e31
CrossRef | PubMed
McKenna  W.J, Thiene  G, Nava  A; Diagnosis of arrhythmogenic right ventricular dysplasia/cardiomyopathy. Br Heart J. 71 1994:218-228.
CrossRef
Marcus  F.I, Ott  P; Arrhythmogenic right ventricular dysplasia/cardiomyopathy.Berul  C.I, Towbin  J.A; Molecular Genetics of Cardiac Electrophysiology. 2000 Kluwer Academic Publishers Dordrecht:239-250.
Marcus  F.I; Update of arrhythmogenic right ventricular dysplasia. Card Electrophysiol Rev. 6 2002:54-56.
CrossRef | PubMed
Pinamonti  B, DiLenarda  A, Sinagra  G; Long-term evolution of right ventricular dysplasia/cardiomyopathy. Am Heart J. 129 1995:412-415.
CrossRef | PubMed
Lemery  R, Brugada  P, Janssen  J; Nonischemic sustained ventricular tachycardia. clinical outcome in 12 patients with arrhythmogenic right ventricular dysplasia. J Am Coll Cardiol. 14 1989:96-105.
CrossRef | PubMed
Gregoratos  G, Cheitlin  M.D, Conill  A; ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). J Am Coll Cardiol. 31 1998:1175-1209.
CrossRef | PubMed
Breithardt  G, Wichter  T, Haverkamp  W; Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy, long QT syndrome, or no structural heart disease. Am Heart J. 127 1994:1151-1158.
CrossRef | PubMed
Link  M.S, Wang  P.J, Haugh  C.J; Arrhythmogenic right ventricular dysplasia. clinical results with implantable cardioverter defibrillators. J Intervent Card Electrophysiol. 1 1997:41-48.
CrossRef
Niroomand  F, Carbucicchio  C, Tondo  C; Electrophysiological characteristics and outcome in patients with idiopathic right ventricular arrhythmia compared with arrhythmogenic right ventricular dysplasia. Heart. 87 2002:41-47.
CrossRef | PubMed
Tavernier  R, Gevaert  S, De Sutter  J; Long-term results of cardioverter-defibrillator implantation in patients with right ventricular dysplasia and malignant ventricular tachyarrhythmias. Heart. 85 2001:53-56.
CrossRef | PubMed
Dalla Volta  S, Battaglia  G, Zerbini  E; Auricularization of right ventricular pressure curve. Am Heart J. 61 1961:25-33.
CrossRef | PubMed
McKoy  G, Protonotarios  N, Crosby  A; Identification of a deletion in plakoglobin in arrhythmogenic right ventricular cardiomyopathy with palmoplantar keratoderma and woolly hair (Naxos disease). Lancet. 355 2000:2119-2149.
CrossRef | PubMed
Bauce  B, Nava  A, Rampazzo  A; Familial effort polymorphic ventricular arrhythmias in arrhythmogenic right ventricular cardiomyopathy map to chromosome 1q42-43. Am J Cardiol. 85 2000:573-579.
CrossRef | PubMed
Wichter  T, Borggreffe  M, Hawerkamp  W; Efficacy of antiarrhythmic drugs in patients with arrhythmogenic right ventricular disease. Circulation. 86 1992:29-37.
CrossRef | PubMed
Jaoude  S.A, Leclercq  J.F, Coumel  P; Progressive ECG changes in arrhythmogenic right ventricular disease. Eur Heart J. 17 1996:1717-1722.
CrossRef | PubMed
Oselladore  L, Nava  A, Buja  G; Signal-averaged electrocardiography in familial form of arrhythmogenic right ventricular cardiomyopathy. Am J Cardiol. 75 1995:1038-1041.
CrossRef | PubMed
Corrado D, Fontaine G, Marcus FI, et al. Arrhythmogenic right ventricular dysplasia/cardiomyopathy: the need for an International Registry. Circulation 2000;101:e101–6
Thiene  G, Nava  A, Corrado  D; Right ventricular cardiomyopathy and sudden death in young people. N Engl J Med. 318 1988:129-133.
CrossRef | PubMed
Basso  C, Thiene  G, Corrado  D; Arrhythmogenic right ventricular cardiomyopathy, dysplasia or myocarditis?. Circulation. 94 1996:983-991.
CrossRef | PubMed
Maron  B.J, Shen  W.K, Link  M.S; Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy. N Engl J Med. 342 2000:365-373.
CrossRef | PubMed
Credner  S.C, Klingenheben  T, Mauss  O; Electrical storm in patients with transvenous implantable cardioverter-defibrillators. incidence, management and prognostic implications. J Am Coll Cardiol. 32 1998:1909-1915.
CrossRef | PubMed
Kaplan  E.L, Meier  P; Nonparametric estimation from incomplete observations. J Am Stat Assoc. 53 1958:457-481.
CrossRef
Mirowski  M, Reid  P.R, Mower  M.M; Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med. 303 1980:322-324.
CrossRef | PubMed
Ezekowitz  J.A, Armstrong  P.W, McAlister  F.A; Implantable cardioverter defibrillators in primary and secondary prevention. a systematic review of randomised controlled trials. Ann Intern Med. 138 2003:445-452.
PubMed
Fontaine  G, Zenati  O, Tonet  J; The treatment of ventricular arrhythmias.Nava  A, Rossi  L, Thiene  G; Arrhythmogenic Right Ventricular Cardiomyopathy-Dysplasia. 1997 Elsevier Amsterdam, Netherlands:315-363.
Tebbenjohanns  J, Schumacher  B, Jung  W; Predictors of outcome in patients with implantable transvenous cardioverter defibrillators. Am Heart J. 127 1994:1086-1089.
CrossRef | PubMed
Gillis  A.M, Sheldon  R.S, Wyse  G; Clinical and electrophysiological predictors of ventricular tachyarrhythmia recurrence in patients with implantable cardioverter defibrillators. J Cardiovasc Electrophysiol. 14 2003:492-498.
CrossRef | PubMed
Silka  M.J, Kron  J, Dunnigan  A, Dick  M  2nd; Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society. Circulation. 87 1993:800-807.
CrossRef | PubMed
Dorwarth  U, Frey  B, Dugas  M; Transvenous defibrillation leads. high incidence of failure during long-term follow-up. J Cardiovasc Electrophysiol. 14 2003:38-43.
CrossRef | PubMed
Ellenbogen  K.A, Wood  M.A, Shepard  R.K; Detection and management of an implantable cardioverter defibrillator lead failure. incidence and clinical implications. J Am Coll Cardiol. 41 2003:73-80.
CrossRef | PubMed
Marcus  F.I; Right ventricular dysplasia. evaluation and management in relation to sports activities.Estes  N.A.M, Salem  D.N, Wang  P.J; Sudden Cardiac Death in the Athlete. 1998 Futura Armonk, NY:277-284.

Correspondence

Latest JACC CME

Continuing Medical Education through JACC is a convenient way to fulfill your CME requirements while learning important information about the latest advances in cardiovascular medicine.

April 2013- JACC CME Activity
Repeat Revascularization and Outcome

March 2013- JACC CME Activity
Extreme Lipoprotein(a) Levels and Improved Cardiovascular Risk Prediction

Feb 2013- JACC CME Activity
Results from the BARI 2D Trial

Jan 2013- JACC CME Activity
Prognosis Among Healthy Individuals Discharged With a Primary Diagnosis of Syncope

Dec 2012- JACC CME Activity
Incidence of Heart Failure or Cardiomyopathy After Adjuvant Trastuzumab Therapy for Breast Cancer

Nov 2012- JACC CME Activity
A Collaborative Analysis of Individual Patient Data From 10 Randomized Trials

Oct 2012- JACC CME Activity
Radiofrequency Ablation of Premature Ventricular Ectopy Improves the Efficacy of Cardiac Resynchronization Therapy in Nonresponders

Sept 2012- JACC CME Activity
Exercise and Pharmacological Treatment of Depressive Symptoms in Patients With Coronary Heart Disease

Aug 2012- JACC CME Activity
Reduction in Life-Threatening Ventricular Tachyarrhythmias in Statin-Treated Patients With Nonischemic Cardiomyopathy Enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy)

July 2012- JACC CME Activity
Relationship of Beta-Blocker Dose With Outcomes in Ambulatory Heart Failure Patients With Systolic Dysfunction

For previous CME quizzes, please follow this link to CardioSource Lifelong Learning and MOC.

 

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).
Submit a Comment
Submit a Comment

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Articles Related By Topic
Related Topics